2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
CCCA
Standard capacity counterbalance valve without pilot assist
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free
flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1
to port 2.
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 60 L/min.
Pilot Ratio Zero
Maximum Recommended Load Pressure at Maximum Setting 215 bar
Maximum Setting 280 bar
Factory Pressure Settings Established at 30 cc/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at Reseat 0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75
Operating Characteristic Standard
Reseat >85% of setting
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Model Weight 0.16 kg.
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
J Capped Screw Adjustment
(H)FUNCTIONAL SETTING RANGE
H 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi
(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -
280 bar w/ 0,3 bar Check), 3000 psi
(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
snhy.com/
CCCA
Model Code Example: CCCALHNCONFIGURATION OPTIONS
Created on 12/14/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
B 400 - 1500 psi w/4 psi Check (28 - 105
bar w/ 0,3 bar Check), 1000 psi (70
bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -
105 bar w/ 1,7 bar Check), 1000 psi (70
bar) Standard Setting
TECHNICAL FEATURES
Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
Turn adjustment clockwise to decrease setting and release load.
Full clockwise setting is less than 200 psi (14 bar).
These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
Backpressure at port 2 is directly additive to the relief setting of the valve.
Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel
components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of
Construction page located under TECH RESOURCES.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
CCCAX Fixed setting standard capacity counterbalance valve without pilot assist