MODEL
FCAB
Fixed orifice pressure compensated flow control valve with reverse flow check
SERIES 2 / CAVITY: T-5A
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA
Cavity T-5A
Series 2
Maximum Operating Pressure 350 bar
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990203007
Seal kit - Cartridge Viton: 990203006
Model Weight 0.17 kg.
(X)CONTROL
X Not Adjustable
K Handknob
L Tuning Adjustment
(A)SETTING RANGE
A Replaceable Orifice 10 - 200 in³/min.
(0,16 - 3,3 L/min.)
B Permanent Orifice 10 - 200 in³/min.
(0,16 - 3,3 L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/FCAB
TECHNICAL FEATURES
Customer must specify a flow rating.
Accurate pressure compensated control requires that a constant pressure differential be maintained across the valve.
The sharp-edged orifice design minimizes flow variations due to viscosity changes.
The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
Model Code Example: FCABXANCONFIGURATION OPTIONS