Speed King
®
SK200
& Valvair II
Solenoid & Pilot Operated
Directional Spool Valves
Catalog VAL-SK-E/USA
April 2004 (Revised April 2006)
Click here to view bookmarks.
(Revised 05-30-2017)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application including consequences of any failure, and review the information concerning the product or
system in the current product catalog. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document entitled “Offer of Sale”.
© Copyright 2004 Parker Hannifin Corporation. All Rights Reserved
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1
Plug-In, Manifold Mounted, 1/4" - 1-1/2" NPT Ports
Features ..................................................................................................................................2
Valve Model Number System .............................................................................................. 3-5
2-Position
Single & Double Solenoid Operated ................................................................................6-15
Single & Double Remote Air Pilot Operated...................................................................16-23
3-Position
Double Solenoid Operated.............................................................................................24-27
Double Remote Air Pilot Operated .................................................................................28-31
Manifold Ordering Procedure.................................................................................................32
Manifold Dimensional Data ...............................................................................................33-35
Modular Pneumatic Controls
“Sandwich” Regulators for 3/8" Basic Valves .................................................................36-43
Direct Pipe Ported, Inline Mounted, 1/4" - 1-1/4" NPT Ports
Features ................................................................................................................................44
Valve Model Number System ...........................................................................................45-49
2-Position
Single & Double Solenoid Operated ..............................................................................50-57
Single & Double Remote Air Pilot Operated...................................................................58-65
3-Position
Double Solenoid Operated.............................................................................................66-69
Double Remote Air Pilot Operated .................................................................................70-73
Valve Accessories ...............................................................................................................74-75
Voltage Suffix Codes ................................................................................................................75
Service Kit, Conversion Kit, “Quick Reference Guide” .............................................................76
Solenoids & Parts
Plug-In ...................................................................................................................................77
Direct Pipe Ported ............................................................................................................78-79
Optional Functions ...................................................................................................................80
Flow Capacities ...................................................................................................................81-83
Technical Information ..........................................................................................................84-87
Standard Product Crossover Information
SK-200 – 1/4" ...................................................................................................................88-89
SK-200 – 3/8" ...................................................................................................................90-91
SK-200 – 1/2" ...................................................................................................................92-93
Valvair II – 1".....................................................................................................................94-95
Specials History and Crossover Information
SK-200 – 1/4" Specials .....................................................................................................96-97
SK-200 – 3/8" Specials .....................................................................................................98-99
SK-200 – 1/2" Specials .................................................................................................100-101
Valvair II – 1" Specials .........................................................................................................102
Parker A4, A5 Series Specials Crossover Information ...........................................................103
Offer of Sale ...........................................................................................................................105
Speed King SK-200 & Valvair II Series
Table of Contents
Catalog VAL-SK-E/USA
Table of Contents
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Full Air Operation for fastest response.
Plug-ln Design simplifies maintenance and
installation. Reduces downtime. No wiring or
plumbing to disturb.
Solenoids Interchange between all styles of
plug-in valves.
Locking Manual Overrides Standard.
Non-locking overrides optional.
Indicator Lights Standard on 120VAC and
24VDC models.
Encapsulated Coil designed for low-power
consumption and maximum life.
Plug-ln Subbase, Plug-ln Manifolds allow
design flexibility. A wide range of port sizes,
from 1/4" to 1-1/4" NPT are available.
Field Convertible to External Pilot Supply for
vacuum or other services.
“Oversized” Flow Areas.
Synthetic Rubber O-Ring Seals are specially
compounded for minimum compression and
friction for superior wear and abrasion
resistance.
Precision Ground Spool “floats” on O-ring
seals. Closed center cross-over design
saves air.
Plug-ln “Sandwich” Regulators (Available for
specific models) fit between valve and base,
increase systems design capabilities.
CSA - Selected Valves are Canadian
Standards Association approved for general
purpose use.
Energized
Pressure Exhaust
Pressure Exhaust
De-Energized
2
Speed King SK-200 & Valvair II Series
“Plug-In” Style Valves
Catalog VAL-SK-E/USA
Basic Valve Features
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L4452910253
Lubricated Service
2-Position, Plug-In
1/4" Basic Size
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L6753910253
Lubricated Non-Lubricated Service
2-Position, Plug-In
3/8" & 1" Basic Size
Valvair II
Valve Model Number System
3
Speed King SK-200 & Valvair II Series
“Plug-In” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
41 Double
44 Single
Size
2 1/4" Basic
Enclosure “Class”
10 Standard
(NEMA 1 & 12)
or Remote
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC, 24VDC)
8 Solenoid w/Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
2 Standard Service
Solenoid or
Remote
4 Continuous
Service Solenoid
Operator
4 Remote
5 Solenoid
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Duty Cycle
2 Standard Service
Solenoid or
Remote
4 Continuous
Service Solenoid
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC, 24VDC)
8 Solenoid w/Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Light (120VAC, 24VDC)
& Locking Override
Enclosure “Class”
10 Standard
(NEMA 1 & 12)
or Remote
Size
3 3/8" Basic
8 1" Basic
Operator
4 Remote
5 Solenoid
Type
65 Double
67 Single
Note: Shaded options
have been discontinued.
Refer to back of Catalog
for Cross Reference
Information.
Note: Shaded options
have been discontinued.
Refer to back of Catalog
for Cross Reference
Information.
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L5155910253
Lubricated Service
2-Position, Plug-In
1/2" Basic Size
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L4252921153
Lubricated Service
3-Position, Plug-In
1/4" Basic Size
Speed King, SK-200
Valve Model Number System
4
Speed King SK-200 Series
“Plug-In” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
38 Single
(Poppet)
51 Double
54 Single
Operator
4 Remote
5 Solenoid
Size
4 * 1/2" Basic Poppet
5
1/2" Basic
Enclosure “Class”
10 Standard
(NEMA 1 & 12)
or Remote
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC, 24VDC)
8 Solenoid w/Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
2 Standard Service
Solenoid or
Remote
4 Continuous
Service Solenoid
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Type
42 Double
Size
2 1/4" Basic
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC, 24VDC)
8 Solenoid w/Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
1 Standard Service
Solenoid or
Remote
5 Continuous
Service Solenoid
Operator
4 Remote
5 Solenoid
Enclosure “Class”
21 All Ports Blocked in Neutral
(NEMA 1 & 12 Enclosure) or Remote
22 Cyl. Ports Open to Exh. in Neutral
(NEMA 1 & 12 Enclosure) or Remote
23 Cyl. Ports Open to Inlet in Neutral
(NEMA 1 & 12 Enclosure) or Remote
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Note: Shaded options
have been discontinued.
Refer to back of Catalog
for Cross Reference
Information.
Note: Shaded options have been discontinued. Refer to back
of Catalog for Cross Reference Information.
* Only available with
Type 38.
Available with Type 51
& 54.
(Revised 04/19/06)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Note: Shaded
options have been
discontinued. Refer
to back of Catalog
for Cross Reference
Information.
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L6653921153
Lubricated or Non-Lubricated Service
3-Position, Plug-In
3/8" & 1" Basic Size
Valvair II
Valve Model Number System
Basic Operator Enclosure Duty Voltage &
Series Type Operator Size Options “Class” Cycle Frequency
L5255921153
Lubricated Service
3-Position, Plug-In
1/2" Basic Size
Speed King, SK-200
Valve Model Number System
5
Speed King SK-200 & Valvair II Series
“Plug-In” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
66 Double
Operator
4 Remote
5 Solenoid
Size
3 3/8" Basic
8 1" Basic
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC,
24VDC)
8 Solenoid w/Light (120VAC,
24VDC) & Non-Locking Override
9 Solenoid w/Light (120VAC,
24VDC) & Locking Override
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Duty Cycle
1 Standard Service
Solenoid or
Remote
5 Continuous
Service Solenoid
Type
52 Double
Size
5 1/2" Basic
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
7 Solenoid w/Light (120VAC, 24VDC)
8 Solenoid w/Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
1 Standard Service
Solenoid or
Remote
5 Continuous
Service Solenoid
Operator
4 Remote
5 Solenoid
Enclosure “Class”
21 All Ports Blocked in Neutral
(NEMA 1 & 12 Enclosure) or Remote
22 Cyl. Ports Open to Exh. in Neutral
(NEMA 1 & 12 Enclosure) or Remote
23 Cyl. Ports Open to Inlet in Neutral
(NEMA 1 & 12 Enclosure) or Remote
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Enclosure “Class”
21 All Ports Blocked in
Neutral (NEMA 1 &
12 Enclosure) or
Remote
22 Cyl. Ports Open to
Exh. in Neutral
(NEMA 1 & 12
Enclosure) or Remote
23* Cyl. Ports Open to
Inlet in Neutral
(NEMA 1 & 12
Enclosure) or Remote
* Size 3 Only.
Note: Shaded options have been discontinued. Refer to back
of Catalog for Cross Reference Information.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative
flow path usages, service, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or manifold
mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve
spool to be in horizontal plane. Order from chart below.
Operation: Pressure Service
With solenoid “A” having been energized last
Pressure at Port P is connected to “Cylinder” Port A.
“Cylinder” Port B is connected to “Exhaust” Port E.
Energize solenoid “B” (momentary)
– Pressure at Port
P is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port E.
Single Solenoid Double Solenoid
Model Selection
Valve Only
Voltage
Subbase Manifold 2 Station
Manifold 3 Station
Port Size
Single Solenoid Double Solenoid
(Side Ports) (End & Bottom Ports) (End & Bottom Ports) (NPT)
L445 29 102 53 L415 29 102 53
120V 60Hz
110V 50Hz
K022 097 K142 077 K142 076 1/4"
L445 23 102
**
L415 23 102
**
Other
See page 3 for variations and (
**
) voltage codes. - Manifolds include mounting hardware.
P
AB
E
P
ASol A Sol BB
E
6
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 4-Port, 2-Position
1/4" NPT Ports, Nominal Cv = 1.4
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
EXH
CYL A CYL B
IN
EXH IN
6.65
168.9mm
2.90
73.7mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
1/2 Pipe
Conduit
Connection
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
.75
19.0mm
1.33
33.8mm
2.66
67.6mm
18
14
17
15
11
13
20
19
6.20
157.5mm
1.50
38.1mm
6.20
157.5mm
1.50
38.1mm
1.33
33.8mm
2.66
67.6mm
11
12
8
10
14
13
4 2
21
6 735 8
EXH
CYL A CYL B
SOL BSOL A
IN
EXH IN
6.74
171.2mm
3.00
76.2mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
1/2 Pipe
Conduit
Connection
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
.75
19.0mm
42 3 5 18
Single Solenoid
See Manifold Section for
Manifold Dimensional Data
Double Solenoid
See Manifold Section for
Manifold Dimensional Data
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K493 005 Spool
*5 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
13 H175 12 Lockwasher
14 H100 59 Cap Screw
17 K152 003 Override Assy.
18 K983 001 Shock Pad
* Standard Service Kit: K352 151
* Special Service Kit: K352 351
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K18R311093 Retaining Ring
3 K453 006 Spacer
*4 O-Ring
5 K453 005 Spacer
*6 Seal
7 K232 018 Spool Assy.
*8 Seal
*11 Gasket
13 H175 12 Lockwasher
14 H100 60 Cap Screw
*15 Gasket
18 K152 003 Override Assy.
19 H175 12 Lockwasher
20 H100 59 Cap Screw
21 K983 001 Shock Pad
* Standard Service Kit: K352 150
* Special Service Kit: K352 350
(Continuous Duty)
7
Speed King SK-200 Series
L445 & L415, 1/4" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1
2
Sol. A Sol. B
Wiring Diagram
3
(+)
(–)(–)
1
2
Wiring Diagram
3
(+)(–)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative
flow path usages, such as dual pressure service, see
Optional Functions
page.
Mounting
These valves are designed for subbase or manifold
mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve
spool to be in horizontal plane. Order from chart below.
Operation: Pressure Service
With solenoid “A” having been energized last
Pressure at Port P is connected to “Cylinder” Port A.
“Cylinder” Port B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary)
– Pressure at Port
P is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such
as dual pressure service, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port
A is connected to “Exhaust” Port EA.
Single Solenoid Double Solenoid
Model Selection
Valve Only
Voltage
Subbase Manifold
Port Size
Single Solenoid Double Solenoid
(Side Ports) (End & Bottom Ports) (NPT)
L675 39 102 53 L655 39 102 53
120V 60Hz
K022 090 K142 230 3/8"
110V 50Hz
K022 091 K142 231 1/2"
L675 33 102
**
L655 33 102
**
Other K022 101 K142 270 3/4"
See page 3 for variations and (
**
) voltage codes. - Manifolds include mounting hardware.
P
AB
EA EB
8
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
3/8", 1/2", 3/4 NPT Ports, Nominal Cv = 4.8
P
A B Sol ASol B
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
BACND
XP
EA
EB
7.56
192.0mm
3.32
84.3mm
1.12
28.4mm
1.12
28.4mm
2.88
73.2mm
1.44
36.6mm
2.94
74.7mm
7.38
187.5mm
3.32
84.3mm
1.12
28.4mm
1.12
28.4mm
2.94
74.7mm
2.84
72.1mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
2.00
50.8mm
1.34
34.0mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
2.00
50.8mm
2.88
73.2mm
1.44
36.6mm
2.84
72.1mm
1.34
34.0mm
6.93
176.0m
m
1.75
44.5mm
1.00
25.4mm
.34 Dia.
8.6mm
2 Holes
1/2 Pipe
Conduit
Connection
1/2 Pipe
Conduit
Connection
1/2 Pipe
Conduit
Connection
BACND
XP
EA
EB
.34 Dia.
8.6mm
2 Holes
1/2 Pipe
Conduit
Connection
SOL. B SOL. A
.62
15.7mm
.75
19.1mm
6.93
176.0mm
1.75
44.5mm
1.00
25.4mm
.62
15.7mm
.75
19.1mm
22
26
9
12
8
7 2 3 4 25 5 6
18
23
8
15
16
14
24
23
11
4 21 2 3 5 6
12
10
20
19
Double Solenoid
See Manifold Section for
Manifold Dimensional Data
Single Solenoid
See Manifold Section for
Manifold Dimensional Data
Parts List
Item
Part No. Description
No.
2 H090 71 Retaining Ring
3 K463 015 Spacer
*4 O-Ring (Dynamic)
5 K453 028 Spacer
6 K463 012 End Spacer
7 K232 020 Spool Assy.
*8 Seal
*9 Seal
*12 Gasket
14 H175 12 Lockwasher
15 H100 60 Cap Screw
*16 Gasket
22 K152 003 Override Assy.
23 H175 12 Lockwasher
24 H100 69 Cap Screw
*25 O-Ring (Static)
26 K983 002 Shock Pad
* Standard Service Kit: K352 124
* Special Service Kit: K352 125
(Continuous Duty)
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 094 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
18 K152 003 Override Assy.
19 H175 12 Lockwasher
20 H100 69 Cap Screw
*21 O-Ring (Static)
23 K983 002 Shock Pad
* Standard Service Kit: K352 126
* Special Service Kit: K352 127
(Continuous Duty)
9
Valvair II Series
L675 & L655, 3/8" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1432
(–) (+)
Wiring Diagram
12
Sol. A Sol. B
Wiring Diagram
(+) (–)
34
(+) (–)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Solenoid Double Solenoid
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or manifold
mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve spool
to be in horizontal plane. Order from chart below.
Operation: Pressure Service
With solenoid “A” having been energized last
– Pressure
at Port P is connected to “Cylinder” Port A. “Cylinder” Port
B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary)
– Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port EA.
Model Selection
Valve Only
Voltage
Subbase Manifold
Port Size
Single Solenoid Double Solenoid
(Side Ports) (End & Bottom Ports) (NPT)
L545 59 102 53 L515 59 102 53
120V 60Hz
K022 092 K142 233 1/2"
110V 50Hz
L545 53 102
**
L515 53 102
**
Other K022 093 K142 234 3/4"
See page 4 for variations and (
**
) voltage codes. - Manifolds include mounting hardware.
10
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
1/2" & 3/4" NPT Ports, Nominal Cv = 5.2
P
AB
EA EB
P
A B Sol ASol B
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 046 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
18 K152 003 Override Assy.
19 H175 16 Washer
20 H101 25 Cap Screw
21 K983 003 Shock Pad
* Standard Service Kit: K352 153
* Special Service Kit: K352 353
(Continuous Duty)
1432
(–) (+)
Wiring Diagram
12
Sol. A Sol. B
Wiring Diagram
(+) (–)
34
(+) (–)
Parts List
Item
Part No. Description
No.
2 K18R311137 Retaining Ring
3 K553 011 Washer
*4 O-Ring
5 K453 008 Spacer
6 K463 001 End Spacer
7 K232 017 Spool Assy.
*8 Seal
* 9 Seal
*12 Gasket
14 H175 12 Lockwasher
15 H100 60 Cap Screw
*16 Gasket
22 K152 003 Override Assy.
23 H175 16 Washer
24 H100 25 Cap Screw
25 K983 003 Shock Pad
* Standard Service Kit: K352 152
* Special Service Kit: K352 352
(Continuous Duty)
11
Speed King SK-200 Series
L545 & L515, 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
EXH
CYL B
CYL A
SOL. B SOL. A
EXH IN
EXH
CYL B
CYL A
EXH IN
X
X
.34 Dia.
8.6mm
2 Holes
.34 Dia.
8.6mm
2 Holes
Single Solenoid
See Manifold Section for
Manifold Dimensional Data
8.62
218.9mm
4.18
106.2mm
2.31
58.7mm
.88
22.4mm
3.25
82.6mm
1.56
39.6mm
2.69
68.3mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
1.44
36.6mm
1/2 Pipe
Conduit
Connection
8.07
205.0mm
3.83
97.3mm
1.88
47.8mm
1.31
33.3mm
3.25
82.6mm
1.56
39.6mm
3.13
79.5mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
.44
11.2mm
1.44
36.6mm
1/2 Pipe
Conduit
Connection
7.05
179.1mm
1.53
38.9 mm
7.05
179.1mm
1.53
38.9mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
Double Solenoid
See Manifold Section for
Manifold Dimensional Data
22
25
9
12
8 2 3 4 5 6
11
12
10
20
19
15
16
14
24
23
18
8
6 3 212 4 5
21
7
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Solenoid (Poppet)
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve
to base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder”
Port A is connected to “Exhaust” Port EA.
Model Selection
Valve Only
Voltage
Subbase Manifold
Port Size
Single Solenoid
(Side Ports) (End & Bottom Ports) (NPT)
L385 49 102 53
120V 60Hz
K022 092 K142 233 1/2"
110V 50Hz
L385 43 102
**
Other K022 093 K142 234 3/4"
See page 4 for variations and (
**
) voltage codes. - Manifolds include mounting hardware.
12
Speed King SK-200 Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
1/2" & 3/4" NPT Ports, Nominal Cv = 4.8
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
.34 Dia.
8.6mm
2 Holes
8.19
207.8mm
4.36
110.7mm
.88
22.4mm
2.31
58.7mm
2.69
68.3mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
.44
11.2mm
3.25
82.6mm
1.56
39.6mm
1.56
39.6mm
3.00
76.2mm
1/2 Pipe
Conduit
Connection
7.05
179.1mm
1.53
38.9mm
29
26
30
28
31
32
37
X
.50
12.7mm
.84
21.3mm
1.00
25.4mm
22
21
20
19
18
17
14 1513
119
23242524
6
5
8
7
10
12
EXH
IN
EXH
CYL ACYL B
Parts List
Item
Part No. Description
No.
* 2 Seal
4 H100 37 Cap Screw
* 5 O-Ring
* 6 O-Ring
7 K403 006 Spacer (Outer)
8 K493 018 Stem
* 9 O-Ring
10 K403 005 Spacer (Center)
*11 O-Ring
12 K18R311137 Retaining Ring
13 K313 039 Piston (Outer)
*14 O-Ring
15 H089 52 Retaining Ring
*17 O-Ring
*18 O-Ring
19 H194 32 Cap Screw
20 H178 48 Washer
*21 O-Ring
22 K313 038 Piston (Inner)
23 K473 032 Spring
24 K242 002 Poppet Assy.
25 K313 037 Piston
*26 Gasket
28 H175 12 Lockwasher
29 H100 60 Cap Screw
*30 Gasket
31 H100 69 Cap Screw
32 H175 12 Lockwasher
37 K152 003 Override
* Standard Service Kit: K352 088
* Special Service Kit: K352 089
(Continuous Duty)
See page 34 for Manifold
Dimensional Data
13
Speed King SK-200 Series
L385, 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1432
(–) (+)
Wiring Diagram
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Solenoid Double Solenoid
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or manifold
mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve spool
to be in horizontal plane. Order from chart below.
Operation: Pressure Service
With solenoid “A” having been energized last
– Pressure
at Port P is connected to “Cylinder” Port A. “Cylinder”
Port B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary)
– Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port EA.
Model Selection
Valve Only
Voltage
Subbase Manifold
Port Size Port Adapter
Single Solenoid Double Solenoid
(Side Ports) (End & Bottom Ports) (NPT) (Manifolds)
L675 89 102 53 L655 89 102 53
120V 60Hz
K022 094 K142 235 3/4"
K122 016
110V 50Hz
K022 095 K142 236 1" Kit Includes
L675 83 102
**
L655 83 102
**
Other K022 096 K142 237 1-1/4"
Both Ends
See page 3 for variations and (
**
) voltage codes. - Manifolds include mounting hardware, except for port adapters.
See chart, order separately.
14
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
3/4", 1" & 1-1/4" NPT Ports, Nominal Cv = 11.3
P
A B Sol ASol B
EA EB
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
X
EXH EXH
CYL. BCYL. A
.39 Dia.
9.9
mm
2 Holes
1/2-14 Pipe
Conduit
Connection
EXH EXH
CYL. BCYL. A
X
SOL. B SOL. A
Single Solenoid
See Manifold Section for
Manifold Dimensional Data
Double Solenoid
See Manifold Section for
Manifold Dimensional Data
10.46
265.7mm
4.75
120.6mm
1.53
38.9mm
1.53
38.9mm
4.56
115.8mm
2.28
57.9mm
3.38
85.8mm
4.28
108.7mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
2.44
62.0mm
1.53
38.9mm
1.53
38.9mm
4.56
115.8mm
2.28
57.9mm
4.28
108.7mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
2.44
62.0mm
.39 Dia.
9.9mm
2 Holes
1/2 Pipe
Conduit
Connection
8.74
222.0m
m
2.09
53.1mm
8.74
222.0m
m
2.09
53.1mm
.59
15.0mm
1.31
33.3mm
1.22
31.0mm
9.50
241.3mm
3.38
85.8mm
4.75
120.6mm
23
13
16
17
15
25
24
.59
15.0mm
1.22
31.0mm
1.31
33.3mm
12
13
11
21
20
9234 710 865
26
19
9
22
24 3 567
Parts List
Item
Part No. Description
No.
2 H090 09 Retaining Ring
3 K553 009 Spacer
*4 O-Ring (Dynamic)
*5 O-Ring (Static)
6 K453 009 Spacer
7 K463 005 End Spacer
8 K232 014 Spool Assy.
*9 O-Ring
*10 Seal
*13 Gasket
15 H175 12 Lockwasher
16 H100 60 Cap Screw
*17 Gasket
23 K152 003 Override Assy.
24 H175 20 Lockwasher
25 H101 48 Cap Screw
26 K983 004 Shock Pad
* Standard Service Kit: K352 128
* Special Service Kit: K352 129
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Dynamic)
*4 O-Ring (Static)
5 K453 009 Spacer
6 K343 061 Spool
*7 Seal
*9 Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
*13 Gasket
19 K152 003 Override Assy.
20 H175 20 Lockwasher
21 H101 48 Cap Screw
22 K983 004 Shock Pad
* Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
15
Valvair II Series
L675 & L655, 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1432
(–) (+)
Wiring Diagram
12
Sol. A Sol. B
Wiring Diagram
(+) (–)
34
(+) (–)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Model Selection
Valve Only
Subbase
Manifold (End & Bottom Ports)
Port Size
Single Solenoid Double Solenoid
(Side Ports)
2 Station 3 Station
(NPT)
L444 21 102 L414 21 102 K022 097 K142 077 K142 076 1/4"
- Manifolds include mounting hardware.
