108 SCHROEDER INDUSTRIES
Base-Ported Pressure Fil ter
KF50
Filter
Model
Number
Selection
NOTES:
Box 2. Number of elements
must equal 1
when using KK
or 27K elements.
Replacement element
part numbers are
identical to contents
of Boxes 2, 3, 4 and 5.
Double and triple
stacking of K-size
elements can be
replaced by single
KK and 27K elements,
respectively. ZW media
not available in 27K
length.
Box 5. H.5 seal designation
includes the
following: EPR seals,
stainless steel wire mesh
on elements, and light
oil coating on housing
exterior. Viton
®
is a
registered trademark of
DuPont Dow Elastomers.
Skydrol
®
is a registered
trade mark of Solutia Inc.
Box 7. For option F, bolt depth
.75" (19 mm). For option
O, O-rings included;
hardware not included.
Box 9. Standard indicator
setting for non-
bypassing model is
50 psi unless otherwise
specified.
Box 10. Options N, G509 and
G588 are not available
with KFN50. N option
should be used in
conjunction with
dirt alarm.
How to Build a Valid Model Number for a Schroeder KF50:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
KF50 – – – – – – – – –
Example:
NOTE: Only boxes 8 and 10 may contain more than one option
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
KF50 – 1K – Z – 10 – – – S – – D5 – = KF501KZ10SD5
BOX 1 BOX 2 BOX 3
Filter
Series
Number & Size of
Elements
Media Type
KF50
1
K, KK, 27K
Omit E Media (Cellulose)
2
K
Z Excellement
®
Z-Media
®
(synthetic)
KFN50
(Non-
bypassing:
requires ZX
high collapse
elements)
3
K
AS Anti-Stat Media (synthetic)
ZW Aqua-Excellement
™
ZW Media
ZX
Excellement
®
Z-Media
®
(High Collapse centertube)
W W Media (water removal)
M Media (reusable metal mesh)
BOX 7
Porting
P = 1
1
⁄2" NPTF
P32 = 2" NPTF
S = SAE-24
F = 1
1
⁄2" SAE
4-bolt
flange
Code 62
O = Subplate
B24 =
I
SO 228
G-1
1
⁄2"
BOX 8
Options
Omit = None
X = Blocked bypass
50 = 50 psi bypass setting
L = Two
1
⁄4" NPTF inlet and outlet female test ports
U = Series 1215
7
⁄16 UNF Schroeder Check Test Point
installed in cap (upstream)
UU = Series 1215
7
⁄16 UNF Schroeder Check Test Point
installed in block (upstream and downstream)
BOX 10
Additional Options
Omit = None
N = No-Element Indicator
(not available w/
KFN50 or housings
w/ indicator in cap
G509 = Dirt alarm and drain
opposite standard
G588 = Electrical switch
and drain opposite
standard
BOX 4
MIcron Rating
1 = 1 Micron (Z, ZW, ZX media)
3 = 3 Micron
(AS,E, Z, ZW, ZX media)
5 = 5 Micron
(AS, Z, ZW, ZX media)
10 = 10 Micron
(AS,E,M, Z, ZW, ZX media)
25 = 25 Micron
(E,M, Z, ZW, ZX media)
60 = 60 Micron
(M media)
150 = 150 Micron
(M media)
260
= 260 Micron
(M media)
BOX 5
Seal Material
Omit = Buna N
V = Viton
®
H = EPR
H.5
= Skydrol
®
compatibility
BOX 6
Magnet Options
Omit = None
M
= Magnet
inserts (not
available w/
indicator in
cap)
BOX 9
Dirt Alarm
®
Options
Omit = None
Visual
D = Pointer
D5 = Visual pop-up
D5C = D5 in cap
D9 = All stainless D5
Visual with
Thermal
Lockout
D8 = Visual w/ thermal lockout
D8C = D8 in cap
Electrical
MS5 = Electrical w/ 12 in. 18 gauge 4-conductor cable
MS5LC = Low current MS5
MS10 = Electrical w/ DIN connector (male end only)
MS10LC = Low current MS10
MS11 = Electrical w/ 12 ft. 4-conductor wire
MS12 =
Electrical w/ 5 pin Brad Harrison connector (male end only)
MS12LC = Low current MS12
MS16 = Electrical w/ weather-packed sealed connector
MS16LC = Low current MS16
MS17LC = Electrical w/ 4 pin Brad Harrison male connector
Electrical
with
Thermal
Lockout
MS5T = MS5 (see above) w/ thermal lockout
MS5LCT = Low current MS5T
MS10T = MS10 (see above) w/ thermal lockout
MS10LCT = Low current MS10T
MS12T = MS12 (see above) w/ thermal lockout
MS12LCT = Low current MS12T
MS16T = MS16 (see above) w/ thermal lockout
MS16LCT = Low current MS16T
MS17LCT = Low current MS17T
Electrical
Visual
MS = Cam operated switch w/ ½" conduit female connection
MS13 = Supplied w/ threaded connector & light
MS14 =
Supplied w/ 5 pin Brad Harrison connector & light (male end)
Electrical
Visual with
Thermal
Lockout
MS13DCT = MS13 (see above), direct current, w/ thermal lockout
MS13DCLCT = Low current MS13DCT
MS14DCT = MS14 (see above), direct current, w/ thermal lockout
MS14DCLCT = Low current MS14DCT