MODEL
DBAL
3-way, solenoid-operated directional spool valve - pilot capacity
SERIES P / CAPACITY: 1 L/min. / CAVITY: T-9A
X-Control, H-Spool X-Control, C-Spool
M or S-Control, C-Spool M or S-Control, H-Spool
D-Control, C-Spool D-Control, H Spool
L-Control, C-Spool L-Control, H-Spool
T-Control, C-Spool T-Control, H-Spool
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool pilot valve used to pilot other
full-flow valves. The valve is normally open between port 1 and port 2 or port 1 and port 3 and all flow paths are
bidirectional.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Switching Frequency 15000 cycles/hr
Manual Override Force Requirement 66 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-009-007
Seal kit - Cartridge EPDM: 990-309-114
Seal kit - Cartridge Polyurethane: 990-009-002
Seal kit - Cartridge Viton: 990-009-006
(X)CONTROL
X No Manual Override
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
M Manual Override
T Twist (Momentary) Manual Override
(H)SPOOL CONFIGURATION
H Normally Open 1 to 2, Closed 1 to 3
C Normally Open 1 to 3, Closed 1 to 2
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DBAL
TECHNICAL FEATURES
Model DBAL integrates the same coil, connector, and manual override options that are currently available on Series 1 valves. The DBAL is interchangeable with the
DBAA except for the external coil dimensions and higher coil wattage.
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DBALXHNCONFIGURATION OPTIONS