Single Remote Air Pilot Double Remote Air Pilot
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve. For
alternate flow path usages, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pilot “A” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
Pilot “B” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust” Port E.
When pressure to pilot is removed
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
16
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 4-Port, 2-Position
1/4" NPT Ports, Nominal Cv = 1.4
P
BA
E
Pilot
P
APilot A Pilot BB
E
Note: Shaded units are no longer available.
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
EXH
CYL A CYL B
IN
EXH IN
6.65
168.9mm
2.90
73.7mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
1.33
33.8mm
2.66
67.6mm
16
14
17
7 9
15
11
13
20
19
4.03
102.4mm
1.50
38.1mm
4.03
102.4mm
1.50
38.1mm
1.33
33.8mm
2.66
67.6mm
11
12
8
10
14
13
4 2
21
6 735 8
EXH
CYL A CYL B
IN
EXH IN
6.74
171.2mm
3.00
76.2mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
42 3 5 18
Single Remote
See Manifold Section for
Manifold Dimensional Data
Double Remote
See Manifold Section for
Manifold Dimensional Data
1/4 Pipe
1/4 Pipe
1/4 Pipe
PILOT
A
PILOT
B
PILOT
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K493 005 Spool
*5 Seal
7 K333 013 Plug Cap
*8 Gasket
9 K323 027 Remote Cap
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
13 H175 12 Lockwasher
14 H100 59 Cap Screw
18 K983 001 Shock Pad
* Standard Service Kit: K352 357
Parts List
Item
Part No. Description
No.
2 K18R311093 Retaining Ring
3 K453 006 Spacer
*4 O-Ring
5 K453 005 Spacer
*6 Seal
7 K232 018 Spool Assy.
*8 Seal
*11 Gasket
13 H175 12 Lockwasher
14 H100 60 Cap Screw
*15 Gasket
16 K323 027 Remote Cap
17 K333 013 Plug Cap
19 H175 12 Lockwasher
20 H100 59 Cap Screw
21 K983 001 Shock Pad
* Standard Service Kit: K352 363
17
Speed King SK-200 Series
L444 & L414, 1/4" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Remote Air Pilot Double Remote Air Pilot
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pilot “A” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Pilot “B” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
When pressure to pilot is removed
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Only
Subbase Manifold
Port Size
Single Remote Double Remote
(Side Ports) (End & Bottom Ports) (NPT)
K022 090 K142 230 3/8"
L674 31 102 L654 31 102 K022 091 K142 231 1/2"
K022 101 K142 270 3/4"
- Manifolds include mounting hardware.
18
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
3/8" Thru 3/4" NPT Ports, Nominal Cv = 4.8
P
AB
EA EB
P
AB
Pilot BPilot A
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
BACND
XP
EA
EB
2.94
74.7mm
1.44
36.6mm
2.88
73.2mm
3.32
84.3mm
1.12
28.4mm
1.12
28.4mm
7.56
192.0mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
2.94
74.7mm
1.44
36.6mm
2.88
73.2mm
3.32
84.3mm
1.12
28.4mm
1.12
28.4mm
7.56
192.0mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
4.76
120.9mm
1.75
44.5mm
4.76
120.9mm
1.75
44.5mm
2.84
71.1mm
1.34
34.0mm
.34 Dia
8.6mm
2 Holes
2.84
71.1mm
1.34
34.0mm
.34 Dia
8.6mm
2 Holes
BACND
XP
EA
EB
1/4 Pipe
1/4 Pipe
.62
15.7mm
.75
19.1mm
26
9
12
13
11
8
7 2 3 4 25 5 6
.62
15.7mm
.75
19.1mm
23
8
13
4 212 3 5 6
14
15
16
14
24
23
11
12
10
20
19
PILOT
A
PILOT
PILOT
B
Single Remote
See Manifold Section for
Manifold Dimensional Data
Double Remote
See Manifold Section for
Manifold Dimensional Data
Parts List
Item
Part No. Description
No.
2 H090 71 Retaining Ring
3 K463 015 Spacer
*4 O-Ring (Dynamic)
5 K453 028 Spacer
6 K463 012 End Spacer
7 K232 020 Spool Assy.
*8 Seal
*9 Seal
11 K333 013 Plug Cap
*12 Gasket
13 K323 027 Remote Cap
14 H175 12 Lockwasher
15 H100 60 Cap Screw
*16 Gasket
23 H175 12 Lockwasher
24 H100 69 Cap Screw
*25 O-Ring (Static)
26 K983 002 Shock Pad
* Standard Service Kit: K352 362
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 094 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
13 K323 027 Remote Cap
14 K333 013 Plug Cap
19 H175 12 Lockwasher
20 H100 69 Cap Screw
*21 O-Ring (Static)
23 K983 002 Shock Pad
* Standard Service Kit: K352 355
19
Valvair II Series
L674 & L654, 3/8" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pilot “A” pressurized last
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Pilot “B” pressurized last
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Single Remote Air Pilot Double Remote Air Pilot
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
When pressure to pilot is removed
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Only
Subbase Manifold
Port Size
Single Remote Double Remote
(Side Ports) (End & Bottom Ports) (NPT)
L544 51 102 L514 51 102
K022 092 K142 233 1/2"
K022 093 K142 234 3/4"
- Manifolds include mounting hardware.
20
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
1/2" & 3/4" NPT Ports, Nominal Cv = 5.2
P
AB
EA EB
P
AB
Pilot BPilot A
EA EB
Note: Shaded units are no longer available.
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 046 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Gasket
13 K323 027 Remote Cap
14 K333 013 Plug Cap
19 H175 16 Lockwasher
20 H101 25 Cap Screw
21 K983 003 Shock Pad
* Standard Service Kit: K352 358
Parts List
Item
Part No. Description
No.
2 K18R311137 Retaining Ring
3 K553 011 Spacer
*4 O-Ring
5 K453 008 Spacer
6 K463 001 End Spacer
7 K232 017 Spool Assy.
*8 Seal
*12 Gasket
14 H175 12 Lockwasher
15 H100 60 Cap Screw
*16 Gasket
17 K323 027 Remote Cap
18 K333 013 Plug Cap
23 H175 16 Lockwasher
24 H101 25 Cap Screw
25 K983 003 Shock Pad
* Standard Service Kit: K352 361
21
Speed King SK-200 Series
L544 & L514, 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
EXH
CYL B
CYL A
EXH IN
Single Remote
See Manifold Section for
Manifold Dimensional Data
EXH
CYL B
CYL A
EXH IN
Double Remote
See Manifold Section for
Manifold Dimensional Data
1/4 Pipe
1/4 Pipe
X
X
.34 Dia.
8.6mm
2 Holes
.34 Dia.
8.6mm
2 Holes
8.62
218.9mm
4.18
106.2mm
2.31
58.7mm
.88
22.4mm
3.25
82.6mm
1.56
39.6mm
2.69
68.3mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
1.44
36.6mm
8.07
205.0mm
3.83
97.3mm
1.88
47.8mm
1.31
33.3mm
3.25
82.6mm
1.56
39.6mm
3.13
79.5mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
.44
11.2mm
1.44
36.6mm
4.88
124.0mm
4.88
124.0mm
1.53
38.9 mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
25
9
12
17
8 2 3 4 5 6
1.53
38.9mm
11
12
10
20
19
15
18
14
16
14
24
23
8
13
6 3 212 4 5
7
PILOT
A
PILOT
B
PILOT
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Remote Air Pilot Double Remote Air Pilot
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pilot “A” pressurized last
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Pilot “B” pressurized last
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
When pressure to pilot is removed
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Only
Subbase Manifold
Port Size Port
Single Solenoid Double Solenoid
(Side Ports) (End & Bottom Ports) (NPT) Adapter
K022 094 K142 235 3/4"
K122 016
L674 81 102 K654 81 102 K022 095 K142 236 1" Kit Includes
K022 096 K142 237 1-1/4"
Both Ends
- Manifolds include mounting hardware, except for port adapters.
See chart, order separately.
22
Valvair II Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
3/4" Thru 1-1/4" NPT Ports, Nominal Cv = 11.3
P
AB
EA EB
P
AB
Pilot BPilot A
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 H090 09 Retaining Ring
3 K553 009 Spacer
*4 O-Ring (Dynamic)
*5 O-Ring (Static)
6 K453 009 Spacer
7 K463 005 Spacer
8 K232 014 Spool Assy.
*9 O-Ring
*10 Seal
*13 Gasket
14 K323 027 Remote Cap
15 H175 12 Lockwasher
16 H100 60 Cap Screw
*17 Gasket
18 K333 013 Plug Cap
24 H175 20 Lockwasher
25 H101 48 Cap Screw
26 K983 004 Shock Pad
* Standard Service Kit: K352 359
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Dynamic)
*4 O-Ring (Static)
5 K453 009 Spacer
6 K343 061 Spool
*7 Seal
*9 Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
*13 Gasket
14 K323 027 Remote Cap
15 K333 013 Plug Cap
20 H175 20 Lockwasher
21 H101 48 Cap Screw
22 K983 004 Shock Pad
* Standard Service Kit: K352 360
23
Valvair II Series
L674 & L654, 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
EXH EXH
CYL. BCYL. A
EXH EXH
CYL. BCYL. A
1/4 Pipe
1/4 Pipe
1/2-14 Pipe
Conduit
Connection
1/4 Pipe
X
.
39 Dia.
9.9mm
2 Holes
X
Single Remote
See Maniflod Section for
Manifold Dimensional Data
Double Remote
See Manifold Section for
Manifold Dimensional Data
10.46
265.7mm
4.75
120.6mm
1.53
38.9mm
1.53
38.9mm
4.56
115.8mm
2.28
57.9mm
3.38
85.8mm
4.28
108.7mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
2.44
62.0mm
1.53
38.9mm
1.53
38.9mm
4.56
115.8mm
2.28
57.9mm
4.28
108.7mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
2.44
62.0mm
.39 Dia.
9.9mm
2 Holes
6.57
166.9m
m
2.09
53.1mm
6.57
166.9m
m
2.09
53.1mm
.59
15.0mm
1.31
33.3mm
1.22
31.0mm
9.50
31.0mm
3.38
85.8mm
4.75
120.6mm
13
.59
15.0mm
1.22
31.0mm
1.31
33.3mm
14
16
17
15
25
24
12
13
11
21
20
9234 710 865
26
9
14
22
15
18
24 3 567
PILOT
A
PILOT
B
PILOT
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1/4" Basic, Nominal Cv = 1.4 1/2" Basic, Nominal Cv = 5.0
Application
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement is
desired. A “momentary” (exceeding .03 seconds) or
maintained electrical signal applied to one of the
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed.
Valve may be applied for alternate service. For alternate
flow path usages, see
Optional Functions
page.
Operation: Pressure Service
Neutral “Class 21”
Both solenoids de-energized (Normal Condition)
All ports blocked.
Neutral “Class 22” (L525 Only)
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to “Exhaust” Port E (EA),
“Cylinder” Port B is open to “Exhaust” Port E (EB),
“Pressure” Port P is blocked.
Neutral “Class 23”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to Pressure Port P, “Cylinder”
Port B is open to Pressure Port P. Both “Exhaust”
Port(s) E (EA and EB) are blocked.
Activated Operation
With solenoid “A” energized
– Pressure at Port P flows
to “Cylinder” Port A, “Cylinder” Port B is connected to
“Exhaust” Port E (EB), regardless of neutral “class”.
With solenoid “B” energized
– Pressure at Port P flows to
“Cylinder” Port B, “Cylinder” Port A is connected to
“Exhaust” Port E (EA), regardless of “neutral”
configuration.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Model Selection (Neutral “Class 21” Shown)
Valve Only Voltage
Subbase
Manifold (End & Bottom Ports)
Port Size
(Side Ports)
2 Station 3 Station Modular
(NPT)
L425 29 211 53
120V 60Hz
110V 50Hz
K022 097 K142 077 K142 076 1/4"
L425 23 211
**
Other
L525 59 211 53
120V 60Hz
K022 092 K142 233 1/2"
110V 50Hz
L525 53 211
**
Other K022 093 K142 234 3/4"
See page 4 & 5 for variations in class of neutral configuration and (
**
) voltage codes. - Manifolds include mounting hardware.
1/4" Basic 1/2" Basic
24
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
Solenoid Operated
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4", 1/2" & 3/4" NPT Ports
P
AB
AB
AB
E
P
E
P
E
P
ASol B Sol A
Sol B Sol A
Sol B Sol A
B
EA EB
P
A
B
EA EB
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
24
6.20
157.5mm
1.50
38.1mm
1.33
33.8mm
2.66
67.6mm
18
21
15
17
19
20
EXH
CYL A CYL B
SOL BSOL A
IN
EXH IN
9.43
239.5mm
4.34
110.2mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
1/2 Pipe
Conduit
Connection
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
.75
19.0mm
1/4" Basic
See Manifold Section for
Manifold Dimensional Data
1/2" Basic
See Manifold Section for
Manifold Dimensional Data
EXH
CYL B
CYL A
SOL. B SOL. A
EXH IN
42 3 58 979
X
.34 Dia.
8.6mm
2 Holes
11.11
282.2mm
5.56
141.2mm
1.88
47.8mm
1.31
33.3mm
3.25
82.6mm
1.56
39.6mm
3.13
79.5mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
.44
11.2mm
1.44
36.6mm
1/2 Pipe
Conduit
Connection
7.05
179.1mm
1.53
38.9mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
17
18
16
26
25
24
14
9810 32 4 5
628
6
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K343 020 Spool
(All Ports Blocked)
4 K343 073 Spool (Cyl. Ports
Open to Exh.)
4 K343 021 Spool (Cyl. Ports
Open to Inlet)
5 K313 009 Piston (Long)
6 K313 010 Piston (Short)
*7 Seal
*8 Seal
*9 Seal
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
19 H100 59 Cap Screw
20 H175 12 Lockwasher
*21 Gasket
24 K152 003 Override Assy.
* Standard Service Kit: K352 151
* Special Service Kit: K352 351
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 045 Spool
(All Ports Blocked)
5 K343 067 Spool (Cyl. Ports
Open to Inlet)
5 K343 068 Spool (Cyl. Ports
Open to Exh.)
*6 Seal
*8 Seal
9 K313 017 Piston
*10 Seal
*14 Gasket
16 H175 12 Lockwasher
17 H100 60 Cap Screw
*18 Gasket
24 K152 003 Override Assy.
25 H175 16 Lockwasher
26 H101 25 Cap Screw
28 K983 003 Shock Pad
* Standard Service Kit: K352 153
* Special Service Kit: K352 353
(Continuous Duty)
25
Speed King SK-200 Series
L425 & L525, 1/4" & 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
12
Sol. A Sol. B
Wiring Diagram
(+) (–)
34
(+) (–)
1
2
Sol. A Sol. B
Wiring Diagram
3
(+)
(–)(–)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
3/8" Basic, Nominal Cv = 4.8 1" Basic, Nominal Cv = 11.3
Application
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement
is desired. A “momentary” (exceeding .03 seconds) or
maintained electrical signal applied to one of the
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed.
Valve may be applied for alternate service. For alternate
flow path usages, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to
base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
Operation: Pressure Service
Neutral “Class 21”
Both solenoids de-energized (Normal Condition)
All ports blocked.
Neutral “Class 22”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to “Exhaust” Port EA, “Cylinder”
Port B is open to “Exhaust” Port EB, “Pressure”
Port P is blocked.
Neutral “Class 23”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to Pressure Port P, “Cylinder”
Port B is open to Pressure Port P. Both “Exhaust”
Ports EA and EB are blocked.
Activated Operation
With solenoid “A” energized
– Pressure at Port P flows
to “Cylinder” Port A, “Cylinder” Port B is connected to
“Exhaust” Port EB, regardless of neutral “class”.
With solenoid “B” energized
– Pressure at Port P flows to
“Cylinder” Port B, “Cylinder” Port A is connected to
“Exhaust” Port EA, regardless of neutral “class”.
Model Selection (Neutral “Class 21” Shown)
Valve Only Voltage
Subbase Manifold
Port Size Port
(Side Ports) (End & Bottom Ports) (NPT) Adapter
L665 39 211 53
120V 60Hz
K022 090 K142 230 3/8"
110V 50Hz
K022 091 K142 231 1/2" Not Req’d
L665 33 211
**
Other K022 101 K142 270 3/4"
L665 89 211 53
120V 60Hz
K022 094 K142 235 3/4"
K122 016
110V 50Hz
K022 095 K142 236 1" Kit Includes
L665 83 211
**
Other K022 096 K142 237 1-1/4"
Both Ends
See page 5 for variations in class of neutral configuration - Manifolds include mounting hardware, except for port adapters.
and (
**
) voltage codes. See chart, order separately.
26
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
Solenoid Operated
4-Way, 5-Port, 3-Position - 3/8" Thru 1-1/4" NPT Ports
P
ASol B Sol A
Sol B Sol A
Sol B Sol A
B
EA EB
P
A
B
EA EB
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
BACND
XP
EA
EB
9.64
244.8mm
4.82
122.4mm
1.12
28.4mm
1.12
28.4mm
2.88
73.2mm
1.44
36.6mm
2.94
74.7mm
2.84
72.1mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
2.00
50.8mm
1.34
34.0mm
6.93
176.0m
m
1.75
44.5mm
1.00
25.4mm
.34 Dia.
8.6mm
2 Holes
1/2 Pipe
Conduit
Connection
13.62
345.9mm
6.81
173.0mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
3.38
85.8mm
4.56
115.8mm
2.44
62.0mm
4.28
108.7mm
1.53
38.9mm
1.53
38.9mm
.39 Dia.
9.9mm
3 Holes
1/2 Pipe
Conduit
Connection
.62
15.7mm
.75
19.1mm
24
14
17
18
16
26
25
8.74
222.0mm
2.09
53.1mm
18
19
17
27
26
29
81096 623427305
3/8
"
Basic
See Manifold Section for
Manifold Dimensional Data
1
"
Basic
See Manifold Section for
Manifold Dimensional Data
1/2-14 Pipe
Conduit
Connection
EXH EXH
CYL. BCYL. A
SOL. B SOL. A
SOL. B SOL. A
X
.59
15.0mm
1.22
31.0mm
1.31
33.3mm
25
15
29
23 4 561011 9 7
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 124 Spool
(All Ports Blocked)
5 K343 126 Spool (Cyl. Ports
Open to Inlet)
5 K343 125 Spool (Cyl. Ports
Open to Exh.)
*6 Seal
*8 Seal
9 K313 049 Piston
*10 Seal
*14 Gasket
16 H175 12 Lockwasher
17 H100 60 Cap Screw
*18 Gasket
24 K152 003 Override Assy.
25 H175 12 Lockwasher
26 H100 69 Cap Screw
*27 O-Ring (Static)
29 K983 002 Shock Pad
30 K983012 Bumper Pad
* Standard Service Kit: K352 126
* Special Service Kit: K352 127
(Continuous Duty)
#30 K983012 Bumper Pad goes with
Item # 5.
Purchase Item #30 as well.
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Static)
*4 O-Ring (Dynamic)
5 K453 009 Spacer
6 K343 060 Spool
(All Ports Blocked)
6 K343 070 Spool (Cyl. Ports
Open to Exh.)
6 K343 069 Spool (Cyl. Ports
Open to Inlet)
*7 Seal
*9 Seal
10 K313 023 Piston
*11 Seal
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
*19 Gasket
25 K152 003 Override Assy.
26 H175 20 Washer
27 H101 48 Cap Screw
29 K983 004 Shock Pad
* Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
27
Valvair II Series
L665, 3/8" & 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
(Revised 12-7-07)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1/4" Basic, Nominal Cv = 1.4
Application
These valves may be used to actuate double acting
cylinders when “inching” or incremental rod movement
is desired. A normally open pilot signal to both pilot caps
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate service. For alternate
flow path usages, see
Optional Functions
page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Neutral “Class 21”
Normally open pilot signals to both pilot caps
All ports blocked.
Neutral “Class 22”
Normally open pilot signals to both pilot caps
– “Cylinder”
Port A is connected to “Exhaust” Port E (EA) and
“Cylinder” Port B is connected to “Exhaust” Port E (EB).
Pressure at Port P is blocked.
Neutral “Class 23”
Normally open pilot signals to both pilot caps
– “Cylinder”
Ports A and B are connected to Port P. “Exhaust” Port(s)
E (EA and EB) are blocked.
Activated Operation
When Pilot “A” is exhausted
– Pressure at Port P is
connected to “Cylinder” Port A. “Exhaust” Port E (EB) is
connected to “Cylinder” Port B.
When Pilot “B” is exhausted
– Pressure at Port P is
connected to “Cylinder” Port B, “Exhaust” Port E (EA) is
connected to “Cylinder” Port A.
1/2" Basic, Nominal Cv = 5.0
Model Selection
Valve Only
Subbase
Manifold (End & Bottom Ports)
Port Size
(Side Ports)
2 Station 3 Station Modular
(NPT)
L424 21 211 K022 097 K142 077 K142 076 1/4"
L524 51 211
K022 092 K142 233 1/2"
K022 093 K142 234 3/4"
See page 4 & 5 for variations in class of neutral configurations. - Manifolds include mounting hardware.
1/4" Basic 1/2" Basic
28
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
Remote Air Pilot Operated
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4", 1/2" & 3/4" NPT
Ports
P
AB
EA EB
Pilot B Pilot A
Pilot B Pilot A
Pilot B Pilot A
P
AB
EBEA
P
AB
EA EB
Pilot A
Pilot A
Pilot A
Pilot B
Pilot B
Pilot B
P
AB
AB
AB
E
P
E
P
E
Note: Shaded units are no longer available.
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
4.03
102.4mm
1.50
38.1mm
1.33
33.8mm
2.66
67.6mm
18
21
15
17
19
20
EXH
CYL A CYL B
IN
EXH IN
9.43
239.5mm
4.34
110.2mm
.56
14.2mm
.56
14.2mm
3.31
84.1mm
2.20
55.9mm
1.22
31.0mm
.27 Dia.
6.8mm
2 Holes
2.19
55.6mm
1.09
27.7mm
.97
24.6mm
1/4" Basic
See Manifold Section for
Manifold Dimensional Data
1/2" Basic
See Manifold Section for
Manifold Dimensional Data
EXH
CYL B
CYL A
EXH IN
42 3 58 979
X
.34 Dia.
8.6mm
2 Holes
11.11
282.2mm
5.56
141.2mm
1.88
47.8mm
1.31
33.3mm
3.13
79.5mm
3.00
76.2mm
6.25
158.8mm
3.25
82.6mm
1.62
41.1mm
2.03
51.6mm
.44
11.2mm
1.44
36.6mm
3.25
82.6mm
1.56
39.6mm
1/2 Pipe
Conduit
Connection
4.88
124.0mm
1.53
38.9mm
.50
12.7mm
.84
21.3mm
1.00
25.4mm
17
13
15
10
11
28
18
16
26
25
14
9810 32 4 5
6
6
1/4 Pipe
1/4 Pipe
1/4 Pipe
1/4 Pipe
1/2 Pipe
Conduit
Connection
.75
19.0mm
PILOT
A
PILOT
B
PILOT
B
PILOT
A
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K343 020 Spool
(All Ports Blocked)
4 K343 021 Spool (Cyl. Ports
Open to Inlet)
4 K343 073 Spool (Cyl. Ports
Open to Exh.)
5 K313 009 Piston (Long)
6 K313 010 Piston (Short)
*7 Seal
*8 Seal
*9 Seal
10 K323 027 Remote Cap
11 K333 013 Plug Cap
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
19 H100 59 Cap Screw
20 H175 12 Lockwasher
*21 Gasket
* Standard Service Kit: K352 357
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 045 Spool
(All Ports Blocked)
5 K343 067 Spool (Cyl. Ports
Open to Inlet)
5 K343 068 Spool (Cyl. Ports
Open to Exh.)
