hydraulics
www.sunhydraulics.com ©2019 Sun Hydraulics Pub.#999-901-717
sunhydraulics.com/model/DNB*
DNB*
5000/3000 psi (350/210 bar)
T-30A cavity
4WAY, 2POSITION
SOLENOIDOPERATED
DIRECTIONAL SPOOL VALVES
TABLE OF CONTENTS
Technical Features 2
Model Congurations & Options 3
Technical Specications 4
Performance Curves 5
Dimensional Drawings 8
Cavity Drawing & Tooling 9
Additional Information 10
Sun FLeX Series Solenoid Valves
HIGH RELIABILITY
Designed & tested to 10-million
operational cycles at full rated pressure
ZINCNICKEL COATING STANDARD
Oers 1,000-hour salt fog protection
USE WITH ANY OF THREE COILS
Energy-saving (3000 psi), high-power
(5000 psi) & hazardous location coils
DNBD-XC*
3000 psi (210 bar)
DNBF-XC*
5000 psi (350 bar)
DNBF-XD*
5000 psi (350 bar)
DNBD-XD*
3000 psi (210 bar)
DNBF-XE*
5000 psi (350 bar)
DNBD-XE*
3000 psi (210 bar)
DNBF-XN*
5000 psi (350 bar)
DNBD-XN*
3000 psi (210 bar)
DNBF-XT*
5000 psi (350 bar)
DNBD-XT*
3000 psi (210 bar)
DNBF-XV*
5000 psi (350 bar)
DNBD-XV*
3000 psi (210 bar)
©2019 Sun Hydraulics2 www.sunhydraulics.com
FLeX Series
DNB*-XC*
DNB*-XD*
DNB*-XE*
DNB*-XN*
DNB*-XT*
DNB*-XV*
All FLeX Series valves incorporate the Sun oating-style construction to minimize the possibility of internal
parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Designed and tested to 10-million operational cycles at full rated pressure.
Exceeds the new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
Zinc-nickel plating standard for 1000-hour salt fog protection.
Designed using CFD simulation for optimized geometries.
A wide variety of coil termination and voltage options are available, with and without surge protection. See the
CONFIGURATION section.
Coil connector options oer ratings up to IP69K. See individual coil product pages for details.
The 3000-psi (210-bar) DNBD valves use the low-power (17-W) coils; the 5000-psi (350-bar) DNBF valves use the
high-power (25-W) coils. Note that all DNB* valves can be used with the hazardous location coils. See table on
page 3.
TECHNICAL FEATURESS
DNB*
SERIES 0, CAVITY: T-30A4WAY, 2POSITION SOLENOIDOPERATED
DIRECTIONAL SPOOL VALVE
TECHNICAL FEATURES
The 4-way, 2-position directional spool valves are direct
acting. They comprise a hex body (3), solenoid with coil
(2), spool (4), and a coil nut (1).
DNB*-XC* (C Spool)
Function: When de-energized, the spool (4) creates a
blocked ow path in all directions. When energized, the
spool (4) creates a bidirectional open ow path from 3 to
2 and 4 to 1.
DNB*-XN* (N Spool)
Function: When de-energized, the spool (4) creates a
bidirectional open ow path from 3 to 2 and 4 to 1. When
energized, the spool (4) creates a bidirectional open ow
path from 3 to 4 and 2 to 1.
DNB*-XE* (E Spool)
Function: When de-energized, the spool (4) creates a
bidirectional open ow path from 3 to 4 and 2 to 1. When
energized, the spool (4) creates a blocked ow path in all
directions.
DNB*-XV* (V Spool)
Function: When de-energized, the spool (4) creates a
bidirectional open ow path from 3 to 4 and 2 to 1. When
energized, the spool (4) creates a bidirectional open ow
path from 3 to 1 and blocks 2 and 4.
DNB*-XD* (D Spool)
Function: When de-energized, the spool (4) creates a
blocked ow path in all directions. When energized, the
spool (4) creates a bidirectional open ow path from 3 to
4 and 2 to 1.
