MODEL
DSIY
3-way, 2-position, vent-to-shift diverter valve, normally open
SERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-34A
(X)CONTROL
X Not Adjustable
(E)MINIMUM CONTROL PRESSURE
E 75 psi (5 bar)
C 30 psi (2 bar)
D 50 psi (3,5 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This vent-to-shift diverter valve is a 2-position, 3-way cartridge that is normally open from port 3 to port 4. When
port 1 is vented, the pressure differential between port 3 and port 1 exceeds the spring force causing the valve to
shift, thereby connecting port 3 to port 2.
TECHNICAL DATA
Cavity T-34A
Series 4
Capacity 480 L/min.
Maximum Operating Pressure 350 bar
Nominal Vent Flow 0,60 L/min.
Valve Hex Size 41,3 mm
Valve Installation Torque 474 - 508 Nm
Seal kit - Cartridge Buna: 990034007
Seal kit - Cartridge Polyurethane: 990034002
Seal kit - Cartridge Viton: 990034006
Model Weight 1.58 kg.
sunhydraulics.com/model/DSIY
Model Code Example: DSIYXENCONFIGURATION OPTIONS