*6 Seal
*8 Seal
9 K313 017 Piston
*10 Seal
13 K323 027 Remote Cap
*14 Gasket
15 K333 013 Plug Cap
16 H175 12 Lockwasher
17 H100 60 Cap Screw
*18 Gasket
25 H175 16 Lockwasher
26 H101 25 Cap Screw
28 K983 003 Shock Pad
* Standard Service Kit: K352 358
29
Speed King SK-200 Series
L424 & L524, 1/4" & 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to activate double acting
cylinders when “inching” or incremental rod movement is
desired. A normally open pilot signal to both pilot caps
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate services. For alternate
flow path usages, see
Optional Functions
page.
Mounting
3/8" Basic, Nominal Cv = 4.8 1" Basic, Nominal Cv = 11.3
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Operation: Pressure Service
Neutral “Class 21”
Normally open pilot signals to both pilot caps
All ports blocked.
Neutral “Class 22”
Normally open pilot signals to both pilot caps
“Cylinder” Port A is connected to “Exhaust” Port EA
and “Cylinder” Port B is connected to “Exhaust” Port EB.
Pressure at Port P is blocked.
Neutral “Class 23”
Normally open pilot signals to both pilot caps
“Cylinder” Ports A & B are connected to Port P.
“Exhaust” Ports EA & EB are blocked.
Activated Operation
When Pilot “A” is exhausted
– Pressure at Port P is
connected to “Cylinder” Port A. “Exhaust” Port EB is
connected to “Cylinder” Port B.
When Pilot “B” is exhausted
– Pressure at Port P is
connected to “Cylinder” Port B. “Exhaust” Port EA is
connected to “Cylinder” Port A.
Model Selection (Neutral “Class 21” Shown)
Valve Only
Subbase Manifold
Port Size Port
(Side Ports) (End & Bottom Ports) (NPT) Adapter
K022 090 K142 230 3/8"
L664 31 211 K022 091 K142 231 1/2" Not Req’d
K022 101 K142 270 3/4"
K022 094 K142 235 3/4"
K122 016
L664 81 211 K022 095 K142 236 1" Kit Includes
K022 096 K142 237 1-1/4"
Both Ends
See page 5 for variations in class of neutral configurations. - Manifolds include mounting hardware.
30
Valvair II Series
Lubricated & Non-Lubricated Service
Catalog VAL-SK-E/USA
Remote Air Pilot Operated
4-Way, 5-Port, 3-Position - 3/8" Thru 1-1/4" NPT Ports
P
AB
EA EB
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
P
AB
EBEA
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 124 Spool
(All Ports Blocked)
5 K343 126 Spool (Cyl. Ports
Open to Inlet)
5 K343 125 Spool (Cyl. Ports
Open to Exh.)
*6 Seal
*8 Seal
9 K313 049 Piston
*10 Seal
*14 Gasket
15 K323 027 Remote Cap
16 H175 12 Lockwasher
17 H100 60 Cap Screw
*18 Gasket
25 H175 12 Lockwasher
26 H100 69 Cap Screw
*27 O-Ring (Static)
28 K333 013 Plug Cap
29 K983 002 Shock Pad
* Standard Service Kit: K352 355
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Static)
*4 O-Ring (Dynamic)
5 K453 009 Spacer
6 K343 060 Spool
(All Ports Blocked)
6 K343 070 Spool (Cyl. Ports
Open to Exh.)
6 K343 069 Spool (Cyl. Ports
Open to Inlet)
*7 Seal
*9 Seal
10 K313 023 Piston
*11 Seal
14 K323 027 Remote Cap
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
*19 Gasket
26 H175 20 Lockwasher
27 H101 48 Cap Screw
28 K333 013 Plug Cap
29 K983 004 Shock Pad
* Standard Service Kit: K352 360
31
Valvair II Series
L664, 3/8" & 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
BACND
XP
EA
EB
D
9.64
244.8mm
4.82
122.4mm
1.12
28.4mm
1.12
28.4mm
2.88
73.2mm
1.44
36.6mm
2.94
74.7mm
2.84
72.1mm
6.03
153.2mm
3.16
80.3mm
2.00
50.8mm
.38
9.7mm
.75
19.1mm
2.00
50.8mm
1.34
34.0mm
4.76
120.9 mm
1.75
44.5mm
.34 Dia.
8.6mm
2 Holes
13.62
345.9mm
6.81
173.0mm
7.62
193.5mm
3.81
96.8mm
2.46
62.5mm
2.45
62.2mm
3.38
85.8mm
4.56
115.8mm
2.44
62.0mm
4.28
108.7mm
1.53
38.9mm
1.53
38.9mm
.39 Dia.
9.9mm
2 Holes
.62
15.7mm
.75
19.1mm
14
15
17
1/4 Pipe1/4 Pipe
18
16
26
25
6.57
166.8mm
2.09
53.1mm
18
19
17
27
26
29
19
81096 6234275
3/8
"
Basic
See Manifold Section for
Manifold Dimensional Data
1
"
Basic
See Manifold Section for
Manifold Dimensional Data
EXH EXH
CYL. BCYL. A
X
.59
15.0mm
1.22
31.0mm
1.31
33.3mm
15
14
29
28
23 4 561011 9 7
1/4 Pipe
1/4 Pipe
PILOT
B
PILOT
A
PILOT
B
PILOT
A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
When Ordering Valve & Manifold Assemblies
1. Factory assembly instructions – valve & manifold (or subbase) to be assembled. Sequence of
assembly to be as listed on order (see example) from left to right when facing end cylinder ports.
2. Size – identified as 5th character in Valve Model Number.
2 = 1/4" Basic L 2
3 = 3/8" Basic L 3
5 = 1/2" Basic L 5
8 = 1" Basic L 8
(Port Plate K122 016 required on multi-station assemblies)
3. Number of stations:
00 = Single Subbase
01 = Single (Modular) Manifold (Do not use with 1/4" Basic Size)
02 = 2-Station
* 12 = 12-Station
*
More stations may be added, if there is sufficient upstream volume and pressure to insure that the last valve in the
assembly will function. An increased upstream volume, conversion to an external pilot, or an additional inlet may
prevent “starvation” problems on larger assemblies.
Manifold Assembly K163303
–––––––––
1. Number of Stations
2. Valve Size
3. Factory Assembly
Example:
L515 59 102 53
K022 092
K163
500
List items to be assembled as
ordered Pairs and in “Sequence” of
Assembly.
E
xample:
L675 39 102 53
K142 230
L655
39 102 53
K142 231
L665
39 102 53
K142 270
K163
303
¬¬
¬¬
¬
¬¬
¬¬
¬
32
Speed King SK-200 & Valvair II Series
Valve & Manifold Assemblies
Catalog VAL-SK-E/USA
Ordering Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
LEFT RIGHT
EXH INLET CONDUIT
6.38
162.1mm
2.22
56.4mm
4.30
109.2mm
Sing.
Sol.
4.40
111.8mm
Dbl.
Sol.
5.56
141.2mm
2.50
63.5mm
4.50
114.3mm
.41 Dia.
10.4mm
2 Holes
1.81
46.0mm
1.00
25.4mm
1.00
25.4mm
.50
12.7mm
CYL. A
CYL. A
CYL. B
CYL. B
LEFT RIGHTCENTER
EXH INLET CONDUIT
7.31
185.7mm
.41 Dia.
10.4mm
2 Holes
4.30
109.2mm
Sing.
Sol.
4.40
111.8mm
Dbl.
Sol.
5.56
141.2mm
2.22
56.4mm
.50
12.7mm
9.19
233.4mm
2.50
63.5mm
.50
12.7mm
1.81
46.0mm
1.81
46.0mm
1.00
25.4mm
1.00
25.4mm
1.00
25.4mm
CYL. A
CYL. A
CYL. B
CYL. A
CYL. B
CYL. B
.41 Dia.
10.4mm
2 Holes
2.00
50.8mm
1/4 N.P.T.F.
2.00
50.8mm
7.20
182.9mm
1.38
35.1mm
1.25
31.8mm
1.25
31.8mm
1.75
44.4mm
3.47
88.1mm
6.62
168.1mm
7.38
187.4mm
2.06
52.3mm
.38
9.6mm
.84
21.3mm
K142-077 Two-Station Manifold
K142-076 Three-Station Manifold
Suitable for mounting any combination of 1/4",
4-Way single or double solenoid Plug-In Valves.
Common inlet, exhaust and electrical conduit ports
simplify installation.
Tapped for side or bottom cylinder port connections.
Ganging manifolds end-to-end permits manifolding
any desired number of valves.
Integral Plug-In connections for safe, simple
electrical connection of valve and manifold.
Plug-In Manifold
Cylinder Ports ................................................... 1/4" NPTF
Exhaust Port ..................................................... 1/2" NPTF
Inlet Port ........................................................... 1/2" NPTF
Conduit Port .................................................. 1-1/4" NPTF
33
Speed King SK-200 Series
Plug-in Manifolds, 1/4" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
7.97
202.4mm
7.56 (Sing Sol)
192.0mm
6.64 (Dbl Sol)
168.7mm
4.76 (Sing Sol)
121.0mm
3.83 (Dbl Sol)
97.3mm
3.32
84.3mm
8.05
204.5mm
8.44
214.5mm
1.38
34.9mm
1.69
42.9mm
3.38
85.7m
m
5.00
127.0mm
3.19
81.0mm
.34
8.6mm
.61
15.5mm
1.19
30.2mm
1.09
27.7mm
1.81
46.0mm
1.91
48.5mm
8.44
214.5mm
5.00
127.0mm
3.19
81.0mm
2.00
50.8mm
1.19
30.2mm
1.06
27.0mm
.72
18.3mm
.75
19.1mm
.19
4.8mm
1.41
35.7mm
.41
10.3mm
1.91
48.5mm
2.06
52.3mm
1.41
35.8mm
.75
19.1mm
2.09
53.1mm
.75
19.1mm
.59
15.0mm
2.56
65.0mm
(Flange
Height)
.33 Dia.
8.3mm
2 Holes
.39 Dia.
9.9mm
2 Holes
.39 Dia.
9.9mm
2 Holes
.33 Dia.
8.4mm
2 Holes
1/4
Pipe
1/4
Pipe
1.66
42.2mm
Typ. For
Bottom Ports
8.26
210.0mm
Bottom
Cyl.
Ports
2.09
53.1mm
.84
21.4mm
3.03
77.0mm
(Flange
Height)
1.69
42.9mm
Bottom Cyl. Ports
& Ext. Pilot Supply
B
AP
E
XCND
CND
IN
AB
EXH
CYL A
CYL B
4.34
110.2mm
8.00
203.2mm
5.16
131.0mm
9.09
231.0mm
4.78
121.4mm
3.00
76.2mm
1.24
31.5mm
1.50
38.1mm
9.09
230.9mm
3/8" Basic
K142 230 Cyl. Ports 3/8" NPTF
K142 231 Cyl. Ports 1/2" NPTF
K142 270 Cyl. Ports 3/4" NPTF
Exhaust Port .............................. 1" NPTF
Inlet Port .................................... 1" NPTF
Conduit Port ......................... 1-1/4" NPTF
Note:
Manifold assemblies include mounting hardware.
1/2" Basic
K142 233 Cyl. Ports 1/2" NPTF
K142 234 Cyl. Ports 3/4" NPTF
Exhaust Port .............................. 1" NPTF
Inlet Port .................................... 1" NPTF
Conduit Port ......................... 1-1/4" NPTF
Note:
Manifold assemblies include mounting hardware.
34
Speed King SK-200 & Valvair II Series
3/8" & 1/2" Basic Valve
Catalog VAL-SK-E/USA
Plug-in Manifold Dimensional Data
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1" Basic
K142 235 Cyl. Ports 3/4" NPTF
K142 236 Cyl. Ports 1" NPTF
K142 237 Cyl. Ports 1-1/4" NPTF
K122 016 End Plate Kit (Both Plates)
Exhaust Port ........................1-1/2" NPTF (Port Plate)
Inlet Port ..............................1-1/2" NPTF (Port Plate)
Conduit Port ......................... 1-1/4" NPTF (Port Plate)
X
A
B
P
EA EB
Pipe Adaptor
(End Valves Only)
11.72
297.7mm
6.21
157.7mm
2.44
62.0mm
.12
3.0mm
4.25
108.0mm
10.36
263.1mm
2.85
72.4 mm
1.75
44.4 mm
2.00
50.8 mm
2.44
62.0 mm
1.22
31.0 mm
1.28
32.5 mm
1.75
44.4mm
3.03
77.0mm
12.81
325.4mm
12.06
306.4mm
6.41
162.8mm
6.03
153.2mm
5.31
134.9mm
4.81
122.2mm
2.50
63.5mm
2.50
63.5mm
4.38
111.2mm
3.34
84.8mm
10.62
269.9mm
.25
6.4mm
1.53
38.9mm
2.00
50.8mm
6.28
159.5mm
4.88
124mm
5.69
144.5mm
1.19
30.2mm
.406 Dia.
10.3mm
2 Holes
.39 Dia.
9.9mm
4 Holes
Bottom
Cyl. Ports
Typ. For
Bottom Ports
1/4 Pipe
5.71 (Sing Sol)
145.0mm
4.75 (Dbl Sol)
120.6mm
35
Valvair II Series
1" Basic Valve
Catalog VAL-SK-E/USA
Plug-in Manifold Dimensional Data
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Modular Pneumatic Controls
Plug-In Sandwich Block Design
for Modular Port Regulation
These modular regulators assemble to any 3/8" basic
valve interface pattern.
Port Regulation Made Easy
Place the sandwich on the manifold or subbase, tighten
the four securing screws, then plug the valve into the
sandwich and tighten its securing screws to complete the
assembly.
Within minutes, these modular components can be
installed in new, or used to improve existing manifold
systems, without disturbing wiring or air connections.
3-Configurations
1. Common Port Regulation - A common regulated
pressure is selected to both cylinder ports.
2. Single Port Regulation - Line pressure is available to
one cylinder port, while a single regulated pressure is
selected to the other cylinder port.
3. Independent Port Regulation - Two independently
regulated pressures selected to the cylinder ports.
NOTE: When using single or independent port sandwich
regulators, be aware that:
1. Cylinder port outlets are reversed.
2. 3-Position, cylinder ports open to exhaust and cylinder
ports open to inlet functions are reversed. To produce
a cylinder ports open to exhaust function, order valve
with cylinder ports open to inlet. To produce a cylinder
ports open to inlet function, order valve with cylinder
ports open to exhaust.
Manual or Remote secondary pressure adjustment.
Three Pressure Ranges are standard for manual
units:
1-30 psig
1-60 psig
2-125 psig.
Range for Remote: 0-140 psig
Gauges are furnished standard, liquid filled gauges
are optional.
Typical Assembly
Regulator
Assembly
Manifold
Solenoid Valve
Assembly
36
Valvair II Series
Modular Plug-In Regulators
Catalog VAL-SK-E/USA
Features
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
The above curves illustrate flow characteristics through an assembled valve,
air regulator, and base (or modular manifold) unit.
FLOW - SCFM
0
0
RELIEF AND FLOW CHARACTERISTICS
COMMON PORT REGULATION
SECONDARY PRESSURE - PSIG
10 20 4030 6050 8070 90
FLOW - dm
3
/S
n
0
SECONDARY PRESSURE - bar
20
10
60
50
80
90
70
40
30
100
1
2
3
4
5
6
10 110 120100 130
0 5 10 4540 6055505 15 20 25 30 35
R
ELIEF AND FLOW CHARACTERISTICS
INDEPENDENT OR SINGLE PORT REGULATION
FLOW - SCFM
0
0
SECONDARY PRESSURE - PSIG
10 20 4030 6050 8070 90
FLOW - dm
3
/S
n
0
SECONDARY PRESSURE - bar
20
10
60
50
80
90
70
40
30
100
1
2
3
4
5
6
100 PSIG (6.9 bar) PRIMARY PRESSURE
10 110 120100 130
0 5 10 4540 6055505 15 20 25 30 35
100 PSIG (6.9 bar) PRIMARY PRESSURE
37
Valvair II Series
L554, 3/8" Basic Valve
Catalog VAL-SK-E/USA
Relief & Flow Characteristics
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Function
This modular air pressure regulator assembly, installed
between a 3/8" basic, 4-Way valve and subbase, supplies
regulated pressures to both cylinder ports.
Valve must be converted to external pilot supply.
Features
Regulated pressure output from the valve is adjusted
by knob on the manually set model or by air pressure
signal applied to the regulator pilot port on the remotely
set model.
Furnished with pressure gauge as standard.
Assembly “A” (Shown at right) or Assembly “B” may be
specified as a matter of convenience, or to satisfy space
limitations.*
Pressure Range Options
Maximum Supply Pressure .................................. 140 psi
Output Pressure Range..................................... 1 - 30 psi
1 - 60 psi
2 - 125 psi
Operating Temperature Range
32°F (0°C) to 175°F (79°C)
How To Order
1. Select type of adjustment
2. Select pressure range
3. Select assembly style
Example:
Manual adjusted.
1-60 psi with regulator positioned over the
junction box.
Model No. L554 08 302C
Assembly “A”
Pressure
Pressure
Model Number
Adjustment
Range
psi Assembly “A” Assembly “B”
1 - 30 L554 01 308C L554 08 301C
Manual 1 - 60 L554 02 308C L554 08 302C
2 - 125 L554 03 308C L554 08 303C
Manual with
1 - 30 L554 27 308C L554 08 327C
Liquid Filled 1 - 60 L554 28 308C L554 08 328C
Gauges
2 - 125 L554 29 308C L554 08 329C
Remote 0 - 140 L554 11 308C L554 08 311C
Remote with
Liquid Filled 0 - 140 L554 35 308C L554 08 335C
Gauges
* Assembly “A” places the regulator on the end opposite the
electrical junction box. Assembly “B” places the regulator over the
electrical junction box.
See page 43 for gauges.
Graphic Symbol
Regulated Pressure at
Both “A” & “B”
BA
EXEX
SUPPLY
PRESSURE
38
Valvair II Series
Plug-In Regulators
Catalog VAL-SK-E/USA
Common Port Regulation
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Function
This modular air pressure regulator assembly, when installed
between a 3/8" basic, 4-Way valve and subbase or modular
manifold, supplies one or more regulated pressures to one of the
valve cylinder ports and supply pressure to the other cylinder
port.
On Single Port Cylinder Port Regulation Units controlled by a
single solenoid valve, cylinder port “B” is the normally open
cylinder port. The solenoid is energized to open cylinder Port “A”.
On double solenoid operated valves, energizing solenoid “B”
opens cylinder port “A” and energizing solenoid “A” opens
cylinder port “B”.
Valve must be converted to external pilot supply.
Features
Regulated pressure output from the valve is adjusted by knob on
the manually set model or by air pressure signal applied to the
regulator pilot port on the remotely set model.
For reduced pressure at “A” cylinder port, the regulator is
mounted per assembly “A” on end opposite the electrical junction
box. For reduced pressure at “B” cylinder port the regulator is
mounted per Assembly “B” which places the regulator over the
electrical junction box.
Furnished with pressure gauge as standard.
Pressure Range Options
Maximum Supply Pressure .............................................. 140 psi
Output Pressure Range ................................................1 - 30 psi
1 - 60 psi
2 - 125 psi
Operating Temperature Range
32°F (0°C) to 175°F (79°C)
How To Order
1. Select type of adjustment desired
2. Select pressure range
3. Select working port for reduced pressure
Example:
Manual adjustment, 5-60 psi, Port A reduced.
Model No. L554 05 307C
Assembly “A”
Pressure
Pressure
Model Number
Adjustment
Range
Reduced Pressure
psi Cyl. Port “A” Cyl. Port “B”
1 - 30 L554 04 307C L554 07 304C
Manual 1 - 60 L554 05 307C L554 07 305C
2 - 125 L554 06 307C L554 07 306C
Manual with
1 - 30 L554 30 307C L554 07 330C
Liquid Filled 1 - 60 L554 31 307C L554 07 331C
Gauges
2 - 125 L554 32 307C L554 07 332C
Remote 0 - 140 L554 14 307C L554 07 314C
Remote with
Liquid Filled 0 - 140 L554 38 307C L554 07 338C
Gauges
Note: Shaded units are no longer available.
Note: When using single or independent port sandwich regulators,
be aware that:
1. Cylinder port outlets are reversed.
2. 3-Position, cylinder ports open to exhaust and cylinder ports open
to inlet functions are reversed. To produce a cylinder ports open to
exhaust function, order valve with cylinder ports open to inlet. To
produce a cylinder ports open to inlet function, order valve with
cylinder ports open to exhaust.
See page 43 for gauges.
Graphic Symbol
Supply Pressure at “B” Supply Pressure at “A”
& Regulated at “A” & Regulated at “B”
BA
SUPPLY
PRESSURE
EX
BA
SUPPLY
PRESSURE
EX
39
Valvair II Series
Plug-In Regulators
Catalog VAL-SK-E/USA
Single Port Regulation
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Function
This modular air pressure regulation assembly, when
installed between a 3/8" basic, 4-Way valve and subbase
or modular manifold, supplies one or more regulated
pressures to each of the valve cylinder ports.
Regulated pressure to cylinder port “A”, and a second
regulated pressure to cylinder port “B”; independently
adjustable.
On Independent Cylinder Port Regulation Units controlled
by a single solenoid valve, cylinder port “B” is the
normally open cylinder port. The solenoid is energized to
open cylinder port “A”. On double solenoid operated
valves, energizing solenoid “B” opens cylinder port “A”
and energizing solenoid “A” opens cylinder port “B”
Valve must be converted to external pilot supply.
Features
Regulated pressure output from the valve is adjusted by
knob on the manually set model or by air pressure signal
applied to the regulator pilot port on the remotely set
model.
Furnished with pressure gauge as standard.
The regulator controlling pressure to port “A” is mounted
on the end opposite the electrical junction box (Assembly
“A”). Regulated pressure from cylinder port “B” is
controlled by the regulator installed over the electrical
junction box (Assembly “B”).
Pressure Range Options
Maximum Supply Pressure .................................. 140 psi
Output Pressure Range..................................... 1 - 30 psi
1 - 60 psi
2 - 125 psi
Operating Temperature Range
32°F (0°C) to 175°F (79°C)
How To Order
1. Select type of adjustment
2. Select pressure range for each
cylinder port
Example:
Manual adjusted.
5-60 psi range for cylinder port “A”
and 10-125 psi for cylinder port “B”
Model No. L554 06 305C
NOTE: When using single or independent port
sandwich regulators, be aware that:
1. Cylinder port outlets are reversed.
2. 3-Position, cylinder ports open to exhaust
and cylinder ports open to inlet functions are
reversed. To produce a cylinder ports open to
exhaust function, order valve with cylinder
ports open to inlet. To produce a cylinder
ports open to inlet function, order valve with
cylinder ports open to exhaust.
Graphic Symbol
Independently Regulated Pressure
at Both “A” & “B”
BA
SUPPLY
PRESSURE
EX
Pressure
Cylinder
Model Number
Adjustment
Port “A”
Cylinder Port “B”
psi 5-30 5-60 10-125
1 -30 L554 04 304C L554 04 305C L554 04 306C
Manual 1 - 60 L554 05 304C L554 05 305C L554 05 306C
2 - 125 L554 06 304C L554 06 305C L554 06 306C
Manual with
1 - 30 L554 30 330C L554 30 331C L554 30 332C
Liquid Filled 1 - 60 L554 31 330C L554 31 331C L554 31 332C
Gauges
2 - 125 L554 32 330C L554 32 331C L554 32 332C
Remote 0 - 140 L554 14 314C
Remote with
Liquid Filled 0 - 140 L554 38 338C
Gauges
Note: Shaded units are no longer available.
