CHECK VALVE MODEL : CV
PRISM HYDRAULICS PVT. LTD.
P0405
R ef.No. P 0405
R elease Oct 20 0 0
[3 ]
Technical Specifications
Construction . . . . . . . . . . . . . . . . . . . . . . Seat type.
Mounting . . . . . . . . . . . . . . . . . . . . . . Inline or subplate mounting
Interface . . . . . . . . . . . . . . . . . . . . . . . . Factory standard
Mounting position . . . . . . . . . . . . . . . . . .Optional.
Flow direction . . . . . . . . . . . . . . . . . . . . . . Free flow from port A to B.
Leakage free closure in opposite direction
Operating pressure . . . . . . . . . . . . . . . . . . 315 bar.
Hydraulic medium . . . . . . . . . . . . . . . . . . .Mineral oil.
Viscosity range . . . . . . . . . . . . . . . . . . . . 10 cSt to 380 cSt
Fluid tem perature range . . . . . . . . . . . . . . . -20 ➊c to + 70 ➊c
Fluid cleanliness requirement . . . . . . . . . . As per ISO 16/13 or better
Nominal flow handling capacity . . . . . . . . .
Cracking pressure (bar) . . . . . . . . . . . . . . 0.5, 1.5, 3 or 5.
Ordering Code
Note :- Subplate to be ordered seperately.
For ordering code ref Table No.3
Sizes 08, 15 & 25 are available only in threaded mounting.
CV 20 G 2 01
Check valve.
Size 06,08,10,15,20,25 & 30
Inline
Subplate
G
P
Mounting
Cracking pressure(bar)
1
2
3
4 5
3
1.5
0.5
Design code sub to change.
Installation dimns remian
same for code 01 thru 09
Size O6 08 10 15 20 25 30
Flow(l/min) 10 20 30 80 120 220 280