www.suco.de
55
0520 0570
Switching fuction: Normally open / normally closed
Normally open / normally closed, pro-
grammable, 2 switching points, time-
delayed switching, zero-resetting,
peak-value memory (within setting
range), switching-point counter
Hysteresis:
2 – 95 % programmable
at our works
(max. tolerance ± 1.0 % full scale)
1 – 99 % programmable
using key-pad
Adjustment:
Switching point can be set on site
by the customer using an screw-
driver via setting potentiometer
when operating voltage is applied
Programmable using key-pad
on front face
Outputs:
Transistor output
(1.4 A DC12 / PNP)
2 transistor outputs
(each 1.4 A DC12 / PNP)
1 analogue output (4 – 20 mA)
Indication of
output status:
– By 2 LEDs (yellow)
Time-delayed
switching:
– Adjustable 0 – 3.0 s
Pressure display: –
Current pressure can be shown in
bar or PSI on 3-digit LED-display (red)
Materials: zinc-plated steel body (CrVI-free)
Medium-contact parts anodised alu-
minium, body made of die-casted zinc
Access coding: –
The switch can have a number code
between 1 and 999
Supply voltage: 18 – 36 VDC 12 – 30 VDC
Degree of protection: IP65
Switching time: < 4 ms
Accuracy: ± 0.5 % (full scale at room temperature)
Temperature range:
NBR, EPDM: - 20 °C – +80 °C
FKM: - 5 °C – + 80 °C
Temperature
compensation:
- 20 °C – + 80 °C, error ≤ ± 1.5 % overall
Temperature drift: ± 0.2 % / 10 K
Life expectancy: 5 x 10
6
cycles
Pressure rise rate: ≤ 1 bar / ms
Vibration resistance: 10 g at 5 – 2000 Hz sine-wave
Shock resistance: 294 m / s
2
, 14 ms half-sine-wave to DIN 40046
EMV: acc. to EN 50081-1, EN 50081-2, EN 50082-2
Weight in grams: approx. 240 g approx. 340 g
Degree of protection IP65
The type approval does not
apply without restriction to all
environmental conditions. It is
the responsibility of the user to
check whether the electrical
connection complies with
regulations other than those
stated and whether it can be
used for special applications
which could not be foreseen by
us.
Oxygen warning!
When using oxygen, the
relevant safety regulations
must be observed. In addition,
we recommend that a
maximum operating pressure
of 10 bar must not be exceeded.
Technical data