c
2024 Sun Hydraulics 1 of 2
MODEL
DPCP
3-way, pilot-operated, directional valve with drain to port 4 (1 to 2 open, 3
blocked)
SERIES 2 / CAPACITY: 60 L/min. / CAVITY: T-22A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot-operated, 3-way directional cartridges (1 to 2 open, 3 blocked) are switching devices typically used in
moderate flow circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or
logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
TECHNICAL DATA
Cavity T-22A
Series 2
Capacity 60 L/min.
Maximum Operating Pressure 350 bar
Factory Pressure Settings Established at 15 L/min.
Control Pilot Flow 0,16 - 0,25 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Adjustment - No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990022007
Seal kit - Cartridge Polyurethane: 990022002
Seal kit - Cartridge Viton: 990022006
Model Weight 0.34 kg.
sunhydraulics.com/model/
DPCP
c
2024 Sun Hydraulics 2 of 2
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000
psi (70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
TECHNICAL FEATURES
Port 4 can be blocked to prevent the valve from shifting.
Port 3 can be used as a work port.
Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
Pressure at port 4 is directly additive to the setting of the valve.
This valve is not bistable; it is capable of modulating between the two positions shown.
Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve
setting. If this is a problem, the direct acting version of this valve would be a solution.
Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: DPCPLANCONFIGURATION OPTIONS