c
2019 Sun Hydraulics 1 of 2
MODEL
DPBN
2-way, pilot-operated, directional valve with drain to port 4 - normally closed
SERIES 1 / CAPACITY: 28 L/min. / CAVITY: T-21A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Normally closed, pilot-operated, 2-way directional cartridges are switching devices typically used in moderate-flow
circuits. They can be used by themselves or to actuate larger pilot-operated directional cartridges or logic
cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 28 L/min.
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,11 - 0,16 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Adjustment - No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.19 kg.
snhy.com/
DPBN
c
2019 Sun Hydraulics 2 of 2
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
J 25 - 1500 psi (1,7 - 105 bar), 1000 psi
(70 bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000
psi (70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
TECHNICAL FEATURES
Port 4 can be blocked to prevent the valve from shifting.
Port 3 can be used as a work port.
Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
Pressure at port 4 is directly additive to the setting of the valve.
This valve is not bistable; it is capable of modulating between the two positions shown.
Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve
setting. If this is a problem, the direct acting version of this valve would be a solution.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: DPBNLANCONFIGURATION OPTIONS