MODEL
DWDA
3-way, direct-acting, solenoid-operated directional poppet valve
SERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
X-Control M-Control
D-Control
L-Control
T-Control
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, poppet-style directional valve. The valve is
normally open between port 1 and port 2 with port 3 blocked. Energizing the valve connects port 2 to 3 and blocks
port 1. All flow paths are bidirectional and blocked paths are blocked in both directions. Due to the poppet style
construction, this valve has extremely low leakage.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Switching Frequency 15000 cycles/hr
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-411-007
Seal kit - Cartridge Viton: 990-411-006
(X)CONTROL
X No Manual Override
M Manual Override (Standard)
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
T Twist (Momentary) Manual Override
(A)POPPET CONFIGURATION
A Normally Open 1 to 2, Closed 2 to 3
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DWDA
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is
not compatible with weatherized coils.
This valve is suitable for load holding applications on port 3 only. In the event of power failure, the valve would spring closed.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DWDAXANCONFIGURATION OPTIONS