www.suco.de
4444
Aluminium body
With changeover switch and silver contacts
Overpressure safe to 200 / 600 bar
1)
With socket device similar to DIN EN 175301 (DIN 43650)
Adjustable hysteresis at works
0161/ 0162
Diaphragm / piston pressure switches 250 V
39
ø 5.5
G
1
/
4
20
30
Pg 9
1
To adjust the set point, loose the locknut and turn
the set screw with a screwdriver. Clock-wise screwing
increases the switching pressure. After adjusting, tighten
the locknut again.
0161 With female thread
0162 Manifold mounting
p
max.
in bar
Adjustment range
in bar
(tolerance at room
temperature)
dim. A
in mm
Female thread G 1/4 Manifold mounting
Diaphragm pressure switches 0161 0162
2)
200
1)
0.5 – 1 (± 0.2)
15
0161 436 14 X 001 0162 436 14 X 001
0.5 – 5 (± 0.2 – 0.5) 0161 437 14 X 001 0162 437 14 X 001
1 – 10 (± 0.5) 0161 438 14 X 001 0162 438 14 X 001
10 – 50 (± 3.0) 0161 439 14 X 001 0162 439 14 X 001
50 – 100 (± 3.0 – 5.0) 0161 440 14 X 001 0162 440 14 X 001
Piston pressure switches 0161 0162
2)
600
1)
100 – 400 (± 5.0 – 9.0) 19.5 0161 441 14 X 001 0162 441 14 X 001
Diaphragm / seal material
– areas of application
NBR Hydraulic / machine oil, heating oil, air, nitrogen etc.
1
EPDM Brake uid, ozone, acetylene, hydrogen etc.
2
FKM Hydraulic uids (HFA, HFB, HFD), petrol/gasoline etc.
3
See page 42 for temperature ranges of diaphragm materials
Order number:
016X XXX 14 X 001
2)
0162:
Scope of supply includes O-ring NBR 5x1.5mm
1
Our pressure switches are
also available with factory
pre-set switching points.
For further technical data
and electrical values see
page 42.
Degree of protection IP65
The type approval does not apply without restriction to all environmental conditions. It is the responsi-
bility of the user to check whether the electrical connection complies with regulations other than those
stated, and whether it can be used for special applications which could not be foreseen by us.
Warning !
When using oxygen, the relevant accident prevention regulations must be observed. In addition,
we recommend that a maximum operating pressure of 10 bar is not exceeded.
Piston pressure switches are only to a limited extent suitable for use with gases.
See explanation on page 9.
1)
Static pressure, dynamic pressures should be 30 to 50% lower. These values refer to the hydraulic or pneu-
matic part of the pressure switch.
83