MODEL
FVFA
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve
SERIES 4 / CAPACITY: 200 L/min. / CAVITY: T-24A
(X)CONTROL
X Not Adjustable
L Tuning Adjustment
(A)SETTING RANGE
A Replaceable Orifice .2 - 50 gpm (1 -
200 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA
Cavity T-24A
Series 4
Capacity 200 L/min.
Maximum Operating Pressure 350 bar
Nominal Vent Flow 0,75 L/min.
Maximum Input Flow 480 L/min.
Valve Hex Size 41,3 mm
Valve Installation Torque 474 - 508 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990024007
Seal kit - Cartridge EPDM: 990024014
Seal kit - Cartridge Polyurethane: 990024002
Seal kit - Cartridge Viton: 990024006
Model Weight 1.37 kg.
sunhydraulics.com/model/
FVFA
Model Code Example: FVFAXANCONFIGURATION OPTIONS
c
2019 Sun Hydraulics 2 of 2
TECHNICAL FEATURES
Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
Using a pressure control on port 4 will limit the pressure at the priority port (port 3). If pressure on the bypass port (port 2) exceeds the setting of the pressure
control, priority flow will be shut off and all the flow will go out the bypass port.
Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
Both priority and bypass flow are usable up to the system operating pressure.
Priority remains relatively constant regardless of variation in input flow.
Bypass flow is not available until priority flow requirements are satisfied, except when the valve is vented. When port 4 (vent) is open, all flow diverts to port 2 if
pressure at port 1 (inlet) is 150 psi (10,5 bar) or higher.
Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
The sharp-edged orifice design minimizes flow variations due to viscosity changes.
A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw.
Screw in (CW) to increase flow.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
FVFA8 Ventable, fixed orifice, bypass/restrictive, priority, flow control valve with integral T-8A control cavity