Created on 12/09/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
MBGM
Balanced load control valve
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
Balanced load control valves combine a balanced modulating element with a reverse flow check. The check valve
allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating element
controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at Reseat See Technical Features
Check Cracking Pressure 1,7 bar
Seal kit - Cartridge Buna: 990-017-007
Seal kit - Cartridge Polyurethane: 990-017-002
Seal kit - Cartridge Viton: 990-017-006
(X)CONTROL
X Not Adjustable
(I)MINIMUM CONTROL PRESSURE
I 300 psi (20 bar)
E 75 psi (5 bar)
G 150 psi (10,5 bar)
K 450 psi (33 bar)
M 525 psi (36,7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/MBGM
TECHNICAL FEATURES
This valve has no relief function. Not even thermal expansion relief.
Maximum valve leakage at reseat for I, K, M ranges is 5 drops/min. (0,3 cc/min.) at 200 psi (14 bar) below cracking pressure; E and G ranges is 3 cubic in/min. (50
cc/min.) at 50 psi (3,5 bar) below cracking pressure.
E and G ranges are not meant for zero leak type applications.
This valve is balanced against load pressures and therefore exhibits self-compensation. Flow is controlled by the pilot pressure. Because of dynamic seals,
performance is best in the meter out mode with port 1 being the load and port 2 being tank.
Backpressure at port 2 directly opposes pilot pressure at port 3.
This valve is a physical replacement for a counterbalance valve but probably won't work well in a cross-piloted cylinder application. A low pilot ratio is needed for
machine stability and a balanced load control has an infinitely high pilot ratio.
Applications that use a separate pressure source to the pilot have been successful in providing smooth and stable load control.
All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
Sun load control and counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in
the circuit.
This valve has positive seals between all ports.
Model Code Example: MBGMXINCONFIGURATION OPTIONS
Created on 12/09/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.