MODEL
LRDA
Normally closed, modulating element with pilot source from port 1
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
(X)CONTROL
X Not Adjustable
(H)BIAS PRESSURE
H 200 psi (14 bar)
D 50 psi (3,5 bar)
F 100 psi (7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 60 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Control Orifice Diameter 0,4 mm
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Model Weight 0.12 kg.
snhy.com/
LRDA
Model Code Example: LRDAXHNCONFIGURATION OPTIONS