Remote operator units 0-140 PSI
40
Valvair II Series
Plug-In Regulators
Catalog VAL-SK-E/USA
Independent Port Regulation
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Valvair II Series
Plug-In Regulators, 3/8" Basic Valve
ABCDEFGH JK LMN
inches 2.56 .75 1.50 2.09 11.28 2.06 1.41 .75 .34 5.00 8.44 9.09 3.19
mm 65.0 19.1 38.1 53.1 286.5 52.3 35.8 19.1 8.64 127.0 214.4 230.9 81.0
OPQRSTUVWXYZAA
inches .61 1.19 1.91 1.09 1.81 3.32 6.64 7.56
3/8", 1/2" or
.39
1" 1"
mm 15.5 30.2 48.5 27.7 46.0 84.3 168.7 192.0
3/4" NPTF
9.9
NPTF NPTF
BB CC DD EE FF GG HH JJ KK LL MM
inches
1-1/4"
3.00 1.50 1.24 7.97 4.34 .40 8.53 10.15 5.46 8.80
mm
NPTF
76.2 38.1 31.5 202.4 110.2 10.2 216.6 257.8 138.6 223.5
M
KK
GG
FF
JJ REMOTEJJ REMOTE
V
U
T
KK
L
K
N
Q
C
H
J
O
P
CC
DD
E
F
D
A
S
R
G
B
EE
BOTTOM CYL. PORTS
LOCATED HERE
W
Y DIA.
(2 HOLES)
BOTTOM CYL.
PORTS X
1/4" PIPE
PORT
Z
1/4 Pipe
1/4 Pipe
1/8 Pipe
BB
A*
B*
LL
HH END & BOTTOM
TAPPED EXT. PILOT
SUPPLY LOCATED
HERE
MM
AA
P
P
E
E
A
41
Catalog VAL-SK-E/USA
Dimensional Data
* Assembly “A” places the
regulator on the end opposite
the electrical junction box.
Assembly “B” places the
regulator over the electrical
junction box.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
7
9
13
7
16
17
14
13
1
3
2
1
32
P
E
P
E
P
E
P
E
1
3
2
7
8
9
11
6
4
5
7
8
1012
6
4
5
7
8
18
18
18
10
12
6
4
5
7
8
10
12
6 15
5
Table ‘A
Manual End Section
Common Port Regulation
psi Standard Liquid Filled
1-30 K362 301C K362 327C
1-60 K362 302C K362 328C
2-125 K362 303C K362 329C
Common Port Regulation
End Section Assemblies: See Tables ‘A’ or ‘B’
Parts: See Table ‘E’
Table ‘B’
Remote End Section
Common Port Regulation
psi Standard Liquid Filled
0-140 K362 311C K362 335C
Table ‘D’
Remote End Section
Single Independent Port
Regulation
psi Standard Liquid Filled
0-140 K362 314C K362 338C
Table ‘C’
Manual End Section
Single Independent Port
Regulation
psi Standard Liquid Filled
1-30 K362 304C K362 330C
1-60 K362 305C K362 331C
2-125 K362 306C K362 332C
Independent Port Regulation
End Section Assemblies: See Tables ‘C’ or ‘D’
Parts: See Table ‘E’
Single Port Regulation
End Section Assemblies: See Tables ‘C’ or ‘D’
Parts: See Table ‘E’
Item No. Part Number Description
9 K183 082 Gasket
10 K183 084 Gasket
11 K043 012 Function Block (P to P)
12 K043 011 Function Block (P to E)
13 H100 107 1/4-20 x 1-1/2" Lg. SHCS
14 K183 083 Gasket
15
Standard Liquid Filled Remote Reg. Assy. (w/Gauge)
K472 009C K472 018C 0-140 psi
16 K362 308
Function Plate Assy. (Incl. 7, 9, 13)
17 K362 307
Function Plate Assy. (Incl. 7, 13, 14)
18 K032 270 Body Assy. (Incl. 1, 2, 3)
Table ‘E’:
Parts
Item No. Part Number Description
1 H098 15 Screw (4)
2 H175 12 Lockwasher (4)
3 K183 077 Gasket
Standard Liquid Filled Manual Reg. Assy. (w/Gauge)
4
K472 001C K472 013C 1-30 psi
K472 002C K472 014C 1-60 psi
K472 003C K472 015C 2-125 psi
5 H175 09 #10 Lockwasher
6 H100 32 #10-32 x 1.75" Lg. SHCS
7 H175 11 1/4" Lockwasher
8 H100 69 1/4-20 x 2.25" Lg. SHCS
42
Valvair II Series
Modular Regulators
Catalog VAL-SK-E/USA
Parts Data
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
EXH
P
EXH
P
REMOTE
AIR
SIGNAL
REMOTE
AIR
SIGNAL
B A B A B A B A
11
8
9
7
43213 5 6
12
8
9
7
43256
10
1
Replacement Parts
Item No. Part Number Description
1 Diaphragm Assembly
2 Retaining Ring
3 Vee Packing
4 Poppet Assembly
5
Vee Packing
6 Backflow Retainer
7 Poppet Spring
8 .989 ID x .070 W O-Ring
9 1.301 ID x .070 W O-Ring
10 P01698 1-30 PSI Spring
P04062 1-60 PSI Spring (Blue)
P04063 2-125 PSI Spring
11 Vee Packing
12 1.674 ID x .103 W O-Ring
13 Vent Seal
Parts included in K352409 Service Kit for Manual Operated Modular
Regulators.
Parts included in K352411 Service Kit for Remote Operated Modular
Regulators.
Replacement Gauges
psi Standard Liquid Filled
0-60 3560 0400 H032 57
0-160 3560 0410 H032 58
0-300 3560 0420
Manual Adjusting
Remote Operated
Suggested Schematic of Assembled Valve,
Air Regulation and Modular Manifold Units
43
Valvair II Series
Modular Regulators
Catalog VAL-SK-E/USA
Parts & Accessories
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Full Air Operation for fastest response.
“Direct Pipe” Design for economy and
performance.
Solenoids Interchange between all styles of
direct pipe ported valves.
Variety of Operators Available;
Direct Conduit, (JIC) Junction Box, NEMA 4,
Hazardous Duty, (UL, CSA), and remote
air pilot.
Locking Manual Overrides Standard.
Non-locking overrides optional.
Indicator Lights Standard on 120VAC and
24VDC models.
Encapsulated Coil designed for low-power
consumption and maximum life.
Field Convertible to External Pilot Supply for
vacuum or other services.
“Oversized” Flow Areas.
Synthetic Rubber O-Ring Seals are specially
compounded for minimum compression and
friction for superior wear and abrasion
resistance.
Precision Ground Spool “floats” on O-ring
seals. Closed center cross-over design
saves air.
Energized
Pressure Exhaust
Pressure Exhaust
De-Energized
44
Speed King SK-200 & Valvair II Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Basic Valve Features
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Lubricated Service
2-Position - 1/4" Basic Size
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L485 2 910253
Lubricated or Non-Lubricated Service
2-Position - 3/8" & 1" Basic Size
Valvair II
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L705 3 910253L
45
Speed King SK-200 Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
46 Double
48 Single
Size
2 1/4" NPT Inlet
& Cyl. 3/8"
NPT Exh.
3 3/8" NPT Inlet,
Cyl. & Exh.
Operator
4 Remote
5 Solenoid
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box & Non-Locking Override
6 Solenoid w/Jct. Box & Locking Override
7 Solenoid w/Jct. Box & Light
(120VAC, 24VDC)
8 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Non-Locking Override
9 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Locking Override
Lead Length
Blank 19"
(Standard)
L 72"
(Optional)
Duty Cycle
2 Standard Service
Solenoid or Remote
4 Continuous Service
Solenoid
Enclosure “Class”
10 Standard (NEMA 1 & 12)
or Remote
60 Hazardous Duty
(NEMA 7 & 9) *
80 NEMA 4
Use with operator options
1 & 3 only.
* Voltage 49 / 53 only.
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Type
68 Double
70 Single
Operator
4 Remote
5 Solenoid
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box & Non-Locking Override
6 Solenoid w/Jct. Box & Locking Override
7 Solenoid w/Jct. Box & Light (120VAC, 24VDC)
8 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Non-Locking Override
9 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Locking Override
Size
3 3/8" NPT Inlet &
Cyl. 1/2" NPT Exh.
4 1/2" NPT Inlet, Cyl.
& Exh.
7 3/4" NPT Inlet &
Cyl. 1" NPT Exh.
8 1" NPT Inlet & Cyl.
1-1/4" NPT Exh.
9 1-1/4" NPT Inlet
Cyl. & Exh. *
* Not available operator
option 4 - Remote Pilot.
Lead Length
Blank 19"
(Standard)
L 72"
(Optional)
Duty Cycle
2 Standard Service
Solenoid or Remote
4 Continuous Service
Solenoid
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Enclosure “Class”
10 Standard (NEMA 1 & 12)
or Remote
60 Hazardous Duty
(NEMA 7 & 9) *
80 NEMA 4 **
Use with operator options
1 & 3 only.
* Voltage 49 / 53 only.
** Voltage 53 only
Note: Shaded options have been discontinued. Refer to back
of Catalog for Cross Reference Information.
Note: Shaded options have been discontinued. Refer to back
of Catalog for Cross Reference Information.
(Revised 04/19/06)
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Lubricated Service
2-Position
1/2" Basic Size
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L645 5 910253
46
Speed King SK-200 Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
61 Double
64 Single
Enclosure “Class”
10 Standard (NEMA 1 & 12)
or Remote
60 Hazardous Duty
(NEMA 7 & 9)
80 NEMA 4
Use with operator options
1 & 3 only.
Duty Cycle
2 Standard Service Solenoid
or Remote
4 Continuous Service
Solenoid
Lead Length
Blank 19" (Standard)
L 72" (Optional)
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box & Non-Locking Override
6 Solenoid w/Jct. Box & Locking Override
7 Solenoid w/Jct. Box & Light
(120VAC, 24VDC)
8 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Non-Locking Override
9 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Locking Override
Operator
4 Remote
5 Solenoid
Size
5 1/2" NPT Inlet & Cyl.
3/4" NPT Exh.
6 3/4" NPT Inlet, Cyl.
& Exh.
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Note: Shaded options have been
discontinued. Refer to back of Catalog
for Cross Reference Information.
(Revised 04/19/06)
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Lubricated Service
3-Position
1/4" Basic Size
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L475 2 921153
47
Speed King SK-200 Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
47 Double
Operator Options
1 Solenoid (Basic) or
Remote
2 Solenoid w/Non-Locking
Override
3 Solenoid w/Locking
Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box &
Non-Locking Override
6 Solenoid w/Jct. Box &
Locking Override
7 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
8 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Locking Override
Operator
4 Remote
5 Solenoid
Size
2 1/4" NPT Inlet & Cyl.
3/8" NPT Exh.
3 3/8" NPT Inlet, Cyl.
& Exh.
Duty Cycle
1 Standard Service
Solenoid or Remote
5 Continuous Service
Solenoid
Lead Length
Blank 19" (Standard)
L 72" (Optional)
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Enclosure “Class”
All Ports Blocked in Neutral
21 Standard (NEMA 1 & 12) or Remote
71 Hazardous Duty (NEMA 7 & 9)
91 NEMA 4
Cyl. Ports Open to Exh. in Neutral
22 Standard (NEMA 1 & 12) or Remote
72 Hazardous Duty (NEMA 7 & 9)
92 NEMA 4
Cyl. Ports Open to Inlet in Neutral
23 Standard (NEMA 1 & 12) or Remote
73 Hazardous Duty (NEMA 7 & 9)
93 NEMA 4
Use with operator options 1 & 3 only.
Note: Shaded options have been
discontinued. Refer to back of Catalog
for Cross Reference Information.
(Revised 04/19/06)
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Valvair II
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L695 3 921153
Lubricated or Non-Lubricated Service
3-Position
3/8" & 1" Basic Size
48
Speed King SK-200 & Valvair II Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
69 Double
Operator
4 Remote
5 Solenoid
Operator Options
1 Solenoid (Basic) or
Remote
2 Solenoid w/Non-Locking
Override
3 Solenoid w/Locking
Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box &
Non-Locking Override
6 Solenoid w/Jct. Box &
Locking Override
7 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
8 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
1 Standard Service
Solenoid or Remote
5 Continuous Service
Solenoid
Lead Length
Blank 19" (Standard)
L 72" (Optional)
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Enclosure “Class”
All Ports Blocked in Neutral
21 Standard (NEMA 1 & 12) or Remote
71 Hazardous Duty (NEMA 7 & 9) *
91 NEMA 4 **
Cyl. Ports Open to Exh. in Neutral
22 Standard (NEMA 1 & 12) or Remote
72 Hazardous Duty (NEMA 7 & 9) *
92 NEMA 4 **
Cyl. Ports Open to Inlet in Neutral
23 Standard (NEMA 1 & 12) or Remote
73 Hazardous Duty (NEMA 7 & 9) *
93 NEMA 4 **
Use with operator options 1 & 3 only.
* Voltage 49 / 53 only.
** Voltage 53 only.
Size
3 3/8" NPT Inlet & Cyl.
1/2" NPT Exh.
4 1/2" NPT Inlet, Cyl,
& Exh.
7 3/4" NPT Inlet & Cyl.
1" Exh.
8 1" NPT Inlet & Cyl.
1-1/4" NPT Exh.
9 1-1/4" NPT Inlet Cyl.
& Exh.*
*
Not available with operator
option 4 - Remote Pilot
Note: Shaded options have been
discontinued. Refer to back of Catalog
for Cross Reference Information.
(Revised 04/19/06)
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Speed King, SK-200
Valve Model Number System
Basic Operator Enclosure Duty Voltage & Lead
Series Type Operator Size Options “Class” Cycle Frequency Length
L625 5 921153
Lubricated Service
3-Position
1/2" Basic Size
49
Speed King SK-200 Series
“Direct Pipe Ported” Style Valves
Catalog VAL-SK-E/USA
Model Number Index
Type
62 Double
Operator Options
1 Solenoid (Basic) or
Remote
2 Solenoid w/Non-Locking
Override
3 Solenoid w/Locking
Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box &
Non-Locking Override
6 Solenoid w/Jct. Box &
Locking Override
7 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
8 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Non-Locking Override
9 Solenoid w/Jct. Box &
Light (120VAC, 24VDC)
& Locking Override
Duty Cycle
1 Standard Service
Solenoid or Remote
5 Continuous Service
Solenoid
Lead Length
Blank 19" (Standard)
L 72" (Optional)
Enclosure “Class”
All Ports Blocked in Neutral
21 Standard (NEMA 1 & 12) or Remote
71 Hazardous Duty (NEMA 7 & 9)
91 NEMA 4
Cyl. Ports Open to Exh. in Neutral
22 Standard (NEMA 1 & 12) or Remote
72 Hazardous Duty (NEMA 7 & 9)
92 NEMA 4
Cyl. Ports Open to Inlet in Neutral
23 Standard (NEMA 1 & 12) or Remote
73 Hazardous Duty (NEMA 7 & 9)
93 NEMA 4
Use with operator options 1, 2 & 3 only.
Operator
4 Remote
5 Solenoid
Size
5 1/2" NPT Inlet & Cyl.
3/4" NPT Exh.
6 3/4" NPT Inlet, Cyl.
& Exh.
Voltage & Frequency
60Hz 50Hz DC
45 12
49 24
53 120 110
57 240 220
Note: Shaded options have been
discontinued. Refer to back of Catalog
for Cross Reference Information.
(Revised 04/19/06)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative flow
path usages, service, see
Optional Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
With solenoid “A” having been energized last
– Pressure
at Port P is connected to “Cylinder” Port A. “Cylinder” Port
B is connected to “Exhaust” Port E.
Energize solenoid “B”
– Pressure at Port P is connected
to “Cylinder” Port B. “Cylinder” Port A is connected to
“Exhaust” Port E.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, see
Optional Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port E.
Single Solenoid Double Solenoid
Model Selection
Valve
Voltage
Port Size (NPT) Operator
Single Solenoid Double Solenoid P, A & B Exhaust
Type
L485 29 102 53 L465 29 102 53
120V 60Hz
1/4" 3/8"
Junction
L485 39 102 53 L465 39 102 53
110V 50Hz
3/8" 3/8"
Box
L485 26 102
**
L465 26 102
**
Other
1/4" 3/8"
Junction
L485 36 102
**
L465 36 102
**
3/8" 3/8"
Box
L485 23 102
**
L465 23 102
**
Any
1/4" 3/8"
Basic
L485 33 102
**
L465 33 102
**
3/8" 3/8"
L485 23 802
**
L465 23 802
**
Any
1/4" 3/8"
NEMA 4
L485 33 802
**
L465 33 802
**
3/8" 3/8"
L485 23 602
**
L465 23 602
**
See Voltage
1/4" 3/8"
Hazardous
L485 33 602
**
L465 33 602
**
Chart
3/8" 3/8"
Duty
See page 45 for variations and (
**
) voltage codes.
- UL & CSA Approved.
Note: Shaded areas are no longer available.
1/4" & 3/8" NPT Ports, Nominal Cv = 1.8
50
Speed King SK 200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 4-Port, 2-Position
P
ASol A Sol BB
E
P
AB
E
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K493 005 Spool
*5 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
17 K152 003 Override Assy.
18 K983 001 Shock Pad
* Standard Service Kit: K352 151
* Special Service Kit: K352 351
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K18R311093 Retaining Ring
3 K453 006 Spacer
*4 O-Ring
5 K453 005 Spacer
*6 Seal
7 K232 018 Spool Assy.
*8 Seal
*11 Gasket
13 H175 12 Lockwasher
14 H100 60 Cap Screw
18 K152 003 Override Assy.
21 K983 001 Shock Pad
* Standard Service Kit: K352 150
* Special Service Kit: K352 350
(Continuous Duty)
51
Speed King SK 200 Series
L485 & L465, 1/4" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
A EXH
B
A EXH
B
IN
6.65
168.9mm
2.90
73.7mm
1.00
25.4mm
1.00
25.4mm
6.74
171.2mm
3.00
76.2mm
1.00
25.4mm
1.00
25.4mm
4.47
113.5mm
1.84
46.7mm
.27 Dia.
6.8mm
2 Holes
2.34
59.4mm
1.17
29.7mm
1.50
38.1mm
2.75
69.8mm
2.34
59.4mm
1.17
29.7mm
4.73
120.1mm
3.31
84.1mm
.81
20.6mm
4.73
120.1mm
.81
20.6mm
.33
8.4mm
3.31
84.1mm
.33
8.4mm
4721
2
6
35
8
42 3 5 18
Single Solenoid
Double Solenoid
1.82
46.2mm
1/2 Pipe
Conduit
Connection
11
14
13
18
17
8
1.50
38.1mm
1/2 Pipe
Conduit
Connection
1.50
38.1mm
2.75
69.8mm
11
10
4.47
113.5mm
1.82
46.2mm
TYP.
1.50
38.1mm
TYP.
1.84
46.7mm
33
Typ.
X
IN
.27 Dia.
6.8mm
2 Holes
Sol. A
Sol. B
See Wiring Instructions, page 85,
for units with flying leads.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see
Optional
Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
With solenoid “A” (solenoid nearest Port B on valve body)
having been energized last
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energize solenoid “B” (solenoid nearest Port A on valve
body)
– Pressure at Port P is connected to “Cylinder”
Port B. “Cylinder” Port A is connected to “Exhaust”
Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port EA.
Single Solenoid Double Solenoid
Model Selection
Valve
Voltage
Port Size (NPT)
Operator
Single Solenoid Double Solenoid P, A & B EA & EB
Type
L705 39 102 53 L685 39 102 53
120V 60Hz
3/8" 1/2"
Junction
L705 49 102 53 L685 49 102 53
110V 50Hz
1/2" 1/2"
Box
L705 36 102
**
L685 36 102
**
Other
3/8" 1/2"
Junction
L705 46 102
**
L685 46 102
**
1/2" 1/2"
Box
L705 33 102
**
L685 33 102
**
Any
3/8" 1/2"
Basic
L705 43 102
**
L685 43 102
**
1/2" 1/2"
L705 33 802
**
L685 33 802
**
Any
3/8" 1/2"
NEMA 4
L705 43 802
**
L685 43 802
**
1/2" 1/2"
L705 33 602
**
L685 33 602
**
See Voltage
3/8" 1/2"
Hazardous
L705 43 602
**
L685 43 602
**
Chart
1/2" 1/2"
Duty
See page 45 for variations and (
**
) voltage codes.
- UL & CSA Approved.
3/8" & 1/2" NPT Ports, Nominal Cv = 4.8
52
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
A B Sol ASol B
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
7.56
192.0mm
3.32
84.3mm
2.56
65.0mm
4.69
119.1mm
6 .64
168.7mm
4.69
119.1mm
2.34
54.9mm
1.33
33.8mm
1.33
33.8mm
1.66
42.2mm
TYP
.
3.32
84.3mm
1.28
32.5mm
5.35
135.9mm
3.91
99.3mm
3.25
82.6mm
1.62
41.1mm
.53
13.5mm
.94
23.9mm
.38
9.7mm
2.56
65.0mm
.90
22.9mm
1.82
46.2mm
TYP.
1.50
38.1mm
TYP.
.90
22.9mm
1.82
46.2mm
2.34
59.4mm
1.33
33.8mm
1.33
33.8mm
1.28
32.5mm
.90
22.9mm
.90
22.9mm
1/2 Pipe
Conduit
Connection
Single Solenoid
B
X
A
EA P EB
33
Typ.
5.35
135.9mm
1.50
38.1mm
3.91
99.3mm
3.25
82.6mm
1.62
41.1mm
.53
13.5mm
.94
23.9mm
.38
9.7mm
B
X
A
EA P
EB
.27 Dia.
6.8mm
2 Holes
.27 Dia.
6.8mm
2 Holes
1/2 Pipe
Conduit
Connection
Double Solenoid
Sol. B
Sol. A
23
10
11
653221184
8
9872342556
26
12
15
14
See Wiring Instructions, page 85,
for units with flying leads
Parts List
Item
Part No. Description
No.
2 H090 71 Retaining Ring
3 K463 015 Spacer
*4 O-Ring (Dynamic)
5 K453 028 Spacer
6 K463 012 End Spacer
7 K232 020 Spool Assy.
*8 Seal
*9 Seal
*12 Gasket
14 H175 12 Lockwasher
15 H100 60 Cap Screw
22 K152 003 Override Assy.
*25 O-Ring (Static)
26 K983 002 Shock Pad
* Standard Service Kit: K352 124
* Special Service Kit: K352 125
(Continuous Duty)
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 094 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
18 K152 003 Override Assy.
*21 O-Ring (Static)
23 K983 002 Shock Pad
* Standard Service Kit: K352 126
* Special Service Kit: K352 127
(Continuous Duty)
53
Valvair II Series
L705 & L685, 3/8" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Solenoid Double Solenoid
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see
Optional
Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
With solenoid “A” (solenoid nearest Port B on valve body)
having been energized last
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energize solenoid “B” (solenoid nearest Port A on valve
body)
– Pressure at Port P is connected to “Cylinder”
Port B. “Cylinder” Port A is connected to “Exhaust”
Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
is connected to “Exhaust” Port EA.
Model Selection
Valve
Voltage
Port Size (NPT)
Operator
Single Solenoid Double Solenoid P, A & B EA & EB
Type
L645 59 102 53 L615 59 102 53
120V 60Hz
1/2" 3/4"
Junction
L645 69 102 53 L615 69 102 53
110V 50Hz
3/4" 3/4"
Box
L645 56 102
**
L615 56 102
**
Other
1/2" 3/4"
Junction
L645 66 102
**
L615 66 102
**
3/4" 3/4"
Box
L645 53 102
**
L615 53 102
**
Any
1/2" 3/4"
Basic
L645 63 102
**
L615 63 102
**
3/4" 3/4"
L645 53 802
**
L615 53 802
**
Any
1/2" 3/4"
NEMA 4
L645 63 802
**
L615 63 802
**
3/4" 3/4"
L645 53 602
**
L615 53 602
**
See Voltage
1/2" 3/4"
Hazardous
L645 63 602
**
L615 63 602
**
Chart
3/4" 3/4"
Duty
See page 46 for variations and (
**
) voltage codes. - UL & CSA Approved.
Note: Shaded areas are no longer available.
