Created on 12/10/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 3
MODEL
DWDA
3-way, direct-acting, solenoid-operated directional poppet valve
SERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
X-Control M-Control
D-Control
L-Control
T-Control
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, poppet-style directional valve. The valve is
normally open between port 1 and port 2 with port 3 blocked. Energizing the valve connects port 2 to 3 and blocks
port 1. All flow paths are bidirectional and blocked paths are blocked in both directions. Due to the poppet style
construction, this valve has extremely low leakage.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Switching Frequency 15000 cycles/hr
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-411-007
Seal kit - Cartridge Viton: 990-411-006
(X)CONTROL
X No Manual Override
M Manual Override (Standard)
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
T Twist (Momentary) Manual Override
(A)POPPET CONFIGURATION
A Normally Open 1 to 2, Closed 2 to 3
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DWDA
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is
not compatible with weatherized coils.
This valve is suitable for load holding applications on port 3 only. In the event of power failure, the valve would spring closed.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DWDAXANCONFIGURATION OPTIONS
Created on 12/10/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 3
assembly has a mechanical life expectancy of approximately 7,000 cycles.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a
factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes
that will affect the function of the cartridge.
A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
The solenoid's unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
Coil connector options offer ratings up to IP69K. See individual coil product pages for details. Additional weatherized coils and kits are available for more complete
environmental protection.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED ACCESSORIES
Created on 12/10/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 3 of 3
773-812 12 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-814 14 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-824 24 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-828 28 VDC weatherized coil with Metri-Pack, Series 150-2M connector
773-836 36 VDC weatherized coil with Metri-Pack, Series 150-2M connector
991-055 T-11A cavity, weatherized coil seal kit
991-225 Momentary/twist operation, manual override control kit, T control
991-226 Detent/lock operation, manual override control kit, L control
991-227 Dual twist/lock operation, manual override control kit, D control