DNB*-XT* (T Spool)
Function: When de-energized, the spool (4) creates a
bidirectional open ow path from 3 to 1 and blocks 2 and
4. When energized, the spool (4) creates a bidirectional
open ow path from 3 to 2 and 4 to 1.
PORT
1
PORT
2
PORT
3
PORT
4
1 2
3 4
PORT
1
PORT
2
PORT
3
PORT
4
PORT
1
PORT
2
PORT
3
PORT
4
PORT
1
PORT
2
PORT
3
PORT
4
PORT
1
PORT
2
PORT
3
PORT
4
PORT
1
PORT
2
PORT
3
PORT
4
www.sunhydraulics.com ©2019 Sun Hydraulics 3
FLeX Series
CONFIGURATIONS
747
Low- or high-power coils
DIN or Deutsch connector
12, 14, 24, or 28 Vdc
115, 230 Vac
With or without TVS diode
740
X
* *
74*
Hazardous location coils
Explosion-proof
CSA, ATEX, IECEx certied
12, 24 Vdc
115, 230 Vac
See individual coil data sheets for
full coil conguration.
Important Note:
When performing model code searches on www.sunhydraulics.com, do not
include setting(s). When ordering, no spaces or dashes are used.
COMPATIBLE COILS
BASE MODEL CODE CONFIGURATIONS
VALVE
D N B *
COIL
COIL TYPE
Directional
Spool type
4-way
Series 0
N = Buna-N
V = Viton
= Through, shift-to-cross
= Closed, shift to through
= Closed, shift to cross
= Cross, shift to closed
= Tandem, shift to through
= Cross, shift to tandem
X = no manual override
* * * *
CONFIGURATIONS
*
The DNBD 3000-psi (210-bar) valves use the low-power (17-W) coils; the DNBF 5000-psi (350 bar) valves use the high-power (25-
W) coils. Note that all DNB* valves can be used with the hazardous location coils.
Sun cartridges have a base seven-digit part number. Each
of the digits in the sequence has signicance as shown in
the model code explanation below. Available options and
modiers for specic cartridges, manifolds, and valve packages
are shown on the individual product pages and data sheets.
Not all modiers are applicable for every model.
MODEL CODE EXPLANATION
Voltage
M20 x 1.5
180°
M20 x 1.5
90°
1/2” NPT
180°
1/2” NPT 90°
Wattage
@ 20°C
Circuitry
12 Vdc 747-JM12BD 747-JM12CD 747-JN12BD 747-JN12CD 29.6 W With diode
24 Vdc 747-JM24BD 747-JM24CD 747-JN24BD 747-JN24CD 29.9 W With diode
115 Vac 747-JM11BD 747-JM11CD 747-JN11BD 747-JN11CD 29.7 W Rectied
230 Vac 747-JM23BD 747-JM23CD 747-JN23BD 747-JN23CD 28.9 W Rectied
Hazardous Location, Explosion-Proof (30-W) Coils
D
F
= 3000 psi (210 bar)
= 5000 psi (350 bar)
Voltage
DIN 43650 Form A
(IP65/IP67)
Deutsch DT04-2P
(IP69K)
Resistance @20°C (ohms) ±10%
(with diode**)
TVS Diode (Nominal)
Breakdown Voltage
(with diode*)
High-Power Low-Power High-Power Low-Power High-Power Low-Power
12 Vdc 740-212 740-212L 740-912 740-912L 5.8  8.5  68 Vdc
14 Vdc 740-214 740-214L 740-914 740-914L 7.8  11.5  68 Vdc
24 Vdc 740-224 740-224L 740-924 740-924L 23.0  33.9  68 Vdc
28 Vdc 740-228 740-228L 740-928 740-928L 31.4  46.1  68 Vdc
115 Vac 740-211 740-211L N/A N/A 416  612  250 Vac
230 Vac 740-223 740-223L N/A N/A 1686  2479  400 Vac
** Above model codes are shown without transient voltage suppression (TVS) diodes. To order 740 Series coils with a TVS
diode, append model code with “D” (Example: 740-212LD).