1/2" & 3/4" NPT Ports, Nominal Cv = 5.5
54
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
A B Sol ASol B
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 046 Spool
*6 Seal
*8 Gasket
10 H175 12 Lockwasher
11 H100 60 Cap Screw
18 K152 003 Override Assy.
21 K983 003 Shock Pad
* Standard Service Kit: K352 153
* Special Service Kit: K352 353
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K18R311137 Retaining Ring
3 K553 011 Washer
*4 O-Ring
5 K453 008 Spacer
6 K463 001 End Spacer
7 K232 017 Spool Assy.
*8 Seal
* 9 Seal
*12 Gasket
14 H175 12 Lockwasher
15 H100 60 Cap Screw
22 K152 003 Override Assy.
25 K983 003 Shock Pad
* Standard Service Kit: K352 152
* Special Service Kit: K352 352
(Continuous Duty)
55
Speed King SK-200 Series
L645 & L615, 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1/2 Pipe
Conduit
Connection
1/2 Pipe
Conduit
Connection
Single Solenoid
B
X
A
EA P EB
33
Typ.
Double Solenoid
B
X
A
EA P EB
Sol. B
Sol. A
8.62
218.9mm
3.83
97.3mm
1.41
35.8mm
1.41
35.8mm
1.38
35.1mm
2.75
69.8mm
5.20
132.1mm
2.60
66.0mm
1.77
45.0mm
1.77
45.0mm
1.50
38.1mm
5.52
140.2mm
4.09
103.9mm
1.06
26.9mm
7.66
194.6mm
2.75
69.8mm
1.38
35.1 mm
3.83
97.3mm
1.41
35.8mm
1.41
35.8mm
.49
12.4mm
3.69
93.7mm
1.84
46.7mm
.20
5.1m
m
.35
8.9mm
5.20
132.1mm
2.60
66.0mm
1.77
45.0mm
1.77
45.0mm
.35
8.9mm
9
8
2
3
4
5
6
7
6
3
4
18
2
21
5
25
15
14
12
1.50
38.1mm
1.82
46.2mm
Typ.
5.52
140.2mm
4.09
103.9mm
1.06
26.9mm
.49
12.4mm
3.69
93.7mm
1.84
46.7mm
.20
5.1m
m
11
10
8
22
See Wiring Instructions, page 85,
for units with flying leads.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Solenoid Double Solenoid
Application
These valves may be used to actuate double acting
cylinders. A “momentary” electrical signal (exceeding
.03 seconds) applied to one of the solenoids shifts the
valve. It will remain in this position until a “momentary”
signal is applied to the other solenoid. For alternative
flow path usages, such as dual pressure service, see
Optional Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
With solenoid “A” (solenoid nearest Port B on valve
body) having been energized last
– Pressure at Port P
is connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energize solenoid “B” (solenoid nearest Port A on
valve body)
– Pressure at Port P is connected to
“Cylinder” Port B. “Cylinder” Port A is connected to
“Exhaust” Port EA.
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see
Optional Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
De-energized (normal condition)
– Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
Energized (maintained signal applied)
– Pressure at Port
P is connected to “Cylinder” Port B, “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve
Voltage
Port Size (NPT)
Type
Single Solenoid Double Solenoid P, A & B EA & EB
L705 79 102 53 L685 79 102 53 3/4" 1"
Junction
L705 89 102 53 L685 89 102 53
110V 50Hz
1" 1-1/4"
Box
L705 99 102 53 L685 99 102 53 1-1/4" 1-1/4"
L705 76 102
**
L685 76 102
**
3/4" 1"
Junction
L705 86 102
**
L685 86 102
**
Other 1" 1-1/4"
Box
L705 96 102
**
L685 96 102
**
1-1/4" 1-1/4"
L705 73 602
**
L685 73 602
**
See Voltage
3/4" 1"
Hazardous
L705 83 602
**
L685 83 602
**
Chart
1" 1-1/4"
Duty
L705 93 602
**
L685 93 602
**
1-1/4" 1-1/4"
See page 45 for variations and (
**
) voltage codes. - UL & CSA Approved.
3/4", 1" & 1-1/4" NPT Ports, Nominal Cv = 12.0
56
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
A B Sol ASol B
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 H090 09 Retaining Ring
3 K553 009 Spacer
*4 O-Ring (Dynamic)
*5 O-Ring (Static)
6 K453 009 Spacer
7 K463 005 End Spacer
8 K232 014 Spool Assy.
*9 O-Ring
*10 Seal
*13 Gasket
15 H175 12 Lockwasher
16 H100 60 Cap Screw
23 K152 003 Override Assy.
26 K983 004 Shock Pad
* Standard Service Kit: K352 128
* Special Service Kit: K352 129
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Dynamic)
*4 O-Ring (Static)
5 K453 009 Spacer
6 K343 061 Spool
*7 Seal
*9 Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
19 K152 003 Override Assy.
22 K983 004 Shock Pad
* Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
57
Valvair II Series
L705 & L685, 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1/2 Pipe
Conduit
Connection
Single Solenoid
B
X
A
EA P EB
.41 Dia.
10.4mm
2 Holes
33
Ty p.
1/2 Pipe Conduit
Connection
Double Solenoid
B
X
A
EA P EB
.41 Dia.
10.4mm
2 Holes
Sol. B
Sol. A
23
13
.20
5.1mm
2.62
66.5mm
5.25
133.4mm
6.44
163.6mm
9.50
241.3mm
7.44
189.0mm
2.19
55.6mm
2.19
55.6mm
3.44
87.4mm
1.50
38.1mm
1.82
46.2mm
1.82
46.2mm
2.19
55.6mm
3.44
87.4mm
7.44
189.0mm
2.19
55.6mm
4.25
108.0mm
2.12
53.8mm
10.46
265.7mm
4.75
120.6mm
1.62
41.1mm
1.62
41.1mm
4.75
120.6mm
1.62
41.1mm
4.25
108.0mm
6.44
163.6mm
1.50
38.1mm
4.95
125.7mm
1.50
38.1mm
.69
17.5mm
5.25
133.4mm
2.62
66.5mm
.20
5.1mm
2.12
53.8mm
1.62
41.1mm
4.95
125.7mm
.69
17.5mm
1.50
38.1mm
16
15
9
234
7
10
8
6
5
26
2
4
3
5
12
11
6
22
19
7
9
See Wiring Instructions, page 85,
for units with flying leads.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Remote Double Remote
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
Pilot “A” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
Pilot “B” pressurized last –
Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust” Port E.
When pressure to pilot is removed
– Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B Exhaust
L484 21 102 L464 21 102 1/4" 3/8"
L484 31 102 L464 31 102 3/8" 3/8"
1/4" & 3/8" NPT Ports, Nominal Cv = 1.8
58
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 4-Port, 2-Position
P
APilot A Pilot BB
E
P
BA
E
Pilot
Note: Shaded units are no longer available.
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K493 005 Spool
*5 Seal
6 K323 027 Remote Cap
7 H100 60 Cap Screw
8 H175 12 Lockwasher
*9 Gasket
10 K983 001 Shock Pad
* Standard Service Kit: K352 357
Parts List
Item
Part No. Description
No.
2 K18R311093 Retaining Ring
3 K453 006 Spacer
*4 O-Ring
5 K453 005 Spacer
*6 Seal
7 K232 018 Spool Assy.
*8 Seal
9 K323 027 Remote Cap
*10 Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
13 K983 001 Shock Pad
* Standard Service Kit: K352 363
Single Remote
IN
EXH BA
.27 Dia.
6.8mm
2 Holes
.27 Dia.
6.8mm
2 Holes
BEXH
PILOT
A
PILOT
PILOT
B
A
IN
1/4 Pipe
1/4 Pipe
Double Remote
4.47
113.5mm
1.84
46.7mm
2.36
59.9mm
6.65
168.9mm
2.90
73.7mm
2.34
59.4mm
1.50
38.1mm
2.75
69.8mm
2.56
65.0m
m
.81
20.6mm
.33
8.4mm
2.56
65.0mm
.81
20.6mm
.33
8.4mm
1.17
29.7mm
1.00
25.4mm
1.00
25.4mm
6.74
171.2mm
3.00
76.2mm
1.00
25.4mm
1.00
25.4mm
.22
5.6mm
.22
5.6mm
2.75
69.8mm
2.34
59.4mm
1.50
38.1mm
1.17
29.7mm
3.97
100.8mm
1.61
40.9mm
4
2
6
12
11
10
713
35
8
4
210
9
3
5
8
6
9
7
59
Speed King SK-200 Series
L484 & L464, 1/4" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Remote Double Remote
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
Pilot “A” (nearest Port B on valve body) pressurized last –
Pressure at Port P is connected to “Cylinder” Port B.
“Cylinder” Port A is connected to “Exhaust” Port EA.
Pilot “B” (nearest Port A on valve body) pressurized last –
Pressure at Port P is connected to “Cylinder” Port A.
“Cylinder” Port B is connected to “Exhaust” Port EB.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
When pressure to pilot is removed
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B EA & EB
L704 31 102 L684 31 102 3/8" 1/2"
L704 41 102 L684 41 102 1/2" 1/2"
3/8" & 1/2" NPT Ports, Nominal Cv = 4.8
60
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
AB
Pilot BPilot A
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 H090 71 Retaining Ring
3 K463 015 Spacer
*4 O-Ring (Dynamic)
5 K453 028 Spacer
6 K463 012 End Spacer
7 K232 020 Spool Assy.
*8 Seal
*9 Seal
*10 O-Ring (Static)
11 K323 027 Remote Cap
*12 Gasket
13 H175 12 Lockwasher
14 H100 60 Cap Screw
15 K983 002 Shock Pad
* Standard Service Kit: K352 362
Parts List
Item
Part No. Description
No.
*2 O-Ring (Static)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 094 Spool
*6 Seal
*8 Gasket
9 K323 027 Remote Cap
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 O-Ring (Dynamic)
13 K983 002 Shock Pad
* Standard Service Kit: K352 355
7.56
192.0mm
3.32
84.3mm
2.56
65.0mm
3.18
80.8mm
6.64
80.8mm
.94
23.9mm
3.25
82.6mm
1.62
41.1mm
.53
13.5m
m
.38
9.7mm
1.28
32.5mm
4.69
119.1mm
2.34
59.4mm
1.33
33.8mm
1.33
33.8mm
.90
22.9mm
.90
22.9mm
Single Remote
B
X
A
EA
Pilot
Pilot
B
Pilot
A
PEB
.27 Dia.
6.9mm
2 Holes
3.32
84.3mm
2.56
65.0mm
1.28
32.5mm
.22
5.6mm
.22
5.6mm
4.69
119.1mm
2.34
59.4mm
1.33
33.8mm
1.33
33.8mm
.90
22.9mm
.90
22.9mm
1.98
50.3mm
1.98
50.3mm
.27 Dia.
6.9mm
2 Holes
3.05
77.5mm
.94
23.9mm
3.25
82.6mm
1.62
41.1mm
.53
13.5m
m
.38
9.7mm
B
X
A
EA P
EB
1/4 Pipe
1/4 Pipe
Double Remote
9
12
11
13
14
8
7
2
3 4 10
5
6 15
13
4
8
9
2
12
3 5
6
11
10
61
Valvair II Series
L704 & L684, 3/8" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to activate double acting
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
For alternate flow path usages, see
Optional
Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
Pilot “A” (nearest Port B on valve body) pressurized last
Pressure at Port P is connected to “Cylinder” Port B.
“Cylinder” Port A is connected to “Exhaust” Port EA.
Pilot “B” (nearest Port A on valve body) pressurized last
Pressure at Port P is connected to “Cylinder” Port A.
“Cylinder” Port B is connected to “Exhaust” Port EB.
Single Remote Double Remote
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust” Port
EB.
When pressure to pilot is removed
– Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B EA & EB
L644 51 102 L614 51 102 1/2" 3/4"
L644 61 102 L614 61 102 3/4" 3/4"
1/2" & 3/4" NPT Ports, Nominal Cv = 5.2
62
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
AB
Pilot BPilot A
EA EB
P
AB
EA EB
Note: Shaded units are no longer available.
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 046 Spool
*6 Seal
*8 Gasket
9 K323 027 Remote Cap
10 H100 60 Cap Screw
11 H175 12 Lockwasher
13 K983 003 Shock Pad
* Standard Service Kit: K352 358
Parts List
Item
Part No. Description
No.
2 K18R311137 Retaining Ring
3 K553 011 Washer
*4 O-Ring
5 K453 008 Spacer
6 K463 001 End Spacer
7 K232 017 Spool Assy.
*8 Seal
* 9 Seal
*12 Gasket
13 H323 027 Remote Cap
14 H175 12 Lockwasher
15 H100 60 Cap Screw
16 K983 003 Shock Pad
* Standard Service Kit: K352 361
Single Remote
B
X
A
EA P EB
Double Remote
B
X
A
EA P EB
1/4 Pipe
1/4 Pipe
8.62
218.9mm
2.75
69.8mm
1.38
35.1mm
1.77
45.0mm
5.20
132.1mm
2.60
66.0mm
.35
8.9mm
.20
5.1mm
3.22
81.8mm
1.06
26.9mm
.49
12.4mm
3.69
93.7mm
1.84
46.7mm
.20
5.1mm
3.22
81.8mm
1.06
26.9mm
.49
12.4mm
3.69
93.7mm
1.84
46.7mm
1.77
45.0mm
3.83
97.3mm
1.41
35.8mm
1.41
35.8mm
7.66
194.6mm
2.75
69.8mm
1.38
35.1mm
.22
5.6mm
.22
5.6mm
1.77
45.0mm
5.20
132.1mm
2.60
66.0mm
.35
8.9mm
1.77
45.0mm
3.83
97.3mm
1.92
48.8mm
3.83
97.3mm
1.41
35.8mm
1.41
35.8mm
8
9
6
3
13
2
4
5
12
9 8 23745 6
16
13
14
15
11
10
63
Speed King SK-200 Series
L644 & L614, 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Single Remote Double Remote
Application
These valves may be used to activate double acting
cylinders. Normally open signals applied to the pilot caps
are alternately bled off to actuate the valve. For alternate
flow path usages, see
Optional Functions
page.
Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
Pilot “A” (nearest Port B on valve body) pressurized last
Pressure at Port P is connected to “Cylinder” Port B.
“Cylinder” Port A is connected to “Exhaust” Port EA.
Pilot “B” (nearest Port A on valve body) pressurized last
Pressure at Port P is connected to “Cylinder” Port A.
“Cylinder” Port B is connected to “Exhaust” Port EB.
Application
These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see
Optional
Functions
page.
Mounting
Valve may be mounted in any position.
Operation: Pressure Service
Pressure to pilot cap
– Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
When pressure to pilot is removed
– Pressure at Port
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B EA & EB
L704 71 102 L684 71 102 3/4" 1"
L704 81 102 L684 81 102 1" 1-1/4"
L704 91 102 L684 91 102 1-1/4" 1-1/4"
3/4" Thru 1-1/4" NPT Ports, Nominal Cv = 12.0
64
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
4-Way, 5-Port, 2-Position
P
AB
Pilot BPilot A
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
2 H090 09 Retaining Ring
3 K553 009 Spacer
*4 O-Ring (Dynamic)
*5 O-Ring (Static)
6 K453 009 Spacer
7 K463 005 End Spacer
8 K232 014 Spool Assy.
*9 Seal
*10 O-Ring
*12 Gasket
13 K323 027 Remote Cap
14 H175 12 Lockwasher
15 H100 60 Cap Screw
16 K983 004 Shock Pad
* Standard Service Kit: K352 359
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Static)
*4 O-Ring (Dynamic)
5 K453 009 Spacer
6 K343 061 Spool
*7 Seal
*9 Gasket
10 K323 027 Remote Cap
11 H175 12 Lockwasher
12 H100 60 Cap Screw
13 K983 004 Shock Pad
* Standard Service Kit: K352 360
Single Remote
B
X
A
EA P EB
Pilot
Double Remote
B
X
A
EA
Pilot
B
Pilot
A
PEB
1/4 Pipe
1/4 Pipe
10.46
265.9mm
4.75
120.6mm
1.62
41.1mm
7.44
189.0mm
4.25
108.0mm
5.25
133.4mm
.20
5.1mm
.69
17.9mm
1.50
138.1mm
4.09
103.9mm
2.12
53.8mm
3.44
87.4mm
2.19
55.6mm
2.19
55.6mm
1.62
41.1mm
9.50
241.3mm
4.75
120.6mm
1.62
41.1mm
7.44
189.0mm
4.25
108.0mm
2.12
53.8mm
3.44
87.4mm
2.19
55.6mm
2.19
55.6mm
1.62
41.1mm
12
13
15
14
10
2
3
4
7
9
86
5
16
9
10
13
23 4
5
6
7
5.25
133.4mm
.20
5.1mm
.69
17.9mm
1.50
138.1mm
4.09
103.9mm
12
11
65
Valvair II Series
L704 & L684, 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1/4" Basic, Nominal Cv = 1.7 1/2" Basic, Nominal Cv = 5.2
Application
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement is
desired. A “momentary” (exceeding .03 seconds) or
maintained electrical signal applied to one of the
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed.
Valve may be applied for alternate service. For alternate
flow path usages, see
Optional Functions
page.
Operation: Pressure Service
Neutral “Class 21”
Both solenoids de-energized (Normal Condition)
All ports blocked.
Neutral “Class 22” (L625 Only)
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to “Exhaust” Port E (EA),
“Cylinder” Port B is open to “Exhaust” Port E (EB),
“Pressure” Port P is blocked.
Neutral “Class 23”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to Pressure Port P, “Cylinder”
Port B is open to Pressure Port P. Both “Exhaust”
Port(s) E (EA and EB) are blocked.
Activated Operation
With solenoid “A” energized
– Pressure at Port P flows to
“Cylinder” Port A, “Cylinder” Port B is connected to
“Exhaust” Port E (EB).
With solenoid “B” energized
– Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E (EA).
1/4" Basic 1/2" Basic
Model Selection (Neutral “Class 21” Shown)
Valve
Voltage
Port Size (NPT)
Operator
1/4" Basic Size 1/2" Basic Size P, A & B Exhaust
Type
L475 29 211 53 1/4" 3/8"
L475 39 211 53 120V 60Hz 3/8" 3/8" Junction
L625 59 211 53 110V 50Hz 1/2" 3/4" Box
L625 69 211 53 3/4" 3/4"
L475 26 211
**
1/4" 3/8"
L475 36 211
**
Other
3/8" 3/8" Junction
L625 56 211
**
1/2" 3/4" Box
L625 66 211
**
3/4" 3/4"
See page 47 & 49 for variations in class of neutral configuration and (
**
) voltage codes.
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4" Thru 3/4" NPT Ports
66
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
Solenoid Operated
P
AB
AB
AB
E
P
E
P
E
P
ASol B Sol A
Sol B Sol A
Sol B Sol A
B
EA EB
P
A
B
EA EB
P
AB
EA EB
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K343 020 Spool
(All Ports Blocked)
4 K343 073 Spool (Cyl. Ports
Open to Exhaust)
4 K343 021 Spool (Cyl. Ports
Open to Inlet)
5 K313 009 Piston (Long)
6 K313 010 Piston (Short)
*7 Seal
*8 Seal
*9 Seal
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
24 K152 003 Override Assy.
* Standard Service Kit: K352 151
* Special Service Kit: K352 351
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 045 Spool
(All Ports Blocked)
5 K343 067 Spool (Cyl. Ports
Open to Inlet)
5 K343 068 Spool (Cyl. Ports
Open to Exhaust)
*6 Seal
*8 Seal
9 K313 017 Piston
*10 Seal
*14 Gasket
16 H175 12 Lockwasher
17 H100 60 Cap Screw
24 K152 003 Override Assy.
28 K983 003 Shock Pad
* Standard Service Kit: K352 153
* Special Service Kit: K352 353
(Continuous Duty)
67
Speed King SK-200 Series
L475 & L625, 1/4" & 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1/2 Pipe
Conduit
Connection
B
X
A
EA P EB
5.52
140.2mm
5.20
132.1mm
1.77
45.0mm
1.77
45.0mm
.35
8.9mm
2.60
66.0mm
1.38
35.1mm
2.75
69.8mm
11.11
282.2mm
5.56
141.2mm
1.41
35.8mm
1.41
35.8mm
3.69
93.7mm
1.84
46.7mm
.20
5.1mm
4.09
103.9mm
1.06
26.9mm
.49
12.4mm
Sol. A
Sol. B
Sol. A
Sol. B
4.73
120.1mm
3.31
84.1mm
.81
20.6mm
.33
8.4mm
6234 5
1/2" Basic
8109 28
1/2 Pipe
Conduit
Connection
24
A
BEXH
IN
9.43
239.5mm
4.34
110.2mm
1.00
25.4mm
1.00
25.4mm
1.84
46.7mm
4.47
113.5mm
.27 Dia.
6.8mm
2 Holes
2.75
69.8mm
1.50
38.1mm
2.34
59.4mm
1.17
29.7mm
1/4" Basic
4
2 3
5
6
8
9
79
14
24
18
17
15
18
17
See Wiring Instructions, page 85,
for units with flying leads.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
3/8" Basic, Nominal Cv = 4.5 1" Basic, Nominal Cv = 12.0
Application
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement
is desired. A “momentary” (exceeding .03 seconds) or
maintained electrical signal applied to one of the solenoids
shifts the valve, the valve returns to the “neutral” condition
when the electrical signal is removed. Valve may be
applied for alternate service. For alternate flow path usages,
see
Optional Functions
page.
Operation: Pressure Service
Neutral “Class 21”
Both solenoids de-energized (Normal Condition)
All ports blocked.
Neutral “Class 22”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to “Exhaust” Port EA, “Cylinder”
Port B is open to “Exhaust” Port EB, “Pressure”
Port P is blocked.
Neutral “Class 23”
Both solenoids de-energized (Normal Condition)
“Cylinder” Port A is open to Pressure Port P, “Cylinder”
Port B is open to Pressure Port P. Both “Exhaust”
Ports EA and EB are blocked.
Activated Operation
With solenoid “A” (solenoid nearest Port B on valve body)
energized
– Pressure at Port P is connected to “Cylinder”
Port A, “Cylinder” Port B is connected to “Exhaust”
Port EB.
With solenoid “B” (solenoid nearest Port A on valve body)
energized
– Pressure at Port P is connected to “Cylinder”
Port B, “Cylinder” Port A is connected to “Exhaust”
Port EA.
Model Selection (Neutral “Class 21” Shown)
Valve
Voltage
Port Size (NPT)
Type
3/8" Basic Size 1" Basic Size P, A & B EA & EB
L695 39 211 53 3/8" 1/2"
L695 49 211 53 120V 60Hz 1/2" 1/2" Junction
L695 79 211 53 110V 50Hz 3/4" 1" Box
L695 89 211 53 1" 1-1/4"
L695 99 211 53 1-1/4" 1-1/4"
L695 36 211
**
3/8" 1/2"
L695 46 211
**
1/2" 1/2"
L695 76 211
**
Other 3/4" 1" Basic
L695 86 211
**
1" 1-1/4"
L695 96 211
**
1-1/4" 1-1/4"
See page 48 for variations in class of neutral configuration and (
**
) voltage codes.
4-Way, 5-Port, 3-Position - 3/8" Thru 1-1/4" NPT Ports
68
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
Solenoid Operated
P
ASol B Sol A
Sol B Sol A
Sol B Sol A
B
EA EB
P
A
B
EA EB
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 124 Spool
(All Ports Blocked)
5 K343 126 Spool (Cyl. Ports
Open to Inlet)
5 K343 125 Spool (Cyl. Ports
Open to Exhaust)
*6 Seal
*8 Seal
9 K313 049 Piston
*10 Seal
*14 Gasket
16 H175 12 Lockwasher
17 H100 60 Cap Screw
24 K152 003 Override Assy.
*27 O-Ring (Static)
29 K983 002 Shock Pad
* Standard Service Kit: K352 126
* Special Service Kit: K352 127
(Continuous Duty)
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Static)
*4 O-Ring (Dynamic)
5 K453 009 Spacer
6 K343 060 Spool
(All Ports Blocked)
6 K343 070 Spool (Cyl. Ports
Open to Exhaust)
6 K343 069 Spool (Cyl. Ports
Open to Inlet)
*7 Seal
*9 Seal
10 K313 023 Piston
*11 Seal
*15 Gasket
17 H175 12 Lockwasher
18 H100 60 Cap Screw
25 K152 003 Override Assy.
29 K983 004 Shock Pad
* Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
69
Valvair II Series
L695, 3/8" & 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
1.50
38.1mm
Typ.
