Created on 12/08/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
CKCG
Vented pilot-to-open check valve with external pilot port, standard pilot, stem
seal, and Delrin seat
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is vented. It allows free flow
from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot
port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the
load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the
vent (port 3).
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 60 L/min.
Pilot Ratio 3:1
Maximum Operating Pressure 175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Model Weight 0.12 kg.
(S)CONTROL
S External 4-SAE Pilot Port, Vent to Port
3
V External 1/4 NPTF Pilot Port, Vent to
Port 3
(C)CRACKING PRESSURE
C 30 psi (2 bar)
B 15 psi (1 bar)
D 50 psi (3,5 bar)
E 75 psi (5 bar)
F 100 psi (7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/
CKCG
Model Code Example: CKCGSCNCONFIGURATION OPTIONS
Created on 12/08/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
TECHNICAL FEATURES
There is a positve seal between ports 2 and 3.
These valves should be considered service items only. New applications should use valves from the CV*V family.
This valve has a proportional pressure reducing characteristic that limits the pressure developed at port 1 to about 75% of the pressure at port 2.
Pilot pressure as low as 15 psi (1 bar) higher than the pressure at the vent can prevent the valve from closing.
Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different
pilot/vent configuration.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES