www.suco.de
59
Technical data
Type
0605 0610 0620
Output signal:
0.5 – 4.5 V
radiometrically
0 – 10 V
(3-wire)
4 – 20 mA
(2-wire)
Supply voltage U
b
: 5 VDC ± 10 % 12 – 32 VDC 12 – 32 VDC
Maximum load: ≥ 4.7 kΩ ≥ 4.7 kΩ ≤ (U
b
– 12 V) / 20 mA
Current consumption
(without load):
≤ 10 mA ≤ 15 mA –
Pressure ranges
p
range
:
-1 – 0 bar; 0 – 10 bar; 0 – 16 bar; 0 – 100 bar;
0 – 250 bar; 0 – 400 bar; 0 – 600 bar; 0 – 1000 bar
Accuracy: ±0.5 % full scale at room temperature
Response time
(10 – 90 %):
max. 2 ms
Temperature range: -40 °C – +125 °C -40 °C – +105 °C -40 °C – +100 °C
Temperature drift: approx. ±0.2 % / 10 K
Mechanical life
expectancy:
10
7
pulses up to nominal p
range
Overpressure
safety
1)
:
2 x p
range
up to 350 bar; 1.5 x p
range
up to 600 bar; 1.2 x p
range
at 1000 bar
Bursting pressure
1)
: 3 x p
range
up to 350 bar; 2 x p
range
up to 600 bar; 1.5 x p
range
at 1000 bar
Materials:
Body material:
Diaphragm: < 500 bar:
Diaphragm: > 500 bar:
1.4301 / AISI 304
1.4301 / AISI 304
1.4542 / AISI 630
Reverse polarity
protection:
built-in
Protection according
to DIN EN 60 529:
IP67 for M12x1, DIN 72585, AMP Superseal and Deutsch DT04-4P
IP65 for DIN EN 175301-803, AMP JT and cable connection
Weight:
approx. 120 g
(DIN EN 175301 approx. 130 g)
Vibration resistance: 20 g at 4 – 2000 Hz sine
Max. length of
connection cable:
30 m / 100 ft
EMC Standards: DIN EN 61000-6-2, DIN EN 61000-6-3
CE marking
SUCO pressure transmitters are
covered by the EMV-directive
89/336/EC.
An EC Declaration of
Conformity has been issued
for these pressure transmitters
and is on file at our offices.
The corresponding switches
bear the CE mark in our
catalogue.
Degree of protection IP65
The type approval does not
apply without restriction to all
environmental conditions. It is
the responsibility of the user to
check whether the electrical
connection complies with
regulations other than those
stated and whether it can be
used for special applications
which could not be foreseen
by us.
Oxygen warning!
When using oxygen, the
relevant safety regulations
must be observed. In addition,
we recommend that a
maximum operating pressure
of 10 bar must not be exceeded.
1)
Static pressure, dynamic pressures should be 30 to 50% lower. These values refer to the hydraulic or pneu-
matic part of the pressure switch.