1.82
46.2mm
Typ.
1.50
38.1mm
Typ.
33 Typ.
B
X
A
EA P
EB
3/8" BASIC
1" BASIC
Sol. B
Sol. A
1/2 Pipe
Conduit
Connection
B
X
A
EA P EB
.41 Dia
10.4mm.
2 Holes
Sol. B
Sol. A
4.69
119.1mm
9.64
244.8mm
4.82
122.4mm
2.34
59.4mm
1.33
33.8mm
3.25
82.6mm
13.63
346.2mm
6.81
173.0mm
4.25
108.0mm
2.12
53.8mm
2.19
55.6mm
2.19
55.6mm
3.44
87.4mm
7.44
189.0mm
6.44
163.6mm
1.50
38.1mm
.69
17.5mm
5.25
133.4mm
1.62
41.1mm
1.62
41.1mm
1.62
41.1mm
.53
13.5mm
.38
9.7mm
.94
23.9mm
3.91
99.3mm
5.35
135.9mm
.90
22.9mm
.90
22.9mm
1.28
32.5mm
2.56
65.0mm
1.66
42.2mm
Ty p.
1.33
33.8mm
1/2 Pipe
Conduit
Connection
.27 DIA.
6.9mm
2 Holes
24
14
1716
2729 10 9 8 5 3 4 6
2
529
25
72 436 10 911
15
18 17
See Wiring Instructions, page 85,
for units with flying leads.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1/4" Basic, Nominal Cv = 1.7
Application
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement
is desired. A normally open pilot signal to both pilot caps
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate service. For alternate
flow path usages, see Optional Functions page.
Operation: Pressure Service
Neutral “Class 21”
Normally open pilot signals to both pilot caps
All ports blocked.
Neutral “Class 22”
Normally open pilot signals to both pilot caps – “Cylinder”
Port A is connected to “Exhaust” Port E (EA) and
“Cylinder” Port B is connected to “Exhaust” Port E (EB).
Pressure at Port P is blocked.
Neutral “Class 23”
Normally open pilot signals to both pilot caps – “Cylinder”
Port A & B are connected to Port P. “Exhaust” Port(s) E
(EA and EB) are blocked.
Activated Operation
When Pilot “A” is exhausted – Pressure at Port P is
connected to “Cylinder” Port A. “Exhaust” Port E (EB) is
connected to “Cylinder” Port B.
When Pilot “B” is exhausted – Pressure at Port P is
connected to “Cylinder” Port B, “Exhaust” Port E (EA) is
connected to “Cylinder” Port A.
1/2" Basic, Nominal Cv = 5.2
1/4" Basic 1/2" Basic
Model Selection (Neutral “Class 21” Shown)
Valve Port Size (NPT)
P, A & B Exhaust
L474 21 211 1/4" 3/8"
L474 31 211 3/8" 3/8"
L624 51 211 1/2" 3/4"
L624 61 211 3/4" 3/4"
See page 47 & 49 for variations on ordering other neutral class configurations.
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position
70
Speed King SK-200 Series
Lubricated Service
Catalog VAL-SK-E/USA
Remote Air Pilot Operated
P
A B
EA EB
Pilot B Pilot A
Pilot B Pilot A
Pilot B Pilot A
P
A B
EBEA
P
A B
EA EB
Pilot A
Pilot A
Pilot A
Pilot B
Pilot B
Pilot B
P
A B
A B
A B
E
P
E
P
E
Note: Shaded units are no longer available.
(Revised 01-20-14)
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring
3 K453 005 Spacer
4 K343 020 Spool
(All Ports Blocked)
4 K343 021 Spool (Cyl. Ports
Open to Exhaust)
4 K343 073 Spool (Cyl. Ports
Open to Inlet)
5 K313 009 Piston (Long)
6 K313 010 Piston (Short)
*7 Seal
*8 Seal
*9 Seal
*10 Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
13 K323 027 Remote Cap
* Standard Service Kit: K352 357
Parts List
Item
Part No. Description
No.
2 K463 001 End Spacer
*3 O-Ring
4 K453 008 Spacer
5 K343 045 Spool
(All Ports Blocked)
5 K343 057 Spool (Cyl. Ports
Open to Inlet)
5 K343 068 Spool (Cyl. Ports
Open to Exhaust)
*6 Seal
7 K313 017 Piston
*8 Gasket
9 K323 027 Remote Cap
10 H100 60 Cap Screw
11 H175 12 Lockwasher
*12 Seal
*13 Seal
14 K983 003 Shock Pad
* Standard Service Kit: K352 358
1/2" Basic
1/4" Basic
B
X
A
EA P EB
CYL A
IN
EXH
PILOT
A
PILOT
B
PILOT
B
PILOT
A
CYL B
9.43
239.5mm
4.34
110.2mm
1.00
25.4mm
1.00
25.4mm
4.47
113.5mm
1.84
46.7mm
3.97
100.8mm
1.61
40.9mm
.27 Dia.
6.8mm
2 Holes
4
26 3
58 979
.22
5.6mm
.22
5.6mm
11.11
282.2mm
5.56
141.2mm
3.83
97.3mm
1.77
45.0mm
1.41
35.8mm
1.41
35.8mm
5.20
132.1mm
.35
8.9mm
.1.77
8.9mm
2.75
69.8mm
1.38
35.1mm
3.22
81.8mm
1.06
26.9mm
3.69
93.7mm
1.84
46.7mm
.20
5.1mm
.49
12.4mm
1/4 Pipe
1/4 Pipe
10
11
2.56
65.0mm
2.34
59.4mm
1.17
29.7 mm
.81
20.6mm
2.75
69.8mm
1.50
38.1mm
.33
8.4mm
.22
5.6mm
.22
5.6mm
12
11
8
9
3
26 12 136
4
5 7 14
10
13
71
Speed King SK-200 Series
L474 & L624, 1/4" & 1/2" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Application
These valves may be used to activate double acting
cylinders when “inching” or incremental rod movement is
desired. A normally open pilot signal to both pilot caps
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate services.
For alternate flow path usages, see
Optional
Functions
page.
3/8" Basic, Nominal Cv = 4.5 1-1/4" Basic, Nominal Cv = 12.0
Model Selection (Neutral “Class 21” Shown)
Valve
Port Size (NPT)
P, A & B EA & EB
L694 31 211 3/8" 1/2"
L694 41 211 1/2" 1/2"
L694 71 211 3/4" 1"
L694 81 211 1" 1-1/4"
L694 91 211 1-1/4" 1-1/4"
See page 48 for ordering other neutral configurations.
Operation: Pressure Service
Neutral “Class 21”
Normally open pilot signals to both pilot caps
All ports blocked.
Neutral “Class 22”
Normally open pilot signals to both pilot caps
“Cylinder” Port A is connected to “Exhaust” Port EA
and “Cylinder” Port B is connected to “Exhaust” Port EB.
Pressure at Port P is blocked.
Neutral “Class 23”
Normally open pilot signals to both pilot caps
“Cylinder” Ports A & B are connected to Port P.
“Exhaust” Ports EA & EB are blocked.
Activated Operation
When Pilot “A” (nearest Port B on valve body) is
exhausted
– Pressure at Port P is connected to “Cylinder”
Port A. “Exhaust” Port EB is connected to “Cylinder”
Port B.
When Pilot “B” (nearest Port A on valve body) is
exhausted
– Pressure at Port P is connected to “Cylinder”
Port B. “Exhaust” Port EA is connected to “Cylinder”
Port A.
4-Way, 5-Port, 3-Position - 3/8" Thru 1-1/4" NPT Ports
72
Valvair II Series
Lubricated or Non-Lubricated Service
Catalog VAL-SK-E/USA
Remote Air Pilot Operated
P
AB
EA EB
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
Pilot B
(Normally
Open)
Pilot A
(Normally
Open)
P
AB
EBEA
P
AB
EA EB
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Parts List
Item
Part No. Description
No.
*2 O-Ring (Dynamic)
3 K453 028 Spacer
4 K463 012 End Spacer
5 K343 124 Spool
(All Ports Blocked)
5 K343 126 Spool (Cyl. Ports
Open to Inlet)
5 K343 125 Spool (Cyl. Ports
Open to Exhaust)
*6 Seal
7 K313 049 Piston
*8 Gasket
9 K323 027 Remote Cap
10 H175 12 Lockwasher
11 H100 60 Cap Screw
*12 Seal
*13 Seal
*14 O-Ring (Static)
15 K983 002 Shock Pad
* Standard Service Kit: K352 355
Parts List
Item
Part No. Description
No.
2 K463 005 End Spacer
*3 O-Ring (Static)
*4 O-Ring (Dynamic)
5 K453 009 Spacer
6 K343 060 Spool
(All Ports Blocked)
6 K343 070 Spool (Cyl. Ports
Open to Exhaust)
6 K343 069 Spool (Cyl. Ports
Open to Inlet)
*7 Seal
8 K313 023 Piston
*9 Gasket
10 K323 027 Remote Cap
11 H175 12 Lockwasher
12 H100 60 Cap Screw
*13 Seal
*14 Seal
15 K983 004 Shock Pad
* Standard Service Kit: K352 360
1/4 Pipe
4.09
103.9mm
13.62
345.9mm
6.81
173.0mm
1.62
41.1mm
4.25
108.0mm
2.13
54.0mm
2.19
55.6mm
3.44
87.4mm
7.44
189.0mm
2.19
55.6mm
1.62
41.1mm
1.50
38.1mm
.69
17.5mm
.20
5.1mm
5.25
133.4mm
9
11
12
10
515 72 346 8 13 14
B
X
A
EA P
EB
3/8" Basic
1" Basic
3.25
82.6mm
1.62
41.1mm
.53
13.5mm
.38
9.7mm
.94
23.9mm
3.05
77.5mm
1.28
32.5mm
2.56
65.0mm
9.64
244.8mm
4.82
122.4mm
1.98
50.3mm
.90
22.9mm
.90
22.9mm
1.98
50.3mm
1.33
33.8mm
2.34
59.4mm
4.69
119.1mm
1.33
33.8mm
.22
5.6mm
.22
5.6mm
10
11
1415 12 7 13 5 2 3 4 6
8
9
.27 DIA.
6.86mm
2 Holes
B
X
A
EA P EB
1/4 Pipe
9
10
PILOT
A
PILOT
B
PILOT
A
PILOT
B
73
Valvair II Series
L694, 3/8" & 1" Basic Valve
Catalog VAL-SK-E/USA
Dimensional Data & Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Time Delay Modules Provide
Delay of valve action upon application of control signal,
removal of control signal or both application and
removal of control signal.
Delay Intervals from 0-6, 5-12, or 10-30 seconds...
up to several minutes with the addition of a small
external reservoir.
Repeatability within 10%, using clean filtered air.
Change of function without disassembly... with line
pressure on the valve.
Function
Time Delay Modules provide precise, consistent delay of
valve shift. They eliminate the need for electrical timers and
relays and simplify circuitry.
Delay interval is controlled by an externally adjustable
metering screw. Change of function is accomplished by
loosening two lock screws turning the slotted selector plate
to the desired function and re-tightening the lock screws.
Plug-In Kit Number Delay Interval
K705 2001 0 - 6 Second Delay
K705 2002 5 - 12 Second Delay
K705 2003 10 - 30 Second Delay
By adding a small external reservoir, delay interval can be
extended up to several minutes.
For accuracy and good repeatability, use filtered air to the
pilot and be sure all gaskets are tight.
Setting Selector for Desired Function
For Valves which are Solenoid Pilot Operated, or Valves
being controlled by normally open remote pilot, match the
pointer marked Elect with the desired function indicator
line.
For Valves which are being controlled by normally closed
pilot, match the pointer marked Air with the desired
function indicator line.
How To Order
To order Time Delay Modules, select model number for
delay interval required. Modules are furnished with gaskets,
screws, and installation instructions.
Non Plug-In
Non Plug-In Kit Number Delay Interval
K705 1001 0 - 6 Second Delay
K705 1002 5 - 12 Second Delay
K705 1003 10 - 30 Second Delay
Plug-In
74
Speed King SK-200 & Valvair II Series
Pneumatic Time Delay
Catalog VAL-SK-E/USA
Accessories
.66
17mm
1.00
25mm
2.00
51mm
.26
7mm
1.31
33mm
.58
15mm
1.25
32mm
Main Valve
Time Delay
Module
Pilot Valve Or
Remote Adapter Cap
Dia. 2 Holes
.66
17mm
1.00
25mm
2.00
51mm
.26
7mm
1.31
33mm
.58
15mm
1.25
32mm
Main Valve
Time Delay
Module
Pilot Valve Or
Remote Adapter Cap
Dia. 2 Holes
1.
2.
3.
To Main
Valve
To Pilot
Time Delay Module
1. Time Delay After Application
of Signal to Solenoid. (Elect.
Pointer)
2. Time Delay After Removal
of Signal From Solenoid.
3. Time Delay After Application
and Removal of Signal to
Solenoid.
Plug-In Non Plug-In
DISCONTINUED
DISCONTINUED
(Revised 10-23-14)
Note: Shaded units are no longer available.
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
“Blank Station” Covers
Manifold Assembly Blank Cover Kit
K142 076 K060 20007
K142 077
K142 230
K142 231 K060 20003
K142 270
K142 233 K060 20009
K142 234
K142 235
K142 236 K060 20004
K142 237
“Flush Type” Hex Drive
Pipe Plugs for Port Isolation
Part No. Size (NPTF)
K21R02012 1/8"
K21R02025 1/4"
K21R02037 3/8"
K21R02050 1/2"
K21R02075 3/4"
K21R02100 1"
H074 72 1-1/4"
H074 30 1-1/2"
Voltage Suffix Codes
Code Voltage Coil Number
** 60 Hz 50 Hz DC Plug-In Flying Lead (19") *
Replace With
40 12 3 K593 052 K593 007
42 24 6 K593 048 K593 003
43 27 24 K593 061 K593 015 K593 048 / K593 003
45 12 K593 055 K593 010
49 24
K593 060
K593 014
K593 274
51 130 48 K593 074 K593 028
53 120 110
K593 071
K593 025
K593 125
57 240 220 K593 081 K593 035
60 90 K393 020
61 120 K593 041
Notes: Shaded areas are no longer available.
Bold Face type indicated primary coil rating.
- Indicates voltages approved for solenoid operators designed for use in hazardous locations. (See page 87.)
*
- 19" Coil lead length is standard. Other lead lengths may be available, consult supplier.
‡ - Assembly includes indicator light socket, less light.
Electrical Connectors
Single or Double Solenoid Valves
Basic Valve Body Subbase/Manifold
Size Single Double 19" 72" 12'
Sol. Sol. Leads Leads Leads
1/4" H027 17 H027 26 H027 19
3/8"
1/2" H027 23 H027 22 H027 13 H027 89 H027 40
1"
Notes: Shaded units are not standard stock items.
Interchangeable
Manual Override Assemblies
for Solenoid Operators
Non-Locking Type Locking Type
K162 001 K152 003
Effective June 1, 1990 the Flush Locking Override replaced the
Extended Knob Locking Override as the Schrader Bellows standard.
The part number remains K152 003. To override valve, use a flat
head screwdriver to press in and rotate plunger 90° until plunger
locks in place. For proper valve operation, override should be in the
out position.
L **
Voltage Code
75
Speed King SK-200 & Valvair II Series
Voltage Suffix Codes
Catalog VAL-SK-E/USA
Accessories
(Revised 03-31-16)
DISCONTINUED
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
To use this chart you must know the Basic Valve Series, Quantity, and Type of Operators, or the first three characters of
the Valve Model Number.
Basic
Solenoid Operated *
Remote Pilot
Valve
Standard Service Special Service **
Operated
(Intermittent Duty) (Continuous Duty)
Size
Series
Single
Double
Single
Double
Single
Double
(Prefix) 2 & 3-Position 2 & 3-Position 2 & 3-Position
L41 K352 151 K352 351 K352 357
L42 K352 151 K352 351 K352 357
1/4"
L44 K352 150 K352 350 K352 363
L46 K352 151 K352 351 K352 357
L47 K352 151 K352 351 K352 357
L48 K352 150 K352 350 K352 363
L65 K352 126 K352 127 K352 355
L66 K352 126 K352 127 K352 355
3/8"
L67 K352 124 K352 125 K352 362
*
L68 K352 126 K352 127 K352 355
L69 K352 126 K352 127 K352 355
L70 K352 124 K352 125 K352 362
L51 K352 153 K352 353 K352 358
L52 K352 153 K352 353 K352 358
1/2"
L54 K352 152 K352 352 K352 361
L61 K352 153 K352 353 K352 358
L62 K352 153 K352 353 K352 358
L64 K352 152 K352 352 K352 361
L65 K352 130 K352 131 K352 360
L66 K352 130 K352 131 K352 360
1" L67 K352 128 K352 129 K352 359
L68 K352 130 K352 131 K352 360
L69 K352 130 K352 131 K352 360
L70 K352 128 K352 129 K352 359
Notes:
* Kits for solenoid operated valves include solenoid service kits.
** Special service (continuous duty) solenoids may be identified as having gold colored solenoid tops.
Valvair II valves are easily identified by gold colored valve end caps.
Conversion Kits: Lubricated to Non-Lubricated Operation
Basic
Operators (Solenoid or Remote Pilot)
Size
Single
Double
Double (3-Position)
(2-Position)
All Ports Blocked Cyl. to Exh. Cyl. to Inlet
3/8"
K322 012 K322 013 K322 014 K322 015 K322 016
K352 359 K352 360 K352 360
1" K092 070 K092 070 K103 103 Gold Colored
K092 071 2-Req’d End Caps 2-Req’d
( )( )
76
Speed King SK-200 & Valvair II Series
“Quick Reference Guide”
Catalog VAL-SK-E/USA
Service Kits
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
11
16
23
28
24
13
25
18
3.12
79.2mm
2.62
66.5mm
1.63
41.4mm
1.28
32.5mm
.81
20.6mm
16
20
2
7
8
21
19
2
4
7
8
1.81DIA
46.0mm
5
.69
17.9mm
.47
11.9mm
.53
13.5mm
Item No. Part Number Description
* 16 H142 01 Seal
18 K152 003 Override Assembly
19 K213005 Insert
* 20 H134 13 O-Ring
* 21 H134 73 O-Ring
* 23 H134 58 O-Ring
* 24 H134 62 O-Ring
25 K333 002 Plug
28 K183 108 Gasket
* Parts included in Service Kit. (For other voltages see page 75.)
Special Service Kit K352 366
Standard Service Kit K352 166
** Light not included with coil.
Note: Shaded units are no longer available.
Parts List
Item No. Part Number Description
2 K423 005 Top Seat (STD. Service)
K423 010 Top Seat (SPL. Service)
* 4 H142 13 Seal
* 5 K183 001 Gasket
* 7 H249 69 O-Ring
* 8 K343 002 Plunger (STD. Service)
K343 001 Plunger (SPL. Service)
11 H191 05 Light (120 AC)
H191 12 Light (24VDC)
K593 125 Coil 120V 60Hz / 110V 50 Hz,
for Indicator Light**
K593 071 Coil 120V 60Hz / 110V 50Hz
K593 081 Coil 240V 60 Hz / 220V 50 Hz
13 K593 048 Coil 6VDC / 12V 60Hz
K593 055 Coil 12VDC
K593 274 Coil 24VDC, for Indicator Light**
K593 060 Coil 24VDC
Plug-In Pilot with
Indicator Light
Replacement Pilots
Description Standard Service Special Service
Override Type Locking Non-Locking Locking Non-Locking
With Override (120VAC) K175 9035 53 K175 8035 53 K185 9025 53 K185 8025 53
With Override (Other than 120VAC) K175 3035** K175 2035** K185 3025** K185 2025**
** See voltages on page 75.
Standard Pilot Only
77
Speed King SK-200 & Valvair II Series
Plug-In Pilot
Catalog VAL-SK-E/USA
Replacement Parts
Special Service
Pilot Only
(Revised 11-03-09)
Pneumati
c
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
1.81 DIA.
46.0mm
3.05
77.5mm
1.62
41.3mm
2.62
66.5mm
1.28
32.5mm
1.47
37.3mm
2.81
71.4mm
1.81
46.0mm
.81
20.6mm
1/2 N.P.T.
Conduit
Connection
10
13
16
14
4
24
12
1.50
38.1mm
5
.69
17.5mm
.53
13.5mm
18
20
21
11
6
8
11
6
8
Parts List
Item No. Part Number Description
K593 025 Coil 120V 60Hz / 110V 50Hz
K593 035 Coil 240V 60Hz / 220V 50Hz
4 K593 003 Coil 6VDC / 12V 60Hz
K593 010 Coil 12VDC
K593 014 Coil 24VDC
K593 041 Coil 120VDC
5 H142 13 Seal
6 K423 006 Top Seat
K423 010 Top Seat (SPL. Service Pilot)
8 K343 002 Plunger (STD. Service)
K343 001 Plunger (SPL. Service)
* 10 H142 01 Seal
* 11 H249 69 O-Ring
Item No. Part Number Description
12 K272 004 Plunger Guide
13 K152 003 Override Assembly
14 K183 047 Cover Gasket
* 16 K183 001 Gasket
* 18 H134 73 O-Ring
* 20 H134 13 O-Ring
* 21 H147 01 Shock Pad
22 H191 02 120 AC Only – Indicator Light
24 K183 108 Gasket
Replacement Pilots
Description Standard Service Special Service
Override Type Locking Non-Locking Locking Non-Locking
Basic with Override K065 3035
**
K065 2035
**
K085 3025
**
K085 2025
**
JIC with Junction Box & Override K065 6035
**
K065 5035
**
K085 6025
**
K085 5025
**
JIC Pilot with Junction Box & K065 9035
**
K065 8035
**
K085 9025
**
K085 8025
**
Override & Indicator Lights (120VAC Only)
** See voltages on page 77.
Basic Pilot JIC Pilot
Special Service
Pilot Only
Coil leads are 19" long (For other voltages see page 75).
* Parts included in Service Kit.
Special Service Kit K352 366
Standard Service Kit K352 166
NOTE: Shaded units are no longer available.
78
Speed King SK-200 & Valvair II Series
NEMA 1 & 12
Catalog VAL-SK-E/USA
Replacement Parts
(Revised 08-04-11)
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
17
12
10
11
3.33
84.6mm
1.58
40.1mm
.76
19.3mm
1.62
41.1mm
2.87
72.9mm
3.34
84.8mm
1/2 NPT
Conduit
Connection
18
.43
11.4mm
.67
17.0mm
.48
12.2mm
6
7
4
5
13
7
10
4
Replacement Pilots
Description Standard Service Special Service
Hazardous Duty Pilot - UL & CSA K025 1035
**
K045 1025
**
NEMA 4 Pilot K235 1035
**
K255 1025
**
Override Type Locking Non-Locking Locking Non-Locking
Hazardous Duty with Override K025 3035
**
K025 2035
**
K045 3025
**
K045 2025
**
NEMA 4 with Override K235 3035
**
K235 2035
**
K255 3025
**
K255 2025
**
49 / 53 only ** See voltages on page 77.
Hazardous Duty NEMA 4 Pilot
Parts List
Item No. Part Number Description
* 4
K343 002 Plunger (STD. Service)
K343 001 Plunger (SPL. Service)
* 5 K142 13 Seal
* 6
H134 11 O-Ring
H134 61 O-Ring (STD. Service)
* 7 H249 69 O-Ring (SPL. Service)
10
K423 001 Top Seat
K423 002 Top Seat (SPL. Service)
K593 025 Coil 120V 60Hz / 110V 50Hz
K593 035 Coil 240V 60Hz / 220V 50Hz
11
K593 003 Coil 6VDC / 12V 60Hz
K593 010 Coil 12VDC
K593 014 Coil 24VDC
K593 041 Coil 120VDC
Item No. Part Number Description
12 K152 003 Override Assembly
* 13 H134 73 O-Ring
* 17 H137 16 Gasket (NEMA 4 Rated Pilot Only)
* 18 K183 001 Gasket
Coil leads are 19" long (For other voltages see page 75).
