MODEL
DMDA
3-way, solenoid-operated directional spool valve
SERIES 1 / CAPACITY: 45 L/min. / CAVITY: T-11A
X-Control, A-Spool X-Control, B-Spool
X-Control, N-Spool X-Control, P-Spool
X-Control, R-Spool
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool directional valve.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 80 cc/min.@210 bar
Switching Frequency 15000 cycles/hr
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-411-007
Seal kit - Cartridge EPDM: 990-411-014
Seal kit - Cartridge Viton: 990-411-006
(X)CONTROL
X No Manual Override
M Manual Override
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
T Twist (Momentary) Manual Override
(A)SPOOL CONFIGURATION
A Normally Open 1 to 2, Closed 2 to 3
N Normally Open 2 to 3, Closed 1 to 2
B Normally Open 1 to 2, Closed 2 to 3,
Closed Transition
P Normally Open 1 to 3, Closed 1 to 2
R Normally Open 2 to 3, Closed 1 to 2,
Closed Transition
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DMDA
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
Spools B and R are closed in the transition between their two positions. This results in a higher performance limit at the expense of lower capacity. When used as
pilot controls, where capacity is not a factor, the closed transition will provide faster and more consistent response times.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control
assembly has a mechanical life expectancy of approximately 7,000 cycles.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DMDAXANCONFIGURATION OPTIONS