c
2019 Sun Hydraulics 1 of 2
MODEL
PPFB8
Pilot-operated, pressure reducing/relieving main stage with integral T-8A control
cavity
SERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a 3-way, normally open modulating element that incorporates an integral pilot control cavity. The pilot
control cavity will accept any T-8A pressure control cartridge. The valve reduces a high primary pressure at the inlet
(port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The pilot
cartridge's setting determines the difference in pressure between reduced pressure (port 1) and the tank (port 3).
TECHNICAL DATA
Cavity T-2A
Series 2
Capacity 80 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Pilot Control Cavity T-8A
Pilot Control Valve Installation Torque 27 - 33 Nm
Pilot Control Valve Hex Size 22,2 mm
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990202007
Seal kit - Cartridge EPDM: 990202014
Seal kit - Cartridge Polyurethane: 990002002
Seal kit - Cartridge Viton: 990202006
Model Weight 0.18 kg.
sunhydraulics.com/model/
PPFB8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES
c
2019 Sun Hydraulics 2 of 2
(W)MINIMUM CONTROL PRESSURE
W 100 psi (7 bar)
D 25 psi (1,7 bar)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
TECHNICAL FEATURES
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
Maximum inlet pressure is determined by the bias spring. The D spring is tested with 2000 psi (140 bar) maximum differential pressure and the W spring is tested
with 5000 psi (350 bar) maximum inlet pressure.
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into
the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are
sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a
separate check valve to the circuit.
All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When
considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
PPFB Pilot-operated, pressure reducing/relieving valve
Model Code Example: PPFB8WNCONFIGURATION OPTIONS