* Parts included in Service Kit.
Special Service Kit K352 366
Standard Service Kit K352 166
NOTE: Shaded units are no longer available.
Special Service Pilot Only
NEMA 4 Rated Pilot Only
79
Speed King SK-200 & Valvair II Series
NEMA 4, 7 & 9
Catalog VAL-SK-E/USA
Replacement Parts
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
P
ABAB
EA
P
E
AB
P
E
AB
P
E
EB
P
AB
EA
EB
P
AB
EA EB
PLUG
PLUG
AB
P
E
PLUG
PLUG
AB
P
E
PLUG
AB
P
E
PLUG
AB
P
(P1)(P2)
E
PLUG
PLUG
PLUG
PLUG
P
AB
EA
EB
PLUG
PLUG
P
AB
EA EB
PLUG
PLUG
AB
EB
PLUG
PLUG
P
(P1)
EA
(P2)
AB
P
(E)
EA
(P1)
EB
(P2)
PLUG
AB
EB
PLUG
PLUG
P
EA
X
Speed King, Valves are exceptionally versatile and may be used to perform a wide variety of functions, some of which
are illustrated here for your convenience.
Standard 4-Way
Directional Control
4-Way With Exhaust Port
Speed Control
3-Way Normally Closed
3-Way Normally Open
Pressure Selector
P1 Must Be 35-140 PSI
P2 May Be 0-250 PSI or Vacuum
2-Way Normally Closed
2-Way Normally Open
Dual Pressure 4-Way
X- External Pilot Supply 35-140 PSI
P1 & P2 May Be 0-250 PSI or Vacuum
4-Ported Valves 5-Ported Valves
80
Speed King SK-200 & Valvair II Series
Optional Functions
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
The capacity curves shown in the chart are for theoretical valve having a C
v
- 1.0 for air at standard
conditions –temperature 68°F, 36% relative humidity and 14.7 PSI absolute pressure.
To estimate the SCFM capacity of a valve, if the supply or initial pressure is known, proceed as follows:
Assuming initial pressure to 100 PSIG, select the 100 PSI initial pressure curve and follow it
upward and to the left edge of the chart. Read the flow in SCFM (in this example flow is approximately
56 SCFM). Multiply the SCFM flow obtained in the chart by the C
v
for valve and flow path desired
shown in the accompanying table.
To estimate valve size for a known required flow and initial pressure, divide the required SCFM flow by
the SCFM obtained from the flow chart. Select the required valve size from the valves listed in the table
which have a C
v
that slightly exceeds the quotient.
For example:
Assuming 200 SCFM required flow, 100 PSIG initial pressure, divide 200 SCFM by
56 SCFM (max. flow from chart). The quotient is 3.57 (200/56 = 3.57). Valves with a C
v
of 3.57 or
greater selected from the table will provide the required flow.
To estimate flow capacity at a specific “final pressure, locate the desired final pressure on the bottom
scale of the chart. Follow a vertical line upward until it intersects the initial pressure curve. Then follow a
horizontal line from that point to the left edge of the chart. Read SCFM flow. Multiply SCFM obtained in
chart by C
v
of selected valve for flow.
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
INITIAL PRESSURE IN PSIG
FINAL PRESSURE IN PSIG
FLOW IN SCFM
90
80
70
60
50
40
30
20
10
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
C
v
Method
Data at Std. Conditions
68°F Temperature
14.7 PSI Abs. Pressure
36% Relative Humidity
Q = 22.48 C
v
C
v
= Flow Coefficient
( Pc) x (P
2
)
(T
1
) x (G)
G = Specific Gravity of fluid related to air = 1 @
14.7 psia, 68°F, 36% Relative Humidity
P
2
= Downstream Pressure (psia)
Pc = Component pressure drop
Q = Flow Rate (scfm) at 14.7 psia, 68°F,
36% Relative Humidity
T
1
- Upstream Temperature °R (°R = °F + 460)
Flow Rating determined in accordance with
NFPA recommended Standard NFPA/T3.21.3-1972.
81
Speed King SK-200 & Valvair II Series
Flow Capacities
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Cylinder
Mounting
C
v
Flow Rating
Valve Type Port Size
Style
Inlet to Inlet to Cylinder “A” Cylinder “B”
(NPTF)
Cylinder “A” Cylinder “B” To Exhaust To Exhaust
1/4" Single
1/4" Subbase 1.2 1.4 1.1 1.1
1/4" Manifold 1.1 1.3 1.0 1.0
3/8" Subbase 4.8 4.8 4.5 4.8
1/2" Subbase 5.5 5.1 5.3 4.9
3/8" Single
3/4" Subbase 5.1 4.9 5.3 5.1
3/8" Manifold 4.5 4.2 4.0 4.0
1/2" Manifold 5.0 4.5 4.7 4.5
3/4" Manifold 4.8 4.4 4.9 4.5
1/2" Subbase 5.1 4.5 5.2 4.8
1/2" Single
3/4" Subbase 5.3 5.0 5.4 5.2
1/2" Manifold 4.6 4.5 4.6 4.5
3/4" Manifold 4.8 4.9 4.9 4.8
3/4" Subbase 10.1 11.0 10.4 9.9
1" Subbase 12.3 11.8 11.8 11.8
1" Single
1-1/4" Subbase 12.4 11.6 12.4 12.7
3/4" Manifold 10.7 10.7 10.9 10.9
1" Manifold 11.6 12.1 12.1 11.6
1-1/4" Manifold 12.6 12.6 12.6 11.9
1/4" Double
1/4" Subbase 1.4 1.7 1.3 1.4
1/4" Manifold 1.3 1.6 1.3 1.4
3/8" Subbase 4.5 4.4 4.5 4.0
1/2" Subbase 5.5 5.0 5.1 5.0
3/8" Double
3/4" Subbase 5.0 5.0 5.5 5.5
3/8" Manifold 4.5 4.0 4.0 4.0
1/2" Manifold 4.8 4.4 4.7 4.8
3/4" Manifold 4.9 4.4 5.1 4.6
1/2" Subbase 4.8 5.1 5.1 5.0
1/2" Double
3/4" Subbase 5.5 5.1 5.9 5.5
1/2" Manifold 4.4 4.5 4.5 4.7
3/4" Manifold 5.0 4.8 5.2 5.1
3/4" Subbase 10.9 11.1 10.3 10.3
1" Subbase 11.4 11.9 11.9 11.4
1" Double
1-1/4" Subbase 12.0 12.0 11.8 12.0
3/4" Manifold 10.7 10.2 10.9 10.9
1" Manifold 12.3 11.5 11.2 11.2
1-1/4" Manifold 12.8 11.9 11.9 11.6
1/4" Double
1/4" Subbase 1.4 1.7 1.5 1.4
3-Position 1/4" Manifold 1.3 1.7 1.5 1.4
3/8" Subbase 3.8 3.9 4.0 3.9
1/2" Subbase 4.2 4.7 5.2 5.0
3/8" Double
3/4" Subbase 4.5 4.5 4.4 4.6
3-Position 3/8" Manifold 3.7 3.8 4.2 4.1
1/2" Manifold 3.9 4.0 4.9 4.6
3/4" Manifold 4.1 3.9 4.2 4.0
82
Speed King SK-200 & Valvair II Series
Flow Capacities
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Cylinder
Mounting
C
v
Flow Rating
Valve Type Port Size
Style
Inlet to Inlet to Cylinder “A” Cylinder “B”
(NPTF)
Cylinder “A” Cylinder “B” To Exhaust To Exhaust
1/2" Subbase 4.7 4.8 4.8 4.8
1/2" Double
3/4" Subbase 5.5 4.8 5.3 5.0
3-Position 1/2" Manifold 4.2 4.2 4.4 4.8
3/4" Manifold 4.8 4.6 4.6 5.0
3/4" Subbase 10.2 10.3 9.9 10.3
1" Subbase 10.6 11.0 11.4 10.9
1" Double
1-1/4" Subbase 11.6 11.6 11.8 11.6
3-Position 3/4" Manifold 9.8 10.0 10.6 10.1
1" Manifold 10.8 11.1 11.1 10.8
1-1/4" Manifold 11.3 11.8 11.9 11.4
1/2" Subbase 4.1 4.2 5.0 4.8
1/2" Single Sol.
3/4" Subbase 4.3 4.4 5.2 5.2
Poppet 1/2" Manifold 4.2 4.8 4.4 4.6
3/4" Manifold 4.6 4.6 4.5 4.8
1/4" Single
1/4" Direct Pipe 1.8 2.2 1.8 1.9
3/8" Direct Pipe 2.0 2.2 1.9 2.0
3/8" Single
3/8" Direct Pipe 4.7 4.6 4.7 4.9
1/2" Direct Pipe 5.3 5.2 5.3 5.5
1/2" Single
1/2" Direct Pipe 5.1 5.1 5.2 5.3
3/4" Direct Pipe 5.6 5.2 5.6 5.9
3/4" Direct Pipe 10.9 10.9 11.9 11.9
1" Single
1" Direct Pipe 12.4 13.0 13.0 13.3
1-1/4" Direct Pipe 12.9 12.5 13.1 13.1
1/4" Double
1/4" Direct Pipe 1.8 1.7 1.9 1.7
3/8" Direct Pipe 1.8 1.9 1.9 2.0
3/8" Double
3/8" Direct Pipe 4.5 4.7 4.7 4.8
1/2" Direct Pipe 5.5 5.2 5.1 5.3
1/2" Double
1/2" Direct Pipe 5.2 5.0 5.1 5.5
3/4" Direct Pipe 5.7 5.5 5.7 5.8
3/4" Direct Pipe 10.9 11.4 10.9 11.4
1" Double
1" Direct Pipe 12.5 12.5 11.9 12.5
1-1/4" Direct Pipe 13.0 13.6 13.0 13.0
1/4" Double
1/4" Direct Pipe 1.7 1.6 1.9 1.8
3-Position 3/8" Direct Pipe 1.8 1.9 1.9 1.9
3/8" Double
3/8" Direct Pipe 4.1 4.1 4.2 4.1
3-Position 1/2" Direct Pipe 4.5 4.2 4.5 4.8
1/2" Double
1/2" Direct Pipe 5.0 4.7 5.2 5.5
3-Position 3/4" Direct Pipe 5.4 5.0 5.3 5.7
1" Double
3/4" Direct Pipe 10.6 11.1 10.9 10.4
3-Position
1" Direct Pipe 11.0 11.4 12.1 11.8
1-1/4" Direct Pipe 12.1 12.5 12.5 12.0
83
Speed King SK-200 & Valvair II Series
Flow Capacities
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Materials of Construction
Valve Bodies: Aluminum alloy
Valve Spool: * Aluminum alloy with special coating on
3/8" & 1" basic valves
Hard chrome plated AISI type 416
stainless steel on 1/4" & 1/2"
basic valves.
Resilient Seals: In Valve Body -
Dynamic: Polyurethane base on
3/8" & 1" basic valves*
Static/Dynamic: Nitrile base w/12% Molybdenum
Disulphide on 1/4" & 1/2"
basic valves
Other Seals: Nitrile
Shock Pads: Polyurethane
Valve Spacers: Brass
Manifolds & Subbases: Aluminum alloy
Solenoid Bodies: Plated zinc alloy
Internal Components: Corrosion resistant steel
Resilient Seals: Standard service - Nitrile
Special service (continuous duty)-
Fluorocarbon & Silicone
Other Seals: Nitrile
Coil: Class “B” epoxy encapsulated
(Class “H” also available on some models,
consult supplier)
* These materials are specially designed for valves used on
non-lubricated service.
Valve Selection
Safety factors are designed into each valve. However,
it is important that the application requirements do not
exceed the limits stated for pressure and temperature.
“Nominal C
v
” ratings are given on each ordering page.
These represent an average of performance for all
flow-paths of a given valve size. Valves should be
sized to an application using actual C
v
(Flow
Coefficient) values. See
Flow Capacities
Section for
this data.
Life Expectancy
Valves designed for non-lubricated service as well as
those designed for lubricated service will provide
millions of maintenance free cycles. Under laboratory
conditions service life exceeds 25,000,000 cycles!
Factory Pre-Lubrication
Valves are lubricated at assembly with Sunaplex 781
or equivalent. Valves specified for vacuum service are
lubricated with Dow Corning Valve Seal A.
Valves for Non-Lubricated Service
3/8" and 1" basic valve sizes are designed to operate
in applications where in-service lubrication is not
desirable. Valves are factory pre-lubed as noted
above. These valves may be used for lubricated
service as well.
Lubrication
Air Line Lubricant (compatible with Nitrile &
Polyurethane seals) must readily atomize and
be of the medium analine type. Analine point
range must be between 180° and 220°F.
Viscosity @ 100°F: 140-170 SUS.
Recommended Lubricant
If in-service lubrication is required, use F442 oil, or
equivalent. F442 is specially formulated to provide
peak performance and maximum service life for air
operated equipment.
84
Speed King SK-200 & Valvair II Series
Engineering Data
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Installation
Valves should be installed with reasonable
accessibility for service. Exercise care in keeping
piping lengths to a minimum. Piping should be free of
dirt, chips & scale. Pipe joint compound should be
used sparingly applied only to the thread, never to the
valve body. Avoid undue strain at piping joints. Protect
the valve from exposure to extreme temperatures, dirt
and moisture to maximize life.
Note: Valves equipped with locking manual overrides.
Override(s) must be in the fully extended position for
proper valve operation.
Double Solenoid/Remote Caution
Note: It is recommended that double solenoid and
double remote 2-Position valves be mounted with the
main spool in the horizontal plane.
Wiring Instructions for Base Mounted Valves
Single Solenoid:
Use wires marked “2” & “3” for connection. Units with
DC Solenoids and indicator lights are polarity
sensitive. Wire marked “3” is positive (+).
Double Solenoid:
Use wires marked “1” & “2” for Solenoid “A”. Use wires
marked “3” & “4” for Solenoid “B”. Units with DC
Solenoids and indicator lights are polarity sensitive.
Wires marked “1” and “3” are positive.
Caution: DC Solenoids are polarity sensitive.
Observe polarities indicated above.
Units with flying leads
Wires are not polarity sensitive.
Caution: DC solenoids with indicator lights and/or
arc suppression coils are polarity sensitive. Use red
wire as positive.
Listing Agencies
General Purpose Approvals
CSA - Canadian Standards Association
File Number 42024
Hazardous Duty Approvals
UL - Underwriters Laboratories, Inc.
File Number E42542
Category Y107
CSA - Canadian Standards Association
File Number 24349
See page 87 for Approved Hazardous Location Class,
Group & Division.
“Special Service” Solenoid
(Continuous Duty)
Special Service Solenoids are designed for use when
the solenoid duty cycle is greater that 70% or when
energization times are for 10 minutes or longer.
These solenoids should be used when valves are to
be held energized for hours, days or weeks… or when
extended ambient temperature operation is required.
Apply the duty cycle formula to determine if this type
of solenoid is required.
Duty Cycle Formula
Time Energized
x 100 = % Duty Cycle
Time Energized + Time Off
If Duty Cycle is 70% or greater, then Special Service
(Continuous Duty) Solenoid should be used.
Pilot Supply Conversion
Base Mounted
For field conversion to
external pilot supply,
remove two 1/8" NPTF
plugs from top of valve
body and move bottom
plug from “Y” to “Z”.
Replace 1/8" NPTF
plugs and connect pilot
pressure to the 1/4"
NPTF external pilot
supply port “X” in
subbase.
Direct Pipe Ported
For field conversion to
external pilot supply,
remove and discard 1/4"
NPTF plug in external
pilot supply port “X”.
Move stored plug “Y” to
location “Z” in bottom of
pilot supply port “X”.
Then connect pilot
pressure to port “X” in
valve body.
85
Speed King SK-200 & Valvair II Series
Engineering Data
Catalog VAL-SK-E/USA
Technical Information
X
Z
Y
YZ
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Pressure Range for Solenoid Operated Valves
Internal Pilot Supply External Pilot Supply
Media
Basic Valve Size Basic Valve Size
1/4" 3/8" 1/2" 1" 1/4" 3/8" 1/2" 1"
Air 35-140
*
PSIG N.A.
Main 0-250 PSIG
Pilot 35-140
*
PSIG
Vacuum Do Not Use N.A.
Main Within 1 Hg of Perfect
Pilot 35-140
*
PSIG
Other Consult Supplier
*
Note: 200 PSIG Solenoid Is Optional (consult supplier).
Pressure Range for
Remote Pilot Operated Valves
Media
Valve Type
Single Double & 3-Position
Air
Main 35-250 PSIG 0-250 PSIG
Pilot 35-200 PSIG 35-200 PSIG
Vacuum
Main Do Not Use Within 1" Hg of Perfect
Pilot Do Not Use 35-200 PSIG
Other Consult Supplier
Ambient Temperature Range
Standard Service Solenoid Operator
Minimum
Maximum
Intermittent Duty Continuous Duty
0°F 125°F 100°F
Special Service (Continuous Duty)
Solenoid Operator
Minimum
Maximum
Intermittent Duty Continuous Duty
0°F 125°F 125°F
As the above chart indicates, Standard Duty Solenoids
may be used on continuous duty but ambient temperature
is de-rated.
In some cases, Special Service Solenoids may be rated
for higher ambient temperatures (consult supplier).
Ambient Temperature Range
Remote Pilot Operated Valves
Remote Pilot
Minimum Maximum
0°F 200°F
Caution
If it is possible that the ambient temperature may fall
below freezing, the medium must be moisture free to
prevent internal damage and unpredictable behavior.
86
Speed King SK-200 & Valvair II Series
Engineering Data
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Hazardous Duty Solenoid Listing
Valves with solenoid operators designated for hazardous locations
are UL & CSA Approved as follows:
National Electric Code Ambient Conditions NEMA Classification
Class I Div. 1 Group C Ethyl, Ether, Etc., Gases & Vapors VII (7)
Class I Div. 1 Group D Gasoline, Etc., Gases & Vapors VII (7)
Butadiene, Etc., Liquid, Fluid or
Class I Div. 2 Group B Vapor Normally Contained, or VII (7)
Atmosphere Ventilated
Class II Div. 1 Group E Metal Dust IX (9)
Class II Div. 1 Group F Coal, Coke, Carbon Black Dust IX (9)
Class II Div. 1 Group G Flour, Starch, Grain Dust IX (9)
See Article 500 - Hazardous (Classified) Locations, National Electric Code.
Solenoid Enclosure Ratings
Type Listing Agency NEMA Rating Description
General Purpose
Plug-In CSA 1 & 12 Indoor Only
Dust Tight
General Purpose
Conduit / Flying Lead CSA 1 & 12 Indoor Only
Dust Tight
*
Conduit
UL & CSA 7 & 9
Hazardous Location
(As Specified) (See Chart Below)
*
Conduit
General Purpose
CSA 4 Indoor / Outdoor
(As Specified)
Watertight
*
See ordering information on specific valve type. (Direct Pipe Ported Valves Only.)
Voltage Code Replacement Coils & Electrical Characteristics
Voltage Code:
Final Two Digits in valve model number
L
**
Voltage Code
Voltage Code Plug-In Style Flying Leads
Electrical Characteristics
**
Voltage
Coil Number Coil Number
Watts
Inrush Holding
V/A
Amps Amps
Inrush Hold
45 12VDC K593 055 K593 010 8 .66 7.92
49 24VDC K593 060 K593 014 8 .32 7.68
53
120V/60Hz
K593 125 K593 025
9 .29 .18 31.2
110V/50Hz 7 .32 .22 23.1
57
240V/60Hz
K593 081 K593 035
13 .18 .12 41.4
220V/50Hz 9 .13 .09 29.9
Other voltages are available, see page 75.
