Fully adjustable needle valve with reverse flow check
Capacity:
Functional Group:
Products : Cartridges : Corrosion Resistant : Flow Control : 2 Port, Fully Adjustable
Needle with Reverse Flow Check
Model:
NCIA
Product Description
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow.
They are infinitely adjustable from fully closed up to the maximum orifice diameter. An
integral high-capacity check valve provides unrestricted flow from port 2 to port 1. They
are not pressure-compensated.
Technical Features
All 2-port flow control cartridges are physically and
functionally interchangeable (i.e. same flow path,
same cavity for a given frame size). However,
cartridge extension dimensions from the mounting
surface may vary.
Because needle valves are non-compensating
devices, the fixed orifice size will regulate flow
through the valve in proportion to the square root
of the pressure differential across ports 1 and 2.
Incorporates the Sun floating style construction to
minimize the possibility of internal parts binding
due to excessive installation torque and/or
cavity/cartridge machining variations.
Technical Data
U.S. Units Metric Units
Cavity T-18A
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min. 0,07 cc/min.
Series (from Cavity) Series 4
Valve Hex Size 1 5/8 in. 41,3 mm
Valve Installation Torque 350 - 375 lbf ft 465 - 500 Nm
Model Weight 2.10 lb 0,95 kg
Seal Kits Buna: 990-018-007
Seal Kits Viton: 990-018-006
NCIA-LAP
Control Cracking Pressure
External Material/Seal
Material
Standard Options
L Standard Screw Adjustment
A 4 psi (0,3 bar)
B 15 psi (1 bar)
C 30 psi (2 bar)
Z 1 psi (0,07 bar)
P Stainless/Buna-N
W Stainless/Viton
Explanation of Sun cartridge control options - US units.
Explanation of Sun cartridge control options - metric units.