A Polyhydron Group Company
D 04897 - PPR
ENGINEERING - 3 of 3
All rights reserved.
Subject to revision
a
A B
P
T
Threaded body -
Subplate mounting -
Pressure relief valve
Pilot operated
Set screw -
Hand knob -
Threaded bodies -
Subplate mounting -
Internal drain - Omit
External drain -
Omit if not required
- Sol. Valve normally closed.
- Sol. Valve normally opened.
Note 1 : Solenoid ( refer spool type )
Spool Type
Provision for mounting solenoid valve
Pr. adjustment spring rating
Design code subject to change.
Installation dimensions remain
same for design code 10 thru 19.
Model Design code
PPR*10S
PPR*20S
PPR*30S
PPR*20T
PPR*30T
Construction ............................................... Two stage poppet valve.
Mounting .................................................... Threaded bodies - Company standards
Subplate mounting - ISO6264.
Mounting position ...................................... Optional.
Flow direction ............................................ From port P to port T.
Maximum Operating pressure
For port P and X ............... 315 bar.
For port T and Y ............... 210 bar.
( For model with solenoid valve mounting provision )
For port T and Y................. Max. pressure is equal to tank port pressure rating
of the valve mounted.
Hydraulic medium ...................................... Mineral oil.
Viscosity range ......................................... 10 cSt to 380 cSt
Fluid temperature range ............................. -20°C to +70°C
Fluid cleanliness requirement .................... ISO 4406 20/18/15 or better.
Maximum flow handling capacity ................ For valve size
10 ..........100 l/min
20 ..........200 l/min
30 ..........400 l/min
Mass .......................................................... Refer individual table.
Port pressure is additive to the setting of the valve.
Technical specifications
Ordering code
- Proportional relief valve.
PPR 10S S 100 Y A 15
A
B
P
S
T
S
H
Y
25, 50, 100, 200 & 315, 400 bar.
Size 10, 20 & 30
Size 20 & 30
15
14
14
15
14
*
*