MODEL
RSFC
Pilot operated, balanced piston sequence valve
SERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the
inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port
1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence),
up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in
the return line.
TECHNICAL DATA
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-202-007
Seal kit - Cartridge EPDM: 990-202-014
Seal kit - Cartridge Polyurethane: 990-002-002
Seal kit - Cartridge Viton: 990-202-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
J Capped Screw Adjustment
K Handknob
O Handknob with Panel Mount
W Hex Wrench Adjustment
Y Tri-Grip Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi (70
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70
bar) Standard Setting
C 150 - 6000 psi (10,5 - 420 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
N 60 - 800 psi (4 - 55 bar), 400 psi (28 bar)
Standard Setting
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/
RSFC
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
NOTES
Model Code Example: RSFCLANCONFIGURATION OPTIONS