MODEL
FDBA
Fully adjustable pressure compensated flow control valve with reverse flow
check
SERIES 1 / CAPACITY: 23 L/min. / CAVITY: T-13A
Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable
from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from
port 2 to port 1.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Adjustment - Number of Counterclockwise Turns - Fully Closed to Fully Open 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-010-007
Seal kit - Cartridge Polyurethane: 990-010-002
Seal kit - Cartridge Viton: 990-010-006
(L)CONTROL
L Standard Screw Adjustment
H Calibrated Handknob with Detent Lock
K Handknob
Y Tri-Grip Handknob
(A)ADJUSTMENT RANGE
A .1 - 6 gpm (0,4 - 23 L/min.)
B .1 - 2 gpm (0,4 - 8 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
snhy.com/
FDBA
TECHNICAL FEATURES
All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge
extension dimensions from the mounting surface may vary.
A balanced adjustment mechanism allows for easy adjustment even at high pressures.
The sharp-edged orifice design minimizes flow variations due to viscosity changes.
Minimum leakage is .1 gpm (0,4 L/min) when the adjustment mechanism is turned to the shut-off position.
Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
PERFORMANCE CURVES
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
NOTES
Model Code Example: FDBALANCONFIGURATION OPTIONS