MODEL
PVJA8
Pilot-operated, pressure reducing/relieving main stage with integral T-8A control
cavity and drain to port 4
SERIES 4 / CAPACITY: 320 L/min. / CAVITY: T-24A
(W)MINIMUM CONTROL PRESSURE
W 100 psi (7 bar)
D 25 psi (1,7 bar)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a 3-way, normally open modulating element, externally drained, that incorporates an integral pilot
control cavity. The pilot control cavity will accept any T-8A pressure control cartridge. The valve reduces a high
primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port
1 to tank (port 3). The pilot cartridge's setting determines the difference in pressure between reduced pressure (port
1) and the drain (port 4).
TECHNICAL DATA
Cavity T-24A
Series 4
Capacity 320 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,25 - 0,33 L/min.
Pilot Control Cavity T-8A
Valve Hex Size 41,3 mm
Valve Installation Torque 474 - 508 Nm
Seal kit - Cartridge Buna: 990024007
Seal kit - Cartridge Polyurethane: 990024002
Seal kit - Cartridge Viton: 990024006
Model Weight 1.35 kg.
sunhydraulics.com/model/
PVJA8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES
Model Code Example: PVJA8WNCONFIGURATION OPTIONS
c
2024 Sun Hydraulics 2 of 2
TECHNICAL FEATURES
Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
Pressure at port 4 should not exceed 5000 psi (350 bar).
Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
Maximum inlet pressure is determined by the bias spring. The D spring is tested with 2000 psi (140 bar) maximum differential pressure and the W spring is tested
with 5000 psi (350 bar) maximum inlet pressure.
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into
the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are
sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a
separate check valve to the circuit.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
PVJA Pilot-operated, pressure reducing/relieving valve with drain to port 4