MODEL
FVCA
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve
SERIES 1 / CAPACITY: 23 L/min. / CAVITY: T-21A
(X)CONTROL
X Not Adjustable
L Tuning Adjustment
(A)SETTING RANGE
A Replaceable Orifice .1 - 6 gpm (0,4 - 23
L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 23 L/min.
Maximum Operating Pressure 350 bar
Nominal Vent Flow 0,75 L/min.
Maximum Input Flow 60 L/min.
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.16 kg.
sunhydraulics.com/model/
FVCA
Model Code Example: FVCAXANCONFIGURATION OPTIONS