c
2019 Sun Hydraulics 1 of 2
MODEL
LRFA
Normally closed, modulating element with pilot source from port 1
SERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
(X)CONTROL
X Not Adjustable
(H)BIAS PRESSURE
H 200 psi (14 bar)
D 50 psi (3,5 bar)
F 100 psi (7 bar)
G 150 psi (10,5 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA
Cavity T-2A
Series 2
Capacity 120 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Control Orifice Diameter 0,4 mm
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990202007
Seal kit - Cartridge Polyurethane: 990002002
Seal kit - Cartridge Viton: 990202006
Model Weight 0.22 kg.
sunhydraulics.com/model/
LRFA
Model Code Example: LRFAXHNCONFIGURATION OPTIONS
c
2019 Sun Hydraulics 2 of 2
TECHNICAL FEATURES
A tuning adjustment (models configured with an L control) is available to vary the pressure drop across the compensator to increase/decrease flow within +/-25% of
setting.
All ports will accept 5000 psi (350 bar).
Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel
components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of
Construction page located under TECH RESOURCES.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
RELATED MODELS
LRFA8 Normally closed, modulating element with integral T-8A control cavity and pilot source from port 1
LRFAL Tuneable, normally closed, modulating element with pilot source from port 1