c
2019 Sun Hydraulics 1 of 2
MODEL
FQEA
Fixed orifice, flow fuse valve
SERIES 2 / CAPACITY: 60 L/min. / CAVITY: T-5A
(X)CONTROL
X Not Adjustable
(A)SETTING RANGE
A Replaceable Orifice 1 - 15 gpm (4 - 60
L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA
Cavity T-5A
Series 2
Capacity 60 L/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 50 cc/min.@70 bar
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990203007
Seal kit - Cartridge Viton: 990203006
Model Weight 0.19 kg.
sunhydraulics.com/model/
FQEA
TECHNICAL FEATURES
Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
Valve closes when flow from port 1 to port 2 exceeds the setting of the valve. Valve resets when pressures at port 1 and port 2 are equal.
Flow setting should be at least 25% above maximum normal system flow. Customer must specify flow when ordering valve.
These are spool type valves, therefore there is leakage. Some actuator drift may occur.
Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP or /LH (see CONFIGURATION
section). For further details, please see the Materials of Construction page under TECHNICAL RESOURCES.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
Model Code Example: FQEAXANCONFIGURATION OPTIONS
c
2019 Sun Hydraulics 2 of 2
PERFORMANCE CURVES