SCHROEDER INDUSTRIES 105
NF30
NFS30
YF30
CFX30
PLD
DF40
CF40
PF40
RFS50
RF60
CF60
CTF60
VF60
LW60
KF30
TF50
KF50
KC50
MKF50
KC65
NOF30-05
NOF50-760
FOF60-03
NMF30
RMF60
Cartridge
Elements
HS60
MHS60
KFH50
Flow Rating:
Up to 100 gpm (380 L/min) for 150 SUS (32 cSt) fluids
With 2" porting only, up to 150 gpm (570 L/min) for 150 SUS (32 cSt) fluids
Max. Operating Pressure:
5000 psi (345 bar)
Min. Yield Pressure:
15,000 psi (1035 bar), per NFPA T2.6.1
Rated Fatigue Pressure:
3500 psi (240 bar), per NFPA T2.6.1-2005
Temp. Range:
-20°F to 225°F (-29°C to 107°C)
Bypass Setting:
Cracking: 40 psi (2.8 bar) Optional Cracking: 50 psi (3.5 bar)
Full Flow: 61 psi (4.2 bar)
Non-bypassing model has a blocked bypass.
Porting Base & Cap:
Element Case:
Ductile Iron
Steel
Weight of KF50-1K:
Weight of KF50-2K:
Weight of KF50-3K:
59.7 lbs. (27.1 kg)
80.7 lbs. (36.6 kg)
102.0 lbs. (46.3 kg)
Element Change Clearance:
8.50" (215 mm) for 1K; 17.50" (445 mm) for KK; 26.5" (673 mm) for 27K
Base-Ported Pres sure Filter
KF50
100/150 gpm
380/570 L/min
5000 psi
345 bar
Filter
Housing
Specifications
Applications
Features and Benefits
Base-ported high pressure filter
Can be installed in vertical or horizontal
position
Meets HF4 automotive standard
Element changeout from top minimizes
oil spillage
Offered in pipe, SAE straight thread,
flanged and ISO 228 porting
No-Element indicator option available
Available with non-bypass option
with high collapse element
Integral inlet and outlet female test
points option available
Offered in conventional subplate
porting
Double and triple stacking of K-size
elements can be replaced by single
KK or 27K-size elements
Model No. of filter in photograph is KF501K10SD.
106 SCHROEDER INDUSTRIES
Base-Ported Pressure Fil ter
KF50
Element
Performance
Information
Element
DHC
(gm) Element
DHC
(gm) Element
DHC
(gm) Element
DHC
(gm) Element
DHC
(gm)
K3
54
KK3 108 27K3 162
K10
44
KK10 88 27K10 132
KZ1
112
KKZ1 224 27KZ1 336 KZW1 61
KZ3/KAS3
115
KKZ3/KKAS3 230 27KZ3/27KAS3 345 KZW3 64 KKZW3
128
KZ5/KAS5
119
KKZ5/KKAS5 238 27KZ5/27KAS5 357 KZW5 63 KKZW5
126
KZ10/KAS10
108
KKZ10 216 27KZ10/27KAS10 324 KZW10 57 KKZW10
114
KZ25
93
KKZ25 186 27KZ25 279 KZW25 79 KKZW25
158
KZX3
40*
KKZX3 80 27KZX3 120
KZX10
49*
KKZX10 98 27KZX10 147
Element Collapse Rating: 150 psid (10 bar) for standard elements
3000 psid (210 bar) for high collapse (ZX) versions
Flow Direction:
Outside In
Element Nominal Dimensions:
K: 3.9" (99 mm) O.D. x 9.0" (230 mm) long
KK: 3.9" (99 mm) O.D. x 18.0" (460 mm) long
27K: 3.9" (99 mm) O.D. x 27.0" (690 mm) long
* Based on 100 psi
terminal pressure
Dirt Holding
Capacity
Filtration Ratio Per
ISO 4572/NFPA T3.10.8.8
Using automated particle counter (APC)
calibrated per ISO 4402
Filtration Ratio wrt ISO 16889
Using APC calibrated per ISO 11171
Element ß
x
≥ 75 ß
x
≥ 100 ß
x
≥ 200 ß
x
(c)
≥ 200 ß
x
(c)
≥ 1000
K3/KK3/27K
6.8 7.5 10.0 N/A N/A
K10/KK10/27K10
15.5 16.2 18.0 N/A N/A
KZ1/KKZ1/27KZ1
<1.0 <1.0 <1.0 <4.0 4.2
KZ3/KKZ3/27KZ3/KAS3/KKAS3/27KAS3
<1.0 <1.0 <2.0 <4.0 4.8
KZ5/KKZ5/27KZ5/KAS5/KKAS5/27KAS5
2.5 3.0 4.0 4.8 6.3
KZ10/KKZ10/27KZ10/KAS10/KKAS10/27KAS10
7.4 8.2 10.0 8.0 10.0
KZ25/KKZ25/27KZ25
18.0 20.0 22.5 19.0 24.0
KZW1
N/A N/A N/A <4.0 <4.0
KZW3/KKZW3
N/A N/A N/A 4.0 4.8
KZW5/KKZW5
N/A N/A N/A 5.1 6.4
KZW10/KKZW10
N/A N/A N/A 6.9 8.6
KZW25/KKZW25
N/A N/A N/A 15.4 18.5
KZX3/KKZX3/27KZX3
<1.0
<1.0 <2.0 4.7 5.8
KZX10/KKZX10/27KZX10
7.4
8.2 10.0 8.0 9.8
Metric di men sions in ( ).
