c
2024 Sun Hydraulics 1 of 2
MODEL
CDAA
Back-to-back check/shuttle valve with signal external
SERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-13A
(B)CONTROL
B External 1/4 BSPP Port
E External 4-SAE Port
(B)CRACKING PRESSURE
B 15 psi (1 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
The back-to-back check valve combines two simple check valves into a single cartridge. It connects the higher of
two work ports to the signal or common port. The signal is sensed at an external port located in the hex-end of the
cartridge.
TECHNICAL DATA
Cavity T-13A
Series 1
Capacity 10 L/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,3 cc/min.
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge Polyurethane: 990010002
Seal kit - Cartridge Viton: 990010006
Model Weight 0.09 kg.
sunhydraulics.com/model/
CDAA
TECHNICAL FEATURES
Back-to-back check cartridges feature hardened, spherically lapped, guided poppets and a lightly stressed helical spring that result in excellent wear characteristics
and extremely low leakage rates.
The back-to-back checks do not provide a means of lowering a signal. They will trap a high signal if the load pressures drop to a lower pressure. Some means of
bleeding off the signal should be provided.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
Model Code Example: CDAABBNCONFIGURATION OPTIONS
c
2024 Sun Hydraulics 2 of 2
PERFORMANCE CURVES