MODEL
RDDT
Direct-acting relief valve, CE marked
SERIES 1 / CAPACITY: 75 L/min. / CAVITY: T-10A
Direct-acting relief cartridges are normally closed, pressure-limiting valves used to protect hydraulic components
from pressure transients. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open
to tank (port 2), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero leak,
dirt tolerant, immune to silting and are very fast.
The CE marked valve is a safety valve that meets the requirements of the European Directive for Pressurized
Devices (PED) 97/23/EC. The valve setting represents the excess operating pressure at which the valve opens.
Valve capacity can be determined from the performance curve. It shows an approved flow which depends on the
excess operating pressure. As a requirement of the PED, the system pressure at the maximum approved flow is a
maximum of 10% above the excess operating pressure.
TECHNICAL DATA
Response Time - Typical 2 ms
Maximum Valve Leakage at Reseat 0,7 cc/min.
Reseat >90% of setting
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-310-007
Seal kit - Cartridge Viton: 990-310-006
(Q)CONTROL
Q Capped and Lockwired
(A)ADJUSTMENT RANGE
A 100 - 210 bar (100 - 210 bar)
B 90 - 99 bar (90 - 99 bar)
C 315 - 422 bar (315 - 422 bar)
W 211 - 314 bar (211 - 314 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/RDDT
TECHNICAL FEATURES
Standard settings for preset valves include:
A adjustment range: 100 bar, 140 bar, 160 bar and 210 bar
W adjustment range: 250 bar
C adjustment range: 330 bar
Other settings are available upon request.
At this time RDDT and RDFT are the only Sun relief valves that are CE marked.
Each delivery contains a TÜV-Approval, which is a certification of the excess operating pressure and the approved flow, an EC Declaration of conformity and an
instructional manual.
Model Code Example: RDDTQANCONFIGURATION OPTIONS