SCHROEDER INDUSTRIES 107
NF30
NFS30
YF30
CFX30
PLD
DF40
CF40
PF40
RFS50
RF60
CF60
CTF60
VF60
LW60
KF30
TF50
KF50
KC50
MKF50
KC65
NOF30-05
NOF50-760
FOF60-03
NMF30
RMF60
Cartridge
Elements
HS60
MHS60
KFH50
Type Fluid Appropriate Schroeder Media
Petroleum Based Fluids
All E media (cellulose), Z-Media
®
and ASP Media (synthetic)
High Water Content
All Z-Media
®
and ASP Media (synthetic)
Invert Emulsions
10 and 25 µ Z-Media
®
(synthetic), 10 µ ASP Media
Water Glycols
3, 5, 10 and 25 µ Z-Media
®
(synthetic) and all ASP Media (synthetic)
Phosphate Esters
All Z-Media
®
and ASP Media (synthetic) with H (EPR) seal designation and 3
and 10 µ E media (cellulose) with H (EPR) seal designation
Skydrol
®
3, 5, 10 and 25 µ Z-Media
®
(synthetic) and all ASP Media (synthetic) with H.5 seal
designation and W media (water removal) with H.5 seal designation (EPR seals and
stainless steel wire mesh in element, and light oil coating on housing exterior)
sp gr = specific gravity
Sizing of elements should be based on element flow
information provided in the Element Selection chart above.
∆P
element
∆P
element
= flow x element ∆P factor x viscosity factor
El. ∆P factors @ 150 SUS (32 cSt):
1K 2K/KK 3K/27K
K3 .25 .12 .08
K10 .09 .05 .03
K25 .02 .01 .01
KZ1 .20 .10 .05
KZ3/KAS3/KKAS3/27KAS3 .10 .05 .03
KZ5/KAS5/KKAS5/27KAS5 .08 .04 .02
KZ10/KAS10/
KKAS10/27KAS10
.05 .03 .02
KZ25 .04 .02 .01
KZX10 .08 .04 .03
1K 2K
KZW1 .43
KZW3 .32 .16
KZW5 .28 .14
KZW10 .23 .12
KZW25 .14 .07
If working in units of bars & L/min, divide above factor
by 54.9.
Viscosity factor: Divide viscosity by 150 SUS (32 cSt).
∆P
housing
KF50 ∆P
housing
for fluids with sp gr = 0.86:
Pressure
Element
Flow capacity selections are predicated on the use of 150 SUS
(32 cSt) petroleum based fluid and a 40 psi (2.8 bar) bypass valve.
Series Part No.
To
5000 psi
(345 bar)
E
Media
K3 1K3 2K3† 3K3 See MKF50
K10 1K10 2K10† 3K10† 3K10† See MKF50
K25 1K25 2K25†
Z-
Media
®
KZ1 1KZ1 2KZ1† 3KZ1†
KZ3 1KZ3/KAS3/KKAS3/27KAS3 2KZ3† 3KZ3†
KZ5 1KZ5/KAS5/KKAS5/27KAS5 2KZ5† 3KZ5†
KZ10 1KZ10/KAS10/KKAS10/27KAS10 2KZ10†
3KZ10†
KZ25 1KZ25 2KZ25†
Flow
gpm 25 50 75 100 125 150
(L/min) 100 200 300 400 500 570
Double and triple stacking of K-size elements can
be replaced by single KK & 27K elements, respectively.
Shown above are the elements most commonly used in this housing.
Note: Contact factory regarding use of E Media in High Water Content, Invert Emulsion and Water Glycol
Applications. For more information, refer to Fluid Compatibility: Fire Resistant Fluids, pages 19 and 20.
0
0
requires 2" porting (P32)
∆P
filter
= ∆P
housing
+ ∆P
element
Exercise:
Determine ∆P at 50 gpm (190 L/min) for
KF501KZ3PD5 using 200 SUS (44 cSt) fluid.
Solution:
∆P
housing
= 3.0 psi [.20 bar]
∆P
element
= 50 x .10 x (200÷150) = 6.7 psi
or
= [190 x (.10÷54.9) x (44÷32) = .48 bar]
∆P
total
= 3.0 + 6.7 = 9.7 psi
or
= [.20 + .48 = .68 bar]
Base-Ported Pres sure Filter
KF50
Flow Capacity
Selection
Based on
Pressure Drops
Fluid
Compatibility
Pressure
Drop
Information
Based on
Flow Rate
and Viscosity
Skydrol
®
is a registered
trademark of Solutia Inc.
108 SCHROEDER INDUSTRIES
Base-Ported Pressure Fil ter
KF50
Filter
Model
Number
Selection
NOTES:
Box 2. Number of elements
must equal 1
when using KK
or 27K elements.
