c
2026 Sun Hydraulics 1 of 2
MODEL
DOJDDOJD
Normally open, balanced poppet, logic element - vent-to-close
SERIESSERIES 4 / 4 / CAPACITY:CAPACITY: 480 L/min. / 480 L/min. / CAVITY:CAVITY: T-19A T-19A
(E)(E)CONTROLCONTROL
EE External 4-SAE Drain Port
(H)(H)MINIMUM PILOT PRESSUREMINIMUM PILOT PRESSURE
HH 300 psi (20 bar)
(N)(N)SEAL MATERIALSEAL MATERIAL
NN Buna-N
VV Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This is a normally open, balanced poppet, switching element. When the external vent port is
blocked, the poppet remains in the open position. Venting the external port shifts it to the
closed position, provided there is sufficient pressure at port 3.
TECHNICAL DATATECHNICAL DATA
Cavity T-19A
Series 4
Capacity 480 L/min.
Maximum Operating Pressure 350 bar
Minimum Pilot Pressure Required to Shift Valve 20 bar
Control Pilot Flow See Performance Data
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Pilot Volume Displacement 2,8 cc
Valve Hex Size 41,3 mm
Valve Installation Torque 474 - 508 Nm
Seal kit - Cartridge Buna: 990019007
Seal kit - Cartridge Polyurethane: 990019002
Seal kit - Cartridge Viton: 990019006
Model Weight 1.38 kg.
sunhydraulics.com/model/
DOJD
Model Code Example: DOJDArrayModel Code Example: DOJDArrayCONFIGURATION OPTIONSCONFIGURATION OPTIONS
c
2026 Sun Hydraulics 2 of 2
TECHNICAL FEATURESTECHNICAL FEATURES
Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2, with the external drain
port open and a minimum pilot pressure of 300 psi (20 bar).
The external -4 SAE vent port may be directly connected to a pilot switching valve. The pilot valve should have a leakage rate of less
than 10 drops/min (0,7 cc/min). and be able to satisfy the pilot flow requirements. Sun model DAA*-*** solenoid pilot valve is ideal
for this application.
Valve will open when the pilot pressure falls below 145 psi (10 bar).
These valves are hydraulically balanced between port 1 and port 2.
Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
Port 1 and port 2 are fully sealed from port 3.
All ports will accept 5000 psi (350 bar).
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation
torque and/or cavity/cartridge machining variations.
PERFORMANCE CURVESPERFORMANCE CURVES