c
2019 Sun Hydraulics 1 of 2
MODEL
FQBA
Fixed orifice, flow fuse valve
CAPACITY: 8,5 L/min. / CAVITY: T-162A
(X)CONTROL
X Not Adjustable
(A)SETTING RANGE
A Replaceable Orifice .5 - 2.25 gpm (2 -
8,5 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA
Cavity T-162A
Series 0
Capacity 8,5 L/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Valve Hex Size 19,1 mm
Valve Installation Torque 27 - 33 Nm
Seal kit - Cartridge Buna: 990162007
Seal kit - Cartridge EPDM: 990162014
Seal kit - Cartridge Polyurethane: 990162002
Seal kit - Cartridge Viton: 990162006
Model Weight 0.07 kg.
sunhydraulics.com/model/
FQBA
TECHNICAL FEATURES
Customer must specify a flow rating. Factory set flow ratings are within +/- 15% of the requested setting.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
Valve closes when flow from port 1 to port 2 exceeds the setting of the valve. Valve resets when pressures at port 1 and port 2 are equal.
Flow setting should be at least 25% above maximum normal system flow. Customer must specify flow when ordering valve.
These are spool type valves, therefore there is leakage. Some actuator drift may occur.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: FQBAXANCONFIGURATION OPTIONS
c
2019 Sun Hydraulics 2 of 2