Replacement element
part numbers are
identical to contents
of Boxes 2, 3, 4 and 5.
Double and triple
stacking of K-size
elements can be
replaced by single
KK and 27K elements,
respectively. ZW media
not available in 27K
length.
Box 5. H.5 seal designation
includes the
following: EPR seals,
stainless steel wire mesh
on elements, and light
oil coating on housing
exterior. Viton
®
is a
registered trademark of
DuPont Dow Elastomers.
Skydrol
®
is a registered
trade mark of Solutia Inc.
Box 7. For option F, bolt depth
.75" (19 mm). For option
O, O-rings included;
hardware not included.
Box 9. Standard indicator
setting for non-
bypassing model is
50 psi unless otherwise
specified.
Box 10. Options N, G509 and
G588 are not available
with KFN50. N option
should be used in
conjunction with
dirt alarm.
How to Build a Valid Model Number for a Schroeder KF50:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
KF50 –
Example:
NOTE: Only boxes 8 and 10 may contain more than one option
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
KF50 – 1K Z 10 S D5 = KF501KZ10SD5
BOX 1 BOX 2 BOX 3
Filter
Series
Number & Size of
Elements
Media Type
KF50
1
K, KK, 27K
Omit E Media (Cellulose)
2
K
Z Excellement
®
Z-Media
®
(synthetic)
KFN50
(Non-
bypassing:
requires ZX
high collapse
elements)
3
K
AS Anti-Stat Media (synthetic)
ZW Aqua-Excellement
ZW Media
ZX
Excellement
®
Z-Media
®
(High Collapse centertube)
W W Media (water removal)
M Media (reusable metal mesh)
BOX 7
Porting
P = 1
1
2" NPTF
P32 = 2" NPTF
S = SAE-24
F = 1
1
2" SAE
4-bolt
flange
Code 62
O = Subplate
B24 =
I
SO 228
G-1
1
2"
BOX 8
Options
Omit = None
X = Blocked bypass
50 = 50 psi bypass setting
L = Two
1
4" NPTF inlet and outlet female test ports
U = Series 1215
7
16 UNF Schroeder Check Test Point
installed in cap (upstream)
UU = Series 1215
7
16 UNF Schroeder Check Test Point
installed in block (upstream and downstream)
BOX 10
Additional Options
Omit = None
N = No-Element Indicator
(not available w/
KFN50 or housings
w/ indicator in cap
G509 = Dirt alarm and drain
opposite standard
G588 = Electrical switch
and drain opposite
standard
BOX 4
MIcron Rating
1 = 1 Micron (Z, ZW, ZX media)
3 = 3 Micron
(AS,E, Z, ZW, ZX media)
5 = 5 Micron
(AS, Z, ZW, ZX media)
10 = 10 Micron
(AS,E,M, Z, ZW, ZX media)
25 = 25 Micron
(E,M, Z, ZW, ZX media)
60 = 60 Micron
(M media)
150 = 150 Micron
(M media)
260
= 260 Micron
(M media)
BOX 5
Seal Material
Omit = Buna N
V = Viton
®
H = EPR
H.5
= Skydrol
®
compatibility
BOX 6
Magnet Options
Omit = None
M
= Magnet
inserts (not
available w/
indicator in
cap)
BOX 9
Dirt Alarm
®
Options
Omit = None
Visual
D = Pointer
D5 = Visual pop-up
D5C = D5 in cap
D9 = All stainless D5
Visual with
Thermal
Lockout
D8 = Visual w/ thermal lockout
D8C = D8 in cap
Electrical
MS5 = Electrical w/ 12 in. 18 gauge 4-conductor cable
MS5LC = Low current MS5
MS10 = Electrical w/ DIN connector (male end only)
MS10LC = Low current MS10
MS11 = Electrical w/ 12 ft. 4-conductor wire
MS12 =
Electrical w/ 5 pin Brad Harrison connector (male end only)
MS12LC = Low current MS12
MS16 = Electrical w/ weather-packed sealed connector
MS16LC = Low current MS16
MS17LC = Electrical w/ 4 pin Brad Harrison male connector
Electrical
with
Thermal
Lockout
MS5T = MS5 (see above) w/ thermal lockout
MS5LCT = Low current MS5T
MS10T = MS10 (see above) w/ thermal lockout
MS10LCT = Low current MS10T
MS12T = MS12 (see above) w/ thermal lockout
MS12LCT = Low current MS12T
MS16T = MS16 (see above) w/ thermal lockout
MS16LCT = Low current MS16T
MS17LCT = Low current MS17T
Electrical
Visual
MS = Cam operated switch w/ ½" conduit female connection
MS13 = Supplied w/ threaded connector & light
MS14 =
Supplied w/ 5 pin Brad Harrison connector & light (male end)
Electrical
Visual with
Thermal
Lockout
MS13DCT = MS13 (see above), direct current, w/ thermal lockout
MS13DCLCT = Low current MS13DCT
MS14DCT = MS14 (see above), direct current, w/ thermal lockout
MS14DCLCT = Low current MS14DCT