c
2025 Sun Hydraulics 1 of 2
MODEL
DRAX
2-way, pilot-to-shift directional valve with drain to port 4 - normally closed
SERIES 1 / CAPACITY: 2 L/min. / CAVITY: T-21A
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
(A)ADJUSTMENT RANGE
A 1000 - 3000 psi (70 - 210 bar), 1000 psi
(70 bar) Standard Setting
C 2000 - 6000 psi (140 - 420 bar), 2000
psi (140 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
The normally-closed, direct-acting 2-way directional cartridge with external drain is a pilot unloading valve used to
sense pressure in one circuit to switch or unload a valve in a different circuit. When pressure at port 1 exceeds the
setting of the valve, the spool shifts to connect port 2 to port 3.
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 2 L/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at Reseat 20 drops/min.
Reseat >85% of setting
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.20 kg.
sunhydraulics.com/model/DRAX
TECHNICAL FEATURES
The pilot area (port 1) and the spring chamber drain (port 4) are positively sealed.
There is spool leakage between the work ports (ports 2 and 3)of less than 20 drops/min (1,4 cc/min).
The valve is designed to not modulate and is the equivalent of a hydraulic pressure switch.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
Model Code Example: DRAXLANCONFIGURATION OPTIONS
c
2025 Sun Hydraulics 2 of 2
PERFORMANCE CURVES