c
2019 Sun Hydraulics 1 of 2
MODEL
CKCS
5:1 pilot ratio, pilot-to-open check valve with sealed pilot
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
(X)CONTROL
X Standard Pilot
B External 1/4 BSPP Pilot Port, Port 3
blocked
C Manual Load Release - Tamper
Resistant
E External 4-SAE Pilot Port, Port 3
Blocked
L Manual Load Release
P External 1/4 NPTF Port, Port 3 blocked
(C)CRACKING PRESSURE
C 30 psi (2 bar)
A 4 psi (0,3 bar)
B 15 psi (1 bar)
D 50 psi (3,5 bar)
E 75 psi (5 bar)
F 100 psi (7 bar)
Z 1 psi (0,07 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flow
from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will
open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the
load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 60 L/min.
Pilot Ratio 5:1
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Viton: 990011006
Model Weight 0.13 kg.
sunhydraulics.com/model/
CKCS
Model Code Example: CKCSXCNCONFIGURATION OPTIONS
c
2019 Sun Hydraulics 2 of 2
TECHNICAL FEATURES
This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size).
However, cartridge extension dimensions from the mounting surface may vary.
For models with manual load release control option, turn load release clockwise to release load.
Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination
and the valve should be replaced.
Sealed pilot for use in circuits where cross port leakage is undesirable.
Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel
components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of
Construction page located under TECH RESOURCES.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES