Fully adjustable needle valve with reverse flow check
Capacity:
.09 in. (2,3 mm)
Functional Group:
Products : Cartridges : Flow Control : 2 Port : Fully Adjustable Needle Valve, With Reverse Flow Check
Model:
NCCC
Product Description
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully
closed up to the maximum orifice diameter. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1.
They are not pressure-compensated.
Technical Features
All 2-port flow control cartridges are physically and functionally
interchangeable (i.e. same flow path, same cavity for a given frame
size). However, cartridge extension dimensions from the mounting
surface may vary.
The sharp-edged orifice design minimizes flow variations due to
viscosity changes.
Because needle valves are non-compensating devices, the fixed orifice
size will regulate flow through the valve in proportion to the square
root of the pressure differential across ports 1 and 2.
Technical Data
U.S. Units Metric Units
Cavity T-13A
Capacity .09 in. 2,3 mm
Adjustment - Number of Counterclockwise Turns - Fully Closed to Fully Open 5
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 drops/min. 0,3 cc/min.
Series (from Cavity) Series 1
Valve Hex Size 7/8 in. 22,2 mm
Valve Installation Torque 30 - 35 lbf ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 108 lbf in. 12 Nm
Seal Kits - Cartridge Buna: 990-010-007
Seal Kits - Cartridge Viton: 990-010-006
Model Weight 0.31 lb. 0.14 kg.