(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 750 - 3000 psi (50 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 300 - 1500 psi (20 - 105 bar), 500 psi
(35 bar) Standard Setting
D 200 - 800 psi (14 - 55 bar), 400 psi (28
bar) Standard Setting
E 100 - 400 psi (7 - 28 bar), 200 psi (14
bar) Standard Setting
S 50 - 200 psi (3,5 - 14 bar), 100 psi (7
bar) Standard Setting
W 1000 - 4500 psi (70 - 315 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
TECHNICAL FEATURES
Note: This valve has no relieving capability. It should not be used in a dead-headed application. If the reduced pressure side of the circuit has very low leakage the
pressure may rise significantly. The pressure rise will vary from valve to valve.
This type of valve, PR*R, is a good replacement for an LP*C as a normally open, restrictive compensating element if a higher pressure drop across an orifice is
needed.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a
separate check valve to the circuit.
All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional
to pressure differential and inversely proportional to viscosity expressed in centistokes.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: PRFRLANCONFIGURATION OPTIONS