N
C
D
E
T
V
High-Power (25-W) & Low-Power (17-W) Coils
©2019 Sun Hydraulics4 www.sunhydraulics.com
FLeX Series
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS DNBD DNBF
Maximum Operating Pressure
3000 psi
(210 bar)
5000 psi
(350 bar)
Typical Internal Leakage at 110 SUS (24 cSt)
(at maximum operating pressure)
N spool inlet on 3: 5 in(80 cc)/min
All other spools: 2 in(30 cc)/min
N spool inlet on 3: 7 in(110 cc)/min
All other spools: 4 in(65 cc)/min
Nominal Flow Rate / Capacity 4 gpm (15 L/min)* 4 gpm (15 L/min)*
Sun Cavity T-30A
Sun Cartridge Series Series 0
Response Time - Typical 50 ms (open & close)
Switching Frequency - Maximum 4.17 Hz (15,000 cycles/hour)
Viscosity Range 2,8 to 380 cSt or 35 to 2000 SUS
Filtration Minimum cleanliness (ISO 4406 1999, 4/6/14 m) 19/17/14
Valve Hex Size 0.75 in (19,1 mm)
Valve Installation Torque 25 - 30 lbf ft (34 - 40 N-m)
Mounting Position No restrictions
Valve Weight (excluding coil) 0.66 lb (0,30 kg)
Seal Kit - Buna N 990-030-007
Seal Kit - Viton 990-030-006
Seal and nut kit - Coil 990-740-006
DNB*
4WAY, 2POSITION SOLENOIDOPERATED
DIRECTIONAL SPOOL VALVE
SERIES 0, CAVITY: T-30A
*See performance curves starting on page 5 for more details.
www.sunhydraulics.com ©2019 Sun Hydraulics 5
FLeX Series
PERFORMANCE CURVES
TYPICAL PRESSURE DIFFERENTIAL VS. FLOW
©2019 Sun Hydraulics6 www.sunhydraulics.com
FLeX Series
ADDITIONAL INFORMATIONPERFORMANCE CURVES
PERFORMANCE LIMITS @15% UNDERVOLTAGE & STABILIZED COIL TEMPERATURE
DNBD-XC*
with Low-Power Coil
DNBD-XD*
with Low-Power Coil
DNBD-XE*
with Low-Power Coil
DNBD-XN*
with Low-Power Coil
DNBD-XT*
with Low-Power Coil
DNBD-XV*
with Low-Power Coil
Note: Performance limits are derived with 4-way operation and symmetrical ow. For valve applications where either
assymmetrical ow or 3-way operation is present, these performance limits may be reduced.
www.sunhydraulics.com ©2019 Sun Hydraulics 7
FLeX Series
PERFORMANCE CURVES
PERFORMANCE LIMITS @15% UNDERVOLTAGE & STABILIZED COIL TEMPERATURE
DNBF-XC*
with High-Power Coil
DNBF-XD*
with High-Power Coil
DNBF-XE*
with High-Power Coil
DNBF-XN*
with High-Power Coil
DNBF-XT*
with High-Power Coil
DNBF-XV*
with High-Power Coil
Note: Performance limits are derived with 4-way operation and symmetrical ow. For valve applications where either
assymmetrical ow or 3-way operation is present, these performance limits may be reduced.
©2019 Sun Hydraulics8 www.sunhydraulics.com
FLeX Series
747 SERIES HAZARDOUS LOCATION COILS
DNB* FAMILY WITH 740 SERIES HIGH-POWER & LOW-POWER COILS
1.50 [38,0] HIGH POWER
1.22 [31,0] LOW POWER
1.32 [33,5]
1.60 [40,6]
X CONTROL 3.22 [81,7]
DIMENSIONAL DRAWINGS
90° CONNECTOR 180° CONNECTOR
NOTE: Please verify cartridge clearance requirements when choosing a Sun manifold. Dierent valve controls and coils require dierent
clearances. An additional minimum 2.0 in. (50,8 mm) beyond the valve extension is needed for coil installation and removal.
