TECHNICAL FEATURES
This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size).
However, cartridge extension dimensions from the mounting surface may vary.
Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination
and the valve should be replaced.
Sealed pilot for use in circuits where cross port leakage is undesirable.
Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
This valve is identical to a CKED except for a high performance seal on the pilot piston.
For models with manual load release control option, turn load release clockwise to release load.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES