c
2017 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
LRDA
Normally closed, modulating element with pilot source from port 1
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
(X)CONTROL
X Not Adjustable
(H)BIAS PRESSURE
H 200 psi (14 bar)
D 50 psi (3,5 bar)
F 100 psi (7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 60 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Control Orifice Diameter 0,4 mm
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Model Weight 0.12 kg.
snhy.com/
LRDA
Model Code Example: LRDAXHNCONFIGURATION OPTIONS
c
2017 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
TECHNICAL FEATURES
A tuning adjustment (models configured with an L control) is available to vary the pressure drop across the compensator to increase/decrease flow within +/-25% of
setting. This option is only available with the D spring option (50 psi [3,5 bar]).
All ports will accept 5000 psi (350 bar).
Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel
components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of
Construction page located under TECH RESOURCES.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
RELATED MODELS
LRDA8 Normally closed, modulating element with integral T-8A control cavity and pilot source from port 1
LRDAL Tuneable, normally closed, modulating element with pilot source from port 1