1.62 [41,1] .88 [22,4]
3.55 [90,2]
2.69 [68,3]
www.sunhydraulics.com ©2019 Sun Hydraulics 9
FLeX Series
NOTE: For cavity tooling, see table below.
For full cavity detail, download the latest
drawings from our website.
https://www.sunhydraulics.com/cavity/T-30A
T-30A CAVITY DIMENSIONAL DRAWING & TOOLING
DESCRIPTION HIGH-SPEED STEEL TITANIUM COATED
M20 X 1.5-6H tap, straight shank 998991 998991101
Series 1 deep hex socket 998100005
T-30A cavity form drill, morse taper 994030001 994030101
T-30A cavity form drill, straight shank 994030002 994030102
T-30A cavity form reamer, morse taper 995030001 995030101
T-30A cavity form reamer, straight shank 995030002 995030102
CAVITY DRAWING & TOOLING
T30A CAVITY
LOCATING SHOULDER
M16X1,5-6H
PORT
PORT
PORT
PORT
1
2
3
4
.745 (18,92)
.743 (18,87)
.313 MAX
(7,92)
.543
(13,79)
1.165
(29,59)
.313 MAX
(7,92)
.313 MAX
(7,92)
CARTRIDGE NOSE SUPPORT
.313
MAX
(7,92)
.531 MIN
FULL THD
(13,49)
2.243 (56,97)
2.240 (56,90)
1.771
(44,98)
©2019 Sun Hydraulics10 www.sunhydraulics.com
FLeX Series
www.sunhydraulics.com ©2019 Sun Hydraulics 11
FLeX Series
Sun Hydraulics Headquarters
Sarasota, Florida USA
+1 941 362 1200
Sun Hydraulics Korea Corp.
Incheon, Korea
+82 3281 31350
sales@sunhydraulics.co.kr
Sun Hydraulics Limited
Coventry, England
+44 2476 217 400
sales@sunuk.com
Sun Hydraulics China Co. Ltd.
Shanghai, P.R. China
+86 2162 375885
sunchinainfo@sunhydraulics.com
Sun Hydraulik GmbH
Erkelenz, Germany
+49 2431 80910
sales@sunhydraulik.de
Sun Hydraulics Corp. (India)
Bangalore, India
+91 8028 456325
sunindiainfo@sunhydraulics.com
Sun Hydraulics Corp. (S.America)
Rosario, Argentina
+54 9 341 584 3075
ventas@sunhydraulics.com
Custom Fluidpower Pty Ltd
(A Sun Hydraulics Company)
Newcastle, Australia
+61 2 4953 5777
sales@custom.com.au
August 2019
©2019 Sun Hydraulics12 www.sunhydraulics.com
FLeX Series
T-30A CAVITY DIMENSIONAL DRAWING
ACCESSORIES
STANDARD LINE-MOUNT MANIFOLDS
DESCRIPTION PART NUMBER
Wire harness, 2-pin Deutsch-to-Metri-Pack Conversion 991-717
Wire harness, 2-pin Deutsch-to-Amp Jr Timer Conversion 991-718
Wire harness, 2-pin Deutsch-to-Twin-Lead Conversion 991-719
The DNB* family of FLeX valves is based on the new Sun T-30A cavity. Currently, there are six standard
single-cavity, 90-degree line mount manifolds available in a wide range of port sizes for the new T-30A
cavity. More standard manifolds will be introduced soon, including two-cavity and sandwich style
manifolds for this new cavity.
Visit our website to see a complete list of available standard manifolds for the T-30A cavity.
ADDITIONAL INFORMATION
1
2
3
4