72 SCHROEDER INDUSTRIES
Top-Ported Pressure Filter
PF40
Filter
Model
Number
Selection
NOTES:
Box 2. Replacement element
part numbers are a
combination of Boxes
2, 3 and 4.
Example: 5HZ10V
Box 4. For options H, V, and
H.5, all aluminum parts
are anodized. H.5 seal
designation includes
the following: EPR seals,
stainless steel wire mesh
on elements, and light
oil coating on housing
exterior. Viton
®
is a
registered trademark of
DuPont Dow Elastomers.
Skydrol
®
is a registered
trade mark of Solutia Inc.
Box 5. B porting option
supplied with metric
mounting holes.
BOX 1 BOX 2 BOX 3
Filter
Series
Element
Length (in)
Element Part Number
PF40
5
HZ1 = H size 1 µ Excellement
®
Z-Media
®
(synthetic)
PFN40
(Non-
bypassing:
requires ZX
high collapse
elements)
9
HZ3 = H size 3 µ Excellement
®
Z-Media
®
(synthetic)
HZ5 = H size 5 µ Excellement
®
Z-Media
®
(synthetic)
HZ10 = H size 10 µ Excellement
®
Z-Media
®
(synthetic)
HZ25 = H size 25 µ Excellement
®
Z-Media
®
(synthetic)
HZX3 = H size 3 µ Excellement
®
Z-Media
®
(high collapse center tube)
HZX10 = H size 10 µ Excellement
®
Z-Media
®
(high collapse center tube)
HZX25 = H size 25 µ Excellement
®
Z-Media
®
(high collapse center tube)
BOX 4 BOX 5 BOX 6
Seal Material Porting Options
Omit = Buna N
O
= Manifold
Mounting
(Contact
factory)
Omit = None
H = EPR
L
= Two
1
⁄
4
" NPTF inlet & outlet female
test ports
V = Viton
®
S = SAE-16
U = Schroeder Check
7
⁄
16
"-20 UNF test point
installation in head (upstream)
H.5 = Skydrol
®
compatibility B = ISO 228 G-1"
BOX 7
Dirt Alarm
®
Options
Omit = None
Visual D5 = Visual pop-up
Visual with
Thermal
Lockout
D8 = Visual w/ thermal lockout
Electrical
MS5 = Electrical w/ 12 in. 18 gauge 4-conductor cable
MS5LC = Low current MS5
MS10 = Electrical w/ DIN connector (male end only)
MS10LC = Low current MS10
MS11 = Electrical w/ 12 ft. 4-conductor wire
MS12 =
Electrical w/ 5 pin Brad Harrison connector (male end only)
MS12LC = Low current MS12
MS16 = Electrical w/ weather-packed sealed connector
MS16LC = Low current MS16
MS17LC = Electrical w/ 4 pin Brad Harrison male connector
Electrical
with
Thermal
Lockout
MS5T = MS5 (see above) w/ thermal lockout
MS5LCT = Low current MS5T
MS10T = MS10 (see above) w/ thermal lockout
MS10LCT = Low current MS10T
MS12T = MS12 (see above) w/ thermal lockout
MS12LCT = Low current MS12T
MS16T = MS16 (see above) w/ thermal lockout
MS16LCT = Low current MS16T
MS17LCT = Low current MS17T
Electrical
Visual
MS13 = Supplied w/ threaded connector & light
MS14 =
Supplied w/ 5 pin Brad Harrison connector & light (male end)
Electrical
Visual with
Thermal
Lockout
MS13DCT = MS13 (see above), direct current, w/ thermal lockout
MS13DCLCT = Low current MS13DCT
MS14DCT = MS14 (see above), direct current, w/ thermal lockout
MS14DCLCT = Low current MS14DCT
BOX 8
Dirt Alarm
®
Location
Omit = Top mounted
S = Side mounted
BOX 9
Bowl Drain Options
Omit = None
DR = Drain
7
⁄
16
"-20
How to Build a Valid Model Number for a Schroeder PF40:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9
PF40 – – – – – – – –
Example:
NOTE: Only box 6 may contain more than one option
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9
PF40 – 5 – HZ3 – – S – – D5 – S –
= PF405HZ3SD5S