87
Speed King SK-200 & Valvair II Series
Engineering Data
Catalog VAL-SK-E/USA
Technical Information
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Suggested
SK-200 1/4" Replacement
L4652910453 L4653910453
L47421211 Refer to Service Kits
L47421221 Refer to Service Kits
L47421231 Refer to Service Kits
L4752291153 Refer to Service Kits
L4752321143 Refer to Service Kits
L4752321153 L4753321153
L4752321157 L4753321157
L4752322149 Refer to Service Kits
L4752322153 Refer to Service Kits
L4752323153 Refer to Service Kits
L4752371145 Refer to Service Kits
L4752371153 Refer to Service Kits
L4752372153 Refer to Service Kits
L4752391153 Refer to Service Kits
L4752621145 Refer to Service Kits
L4752621153 L4752621153
L4752621161 Refer to Service Kits
L4752622153 Refer to Service Kits
L4752622157 Refer to Service Kits
L4752623151 Refer to Service Kits
L4752623153 Refer to Service Kits
L4752921153 L4753921153
L4752922153 Refer to Service Kits
L4752923153 Refer to Service Kits
L48421102 L48431102
L4852W10253 L4853Z10253
L4852W10453 L4853Z10453
L4852W60253 L4853Z60253
L4852W60453 L4853Z60453
L4852W80253 L4853Z80253
L4852W80453 L4853Z80453
L4852Y10253 L4853Z10253
L4852Y10453 L4853Z10453
L4852Z10253 L4853Z10253
L4852Z10453 L4853Z10453
L4852110249 L4853310249
L4852110253 L4853310253
L4852110257 L4853310257
L4852110453 L4853310453
L4852160253 L4853360253
L4852210249L L4853310249
L4852210253 L4853310253
L4852260253 L4853360253
L4852260453 L4853360453
L4852310240 Refer to Service Kits
L4852310242 Refer to Service Kits
L4852310243 Refer to Service Kits
L4852310245 Refer to Service Kits
L4852310249 L4853310249
L4852310253 L4853310253
L4852310253L L4853310253
88
Speed King SK-200 & Valvair II Series
SK-200 – 1/4"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 1/4" Replacement
L46421102 L46431102
L4652W10242 Refer to Service Kits
L4652W60453 L4653Z60453
L4652W80453 L4653Z80453
L4652Y10261 Refer to Service Kits
L4652Z10253 L4653Z10253
L4652210249 L4653310249
L4652210253 L4653310253
L4652210257 L4653310257
L4652260253 L4653360253
L4652260453 L4653360453
L4652280253 L4653380253
L4652310240 Refer to Service Kits
L4652310242 Refer to Service Kits
L4652310245 Refer to Service Kits
L4652310249 L4653310249
L4652310253 L4653310253
L4652310253L L4653310253
L4652310257 L4653310257
L4652310261 Refer to Service Kits
L4652310453 L4653310453
L4652360249 L4653360249
L4652360253 L4653360253
L4652360257 Refer to Service Kits
L4652380249 L4653380249
L4652380253 L4653380253
L4652380257 Refer to Service Kits
L4652380261 Refer to Service Kits
L4652380357 Refer to Service Kits
L4652380453 L4653380453
L4652510249 L4653610249
L4652510253 L4653610253
L4652510257 L4653610257
L4652610240 Refer to Service Kits
L4652610242 Refer to Service Kits
L4652610245 Refer to Service Kits
L4652610249 L4653610249
L4652610253 L4653610253
L4652610257 L4653610257
L4652610259 Refer to Service Kits
L4652610261 Refer to Service Kits
L4652610353 L4653610353
L4652610451 Refer to Service Kits
L4652610457 Refer to Service Kits
L4652610461 Refer to Service Kits
L4652810249 L4653810249
L4652810253 L4653810253
L4652910249 L4653910249
L4652910253 L4653910253
L4652910253L L4653910253
L4652910353 L4653910353
L4652910449 L4653910449
Suggested
SK-200 1/4" Replacement
L4852310257 L4853310257
L4852310259 Refer to Service Kits
L4852310260 Refer to Service Kits
L4852310261 Refer to Service Kits
L4852310262 Refer to Service Kits
L4852310445 Refer to Service Kits
L4852310449 L4853310449
L4852310453 L4853310453
L4852310457 Refer to Service Kits
L4852310459 Refer to Service Kits
L4852360249 L4853360249
L4852360253 L4853360253
L4852360257 L4853360257
L4852360449 L4853360449
L4852360453 L4853360453
L4852360457 Refer to Service Kits
L4852380249 L4853380249
L4852380253 L4853380253
L4852380261 Refer to Service Kits
L4852380453 L4853380453
L4852410245 Refer to Service Kits
L4852410253 L4853610253
L4852510245 Refer to Service Kits
L4852510249 L4853610249
L4852510253 L4853610253
L4852510257 L4853610257
L4852510449 L4853610449
L4852610242 Refer to Service Kits
L4852610243 Refer to Service Kits
L4852610245 Refer to Service Kits
L4852610249 L4853610249
L4852610251 Refer to Service Kits
L4852610253 L4853610253
L4852610257 L4853610257
L4852610259 Refer to Service Kits
L4852610261 Refer to Service Kits
L4852610449 L4853610449
L4852610453 L4853610453
L4852610457 Refer to Service Kits
L4852610459 Refer to Service Kits
L4852610460 Refer to Service Kits
L4852610461 Refer to Service Kits
L4852810253 L4853810253
L4852810453 L4853810453
L4852910249 L4853910249
L4852910253 L4853910253
L4852910253L L4853910253
L4852910349 L4853910349
L4852910353 L4853910353
L4852910453 L4853910453
L41421102 Refer to Service Kits
L4152110245 Refer to Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
89
Speed King SK-200 & Valvair II Series
SK-200 – 1/4"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 1/4" Replacement
Suggested
SK-200 1/4" Replacement
Suggested
SK-200 1/4" Replacement
L4152110253 L4152310253
L4152210245 Refer to Service Kits
L4152210253 L4152310253
L4152210257 L4152310257
L4152210259 Refer to Service Kits
L4152210457 Refer to Service Kits
L4152210459 Refer to Service Kits
L4152310240 Refer to Service Kits
L4152310242 Refer to Service Kits
L4152310243 Refer to Service Kits
L4152310245 Refer to Service Kits
L4152310259 Refer to Service Kits
L4152310451 Refer to Service Kits
L4152310457 Refer to Service Kits
L4152710453 L4152810453
L42421211 Refer to Service Kits
L42421221 Refer to Service Kits
L42421231 Refer to Service Kits
L4252W22549 Refer to Service Kits
L4252Z22153 Refer to Service Kits
L4252122549 Refer to Service Kits
L4252221149 L4252321149
L4252222145 Refer to Service Kits
L4252222153 Refer to Service Kits
L4252222153 Refer to Service Kits
L4252223549 Refer to Service Kits
L4252321143 Refer to Service Kits
L4252322149 Refer to Service Kits
L4252322157 Refer to Service Kits
L4252322549 Refer to Service Kits
L4252722153 Refer to Service Kits
L4252822149 Refer to Service Kits
L4252822153 Refer to Service Kits
L4252823153 Refer to Service Kits
L4252922149 Refer to Service Kits
L4252922153 Refer to Service Kits
L4252922553 Refer to Service Kits
L4252923153 Refer to Service Kits
L4252923553 Refer to Service Kits
L44421102 Refer to Service Kits
L4452W10249 L4452Z10249
L4452W10253 L4452Z10253
L4452W10449 L4452Z10449
L4452110249 L4452310249
L4452110253 L4452310253
L4452110257 L4452310257
L4452110449 L4452310449
L4452110453 L4452310453
L4452210242 Refer to Service Kits
L4452210245 Refer to Service Kits
L4452210249 L4452310249
L4452210253 L4452310253
L4452210257 L4452310257
L4452210259 Refer to Service Kits
L4452210353 L4452310353
L4452210453 L4453210453
L4452210457 Refer to Service Kits
L4452210459 Refer to Service Kits
L4452310242 Refer to Service Kits
L4452310245 Refer to Service Kits
L4452310251 Refer to Service Kits
L4452310259 Refer to Service Kits
L4452310345 Refer to Service Kits
L4452310451 Refer to Service Kits
L4452710253 L4452810253
L4452710453 L4452810453
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
90
Speed King SK-200 & Valvair II Series
SK-200 – 3/8"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 3/8" Replacement
Suggested
SK-200 3/8" Replacement
Suggested
SK-200 3/8" Replacement
L6553W10253 L6553Z10253
L6553110242 Refer to Service Kits
L6553210240 Refer to Service Kits
L6553210242 Refer to Service Kits
L6553210249 L6553310249
L6553210253 L6553310253
L6553210257 L6553310257
L6553210259 Refer to Service Kits
L6553210449 L6553310449
L6553210453 L6553310453
L6553210459 Refer to Service Kits
L6553310240 Refer to Service Kits
L6553310242 Refer to Service Kits
L6553310249S L6553310249
L6553310251 Refer to Service Kits
L6553310259 Refer to Service Kits
L6553710253 L6553810253
L6553810279 L6553810249
L6553910253S L6553910253
L6553910279 L6553910249
L6653W21153 L6653Z21153
L6653W21553 L6653Z21553
L6653221142 Refer to Service Kits
L6653221145 L6653321145
L6653221149 L6653321149
L6653221153 L6653321153
L6653221157 L6653321157
L6653222153 L6653322153
L6653223149 L6653323149
L6653223153 L6653323153
L6653223553 L6653323553
L6653321159 Refer to Service Kits
L6653721153 L6653821153
L6653721553 L6653821553
L6653821179 L6653821149
L6653923153S L6653923153
L6753W10253 L6753Z10253
L6753W10453 L6753Z10453
L6753110245 L6753310245
L6753110249 L6753310249
L6753110253 L6753310253
L6753110257 L6753310257
L6753110449 L6753310449
L6753210240 Refer to Service Kits
L6753210242 Refer to Service Kits
L6753210245 L6753310245
L6753210249 L6753310249
L6753210253 L6753310253
L6753210257 L6753310257
L6753210259 Refer to Service Kits
L6753310240 Refer to Service Kits
L6753310241 Refer to Service Kits
L6753310242 Refer to Service Kits
L6753310249S L6753310249
L6753310251 Refer to Service Kits
L6753310259 Refer to Service Kits
L6753310351 Refer to Service Kits
L6753710249 L6753810249
L6753710253 L6753810253
L6753810279 L6753810249
L6753910253S L6753910253
L685D310251 Refer to Service Kits
L685D310253 L6854310253
L685D610253 L6854610253
L685D610257L L6854640257
L685D610259 Refer to Service Kits
L685M910253 L6854910253
L6853110253 L6853310253
L6853110253L L6853310253
L6853110453 L6853310453
L6853160253 L6853360253
L6853160257 Refer to Service Kits
L6853180453 L6853380453
L6853210253 L6853310253
L6853260253 L6853360253
L6853280253 L6853380253
L6853310240 Refer to Service Kits
L6853310253L L6853310253
L6853310261 Refer to Service Kits
L6853360251 Refer to Service Kits
L6853380261 Refer to Service Kits
L6853410349 L6853610349
L6853610251 Refer to Service Kits
L6853610261 Refer to Service Kits
L6853610461 Refer to Service Kits
L6853910253L L6853910253
L6854W10242 Refer to Service Kits
L6854W10253 L6854Z10253
L6854W10453 L6854Z10453
L6854W60253 L685WZ60253
L6854110253 L6854310253
L6854110257 L6854310257
L6854110262 Refer to Service Kits
L6854210253 L6854310253
L6854210257 L6854310257
L6854260253 L6854360253
L6854280253 L6854380253
L6854280453 L6854380453
L6854110262 Refer to Service Kits
L6854210253 L6854310253
L6854210257 L6854310257
L6854260253 L6854360253
L6854280253 L6854380253
L6854280453 L6854380453
L6854310240 Refer to Service Kits
L6854310242 Refer to Service Kits
L6854310253L L6854310253
L6854310261 Refer to Service Kits
L6854360249L L6854360249
L6854380242 Refer to Service Kits
L6854380461 Refer to Service Kits
L6854410253 L6854610253
L6854410461 Refer to Service Kits
L6854510249 L6854610249
L6854510253 L6854610253
L6854610240 Refer to Service Kits
L6854610242 Refer to Service Kits
L6854610259 Refer to Service Kits
L6854610261 Refer to Service Kits
L6953121153 L6953321153
L6953121553 L6953321553
L6953122149 L6953322149
L6953122153 L6953322153
L6953122553 L6953322553
L6953271553 L6953371553
L6953272153 L6953372153
L6953292153 L6953392153
L6953321159 Refer to Service Kits
L6953322161 Refer to Service Kits
L6953371553L L6953371553
L6953422153 L6953622153
L6953521153 L6953621153
L6953621159 Refer to Service Kits
L6953621161 Refer to Service Kits
L6953622140 Refer to Service Kits
L6953721153 L6953821153
L6954W21553 L6954Z21553
L6954121153 L6954321153
L6954121345 L6954321345
L6954172153 L6954372153
L6954221145 L6954321145
L6954221153 L6954321153
L6954292153 L6954392153
L6954321142 Refer to Service Kits
L6954321145 L6954321145
L6954321149L L6954321149
L6954391149 Refer to Service Kits
L6954392149 Refer to Service Kits
L6954521553 L6954621553
L6954621142 Refer to Service Kits
L6954621143 Refer to Service Kits
L6954621161 Refer to Service Kits
L705C310253 L7053310253
L705C310259 Refer to Service Kits
L705C360253 L7053660253
L705C610253 L7053610253
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
91
Speed King SK-200 & Valvair II Series
SK-200 – 3/8"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 3/8" Replacement
Suggested
SK-200 3/8" Replacement
Suggested
SK-200 3/8" Replacement
L705C910253 L7053910253
L705D610259 Refer to Service Kits
L705D610453 L7054610453
L705M610253 L7053610253
L705N610253 L7054610253
L705N910453 L7054910453
L7053W10253 L7053Z10253
L7053W10345 L7053Z10345
L7053W10445 L7053Z10445
L7053W10449 L7053Z10449
L7053W10457 L7053Z10457
L7053110253 L7053310253
L7053110445 L7053310445
L7053110453 L7053310453
L7053160253 L7053360253
L7053160449 L7053360449
L7053160453 L7053360453
L7053180453 L7053380453
L7053210249 L7053310249
L7053210253 L7053310253
L7053260253 L705360253
L7053260257 Refer to Service Kits
L7053260453 L7053360453
L7053280253 L7053380253
L7053280453 L7053380453
L7053310242 Refer to Service Kits
L7053310259 Refer to Service Kits
L7053310260 Refer to Service Kits
L7053310261 Refer to Service Kits
L7053310440 Refer to Service Kits
L7053310461 Refer to Service Kits
L7053360251 Refer to Service Kits
L7053360253L L7053360253
L7053360453L L7053360453
L7053380245 Refer to Service Kits
L7053380249 Refer to Service Kits
L7053380253L L7053380253
L7053380445 Refer to Service Kits
L7053380449 Refer to Service Kits
L7053380461 Refer to Service Kits
L6954391161 Refer to Service Kits
L6954391561 Refer to Service Kits
L7053510257 L7053610257
L7053510261 Refer to Service Kits
L7053510453 L7053610453
L7053610242 Refer to Service Kits
L7053610259 Refer to Service Kits
L7053610261 Refer to Service Kits
L7053610461 Refer to Service Kits
L7053710253 L7053810253
L7053910253L L7053910253
L7054W10453 L7054Z10453
L7054W60253 L7054Z60253
L7054W60257 Refer to Service Kits
L7054Y10242 Refer to Service Kits
L7054Y10253 L7054Z10253
L7054110245 L7054Z10245
L7054110249 L7054310249
L7054110253 L7054310253
L7054110257 L7054310257
L7054180245 Refer to Service Kits
L7054210253 L7054310253
L7054260453 L7054360453
L7054280253 L7054380253
L7054310240 Refer to Service Kits
L7054310242 Refer to Service Kits
L7054310251 Refer to Service Kits
L7054310253L L7054310253
L7054310261 Refer to Service Kits
L7054360240 Refer to Service Kits
L7054360257 Refer to Service Kits
L7054360453L L7054360453
L7054380249 Refer to Service Kits
L7054380251 Refer to Service Kits
L7054380257 Refer to Service Kits
L7054380453L L7054380453
L7054410249 L7054610249
L7054410253 L7054610253
L7054410257 L7054610257
L7054410453 L7054610453
L7054510242 Refer to Service Kits
L7054510253 L7054610253
L7054510257 L7054610257
L7054510453 L7054610453
L7054610240 Refer to Service Kits
L7054610242 Refer to Service Kits
L7054610251 Refer to Service Kits
L7054610253L L7054610253
L7054610259 Refer to Service Kits
L7054610261 Refer to Service Kits
L7054610353L L7054610353
L7054610451 Refer to Service Kits
L7054610461 Refer to Service Kits
L7054710253 L7054810253
L7054710453 L7054810453
L7053410253 L7053610253
L7053410349 L7053610349
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
92
Speed King SK-200 & Valvair II Series
SK-200 – 1/2"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 1/2" Replacement
Suggested
SK-200 1/2" Replacement
Suggested
SK-200 1/2" Replacement
L614N1102 Refer to Service Kits
L61451102 Refer to Service Kits
L615N610253 L6156610253
L615N610257 L6156610257
L615N810253 L6156810253
L6155110453L L6156310453
L6155210449 L6156310449
L6155310242 Refer to Service Kits
L6155310249 L6156310249
L6155310253 L6156310253
L6155310257 L6156310257
L6155310261 Refer to Service Kits
L6155310349 Refer to Service Kits
L6155310462 Refer to Service Kits
L6155360253 Refer to Service Kits
L6155360257 Refer to Service Kits
L6155380253 Refer to Service Kits
L6155380449 Refer to Service Kits
L6155380453 Refer to Service Kits
L6155410253 L6156610253
L6155610249 L6156610249
L6155610253 L6156610253
L6155610257 L6156610257
L6155610261 Refer to Service Kits
L6155610453 L6156610453
L6155610461 Refer to Service Kits
L6155810453 L6156810453
L6155910253 L6156910253
L6155910453 L6156910453
L62451211 Refer to Service Kits
L62451221 Refer to Service Kits
L625N621151 Refer to Service Kits
L6255W21153 L6256Z21153
L6255Z22153 Refer to Service Kits
L6255121153 L6256321153
L6255221153 L6256321153
L6255271553 Refer to Service Kits
L6255272153 Refer to Service Kits
L6255273153 Refer to Service Kits
L6255321143 Refer to Service Kits
L6255321145 Refer to Service Kits
L6255321149 L6256321149
L6255321153 L6256321153
L6255321345 Refer to Service Kits
L6255322142 Refer to Service Kits
L6255322153 Refer to Service Kits
L6255322553 Refer to Service Kits
L6255323153 Refer to Service Kits
L6255371153 Refer to Service Kits
L6255371553 Refer to Service Kits
L6255391153 Refer to Service Kits
L6255521142 Refer to Service Kits
L6255521153 L6256621153
L6255621145 Refer to Service Kits
L6255621149 L6256621149
L6255621151 Refer to Service Kits
L6255621153 L6256621153
L6255621157 L6256621157
L6255621161 Refer to Service Kits
L6255821553 Refer to Service Kits
L6255822153 Refer to Service Kits
L6255921149 L6256921149
L6255921153 L6256921153
L6255921553 Refer to Service Kits
L6255922149 Refer to Service Kits
L6255922153 Refer to Service Kits
L6255922553 Refer to Service Kits
L6255923153 Refer to Service Kits
L64451102 Refer to Service Kits
L64461102 Refer to Service Kits
L645D360253 Refer to Service Kits
L645N310249 L6456310249
L645N310253 L6456310253
L645N310257 L6456310257
L645N610249 L6456610249
L645N610257 L6456610257
L645N910253 L6456910253
L645N910453 Refer to Service Kits
L6455W10253 L6456Z10253
L6455W80253 Refer to Service Kits
L6455Y10249 L6456Z10253
L6455Y10253 L6456Z10253
L6455Y10257 L6456Z10257
L6455Z10253 L6456Z10253
L6455110253 L6456310253
L6455210253 L6456310253
L6455280249 Refer to Service Kits
L6455310243 Refer to Service Kits
L6455310245 Refer to Service Kits
L6455310249 L6456310249
L6455310253 L6456310253
L6455310253L L6456310253
L6455310257 L6456310257
L6455310261 Refer to Service Kits
L6455310353 Refer to Service Kits
L6455310445 Refer to Service Kits
L6455310453 Refer to Service Kits
L6455360249 Refer to Service Kits
L6455360253 Refer to Service Kits
L6455360453 Refer to Service Kits
L6455380253 Refer to Service Kits
L6455380453 Refer to Service Kits
L6455410257 L6456610257
L6455410461 Refer to Service Kits
L6455510257 L6456610257
L6455510449 Refer to Service Kits
L6455610243 Refer to Service Kits
L6455610249 L6456610249
L6455610253 L6456610253
L6455610257 L6456610257
L6455610261 Refer to Service Kits
L6455610262 Refer to Service Kits
L6455610449 Refer to Service Kits
L6455610453 Refer to Service Kits
L6455610457 Refer to Service Kits
L6455610461 Refer to Service Kits
L6455710253 L6456810253
L6455810253 L6456810253
L6455810453 Refer to Service Kits
L6455910253 L6456910253
L6455910253L L6456910253
L6455910449 L6456910249
L6455910453 Refer to Service Kits
L645P310457 Refer to Service Kits
L51451102 Refer to Service Kits
L5155110249 L5155310249
L5155210249 L5155310249
L5155210253 L5155310253
L5155210453 Refer to Service Kits
L5155310242 Refer to Service Kits
L5155310245 Refer to Service Kits
L5155310259 Refer to Service Kits
L5155310353 Refer to Service Kits
L5155310442 Refer to Service Kits
L5155310449 Refer to Service Kits
L5155310451 Refer to Service Kits
L5155310453 Refer to Service Kits
L5155810449 Refer to Service Kits
L5155810453 Refer to Service Kits
L5155910349 Refer to Service Kits
L5155910353 Refer to Service Kits
L5155910453 Refer to Service Kits
L52451211 Refer to Service Kits
L52451221 Refer to Service Kits
L5255Z21553 Refer to Service Kits
L5255Z22153 Refer to Service Kits
L5255Z22153 Refer to Service Kits
L5255Z22553 Refer to Service Kits
L5255Z23553 Refer to Service Kits
L5255122153 Refer to Service Kits
L5255221149 L5255321149
L5255221153 L5255321153
L5255221557 Refer to Service Kits
L5255222149 Refer to Service Kits
L5255222153 Refer to Service Kits
L5255223153 Refer to Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
93
Speed King SK-200 & Valvair II Series
SK-200 – 1/2"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
SK-200 1/2" Replacement
Suggested
SK-200 1/2" Replacement
Suggested
SK-200 1/2" Replacement
L5255321140 Refer to Service Kits
L5255321142 Refer to Service Kits
L5255321145 Refer to Service Kits
L5255321551 Refer to Service Kits
L5255321553 Refer to Service Kits
L5255321557 Refer to Service Kits
L5255322143 Refer to Service Kits
L5255322149 Refer to Service Kits
L5255322153 Refer to Service Kits
L5255322157 Refer to Service Kits
L5255322549 Refer to Service Kits
L5255323143 Refer to Service Kits
L5255323149 Refer to Service Kits
L5255323153 Refer to Service Kits
L5255323157 Refer to Service Kits
L5255323549 Refer to Service Kits
L5255721153 L5255821153
L5255821553 Refer to Service Kits
L5255822153 Refer to Service Kits
L5255822549 Refer to Service Kits
L5255822553 Refer to Service Kits
L5255823149 Refer to Service Kits
L5255823153 Refer to Service Kits
L5255823553 Refer to Service Kits
L5255823553 Refer to Service Kits
L5255921353 Refer to Service Kits
L5255921553 Refer to Service Kits
L5255922149 Refer to Service Kits
L5255922153 Refer to Service Kits
L5255922553 Refer to Service Kits
L5255923153 Refer to Service Kits
L5255923553 Refer to Service Kits
L54451102 Refer to Service Kits
L5455Z10453 Refer to Service Kits
L5455110249 L5455310249
L5455110253 L5455310253
L5455110453 Refer to Service Kits
L5455210245 Refer to Service Kits
L5455210249 L5455310249
L5455210253 L5455310253
L5455210257 L5455310257
L5455310242 Refer to Service Kits
L5455310245 Refer to Service Kits
L5455310251 Refer to Service Kits
L5455310259 Refer to Service Kits
L5455310353 Refer to Service Kits
L5455310451 Refer to Service Kits
L5455310453 Refer to Service Kits
L5455310457 Refer to Service Kits
L5455310459 Refer to Service Kits
L5455710253 L5455810253
L5455810449 Refer to Service Kits
L5455810453 Refer to Service Kits
L5455910353 Refer to Service Kits
L5455910449 Refer to Service Kits
L5455910453 Refer to Service Kits
L6156W10242 Refer to Service Kits
L6156W10253 L615WZ10253
L6156310240 Refer to Service Kits
L6156310242 Refer to Service Kits
L6156310249L L615WZ10249
L6156310261 Refer to Service Kits
L6156310453 Refer to Service Kits
L6156360253 Refer to Service Kits
L6156380253 Refer to Service Kits
L6156410253 L6156610253
L6156510249 L6156610249
L6156610245 Refer to Service Kits
L6156610261 Refer to Service Kits
L6156610453 Refer to Service Kits
L6156610461 Refer to Service Kits
L6156810453 Refer to Service Kits
L6156910353 Refer to Service Kits
L6156910449L Refer to Service Kits
L6256W21153 L6256Z21153
L6256121145L Refer to Service Kits
L6256121153 L6256321153
L6256171153 Refer to Service Kits
L6256221153 L6256321153
L6256321553 Refer to Service Kits
L6256321557 Refer to Service Kits
L6256322149 Refer to Service Kits
L6256322153 Refer to Service Kits
L6256371153 Refer to Service Kits
L6256371553 Refer to Service Kits
L6256372153 Refer to Service Kits
L6256391153 Refer to Service Kits
L6256392149 Refer to Service Kits
L6256392153 Refer to Service Kits
L6256393153 Refer to Service Kits
L6256621140 Refer to Service Kits
L6256621145 Refer to Service Kits
L6256621161 Refer to Service Kits
L6256621561 Refer to Service Kits
L6256622153 Refer to Service Kits
L6256622157 Refer to Service Kits
L6256622353 Refer to Service Kits
L6256921353 Refer to Service Kits
L6256921549 Refer to Service Kits
L6256921553 Refer to Service Kits
L6256922153 Refer to Service Kits
L6256922549 Refer to Service Kits
L6256922553 Refer to Service Kits
L6256923153 Refer to Service Kits
L645P310457 Refer to Service Kits
L645P610253 L6456610253
L645P610257 L6456610257
L645P610453 Refer to Service Kits
L645P910253 L6456910253
L6456W10251 Refer to Service Kits
L6456W10253 L6456Z10253
L6456W10453 Refer to Service Kits
L6456W60253 Refer to Service Kits
L6456W60257 Refer to Service Kits
L6456W80249 Refer to Service Kits
L6456W80253 Refer to Service Kits
L6456W80257 Refer to Service Kits
L6456W80453 Refer to Service Kits
L6456Y10249 L6456Z10249
L6456Y10257 L6456Z10257
L6456110253 L6456310253
L6456110453 Refer to Service Kits
L6456210253 L6456310253
L6456280453 Refer to Service Kits
L6456280457 Refer to Service Kits
L6456310261 Refer to Service Kits
L6456310445 Refer to Service Kits
L6456310453 Refer to Service Kits
L6456310457 Refer to Service Kits
L6456360249 Refer to Service Kits
L6456360253 Refer to Service Kits
L6456360257 Refer to Service Kits
L6456360453 Refer to Service Kits
L6456380245 Refer to Service Kits
L6456380253 Refer to Service Kits
L6456380253L Refer to Service Kits
L6456380445 Refer to Service Kits
L6456380453 Refer to Service Kits
L6456510253 L6456610253
L6456610245 Refer to Service Kits
L6456610251 Refer to Service Kits
L6456610259 Refer to Service Kits
L6456610261 Refer to Service Kits
L6456610449 Refer to Service Kits
L6456610449 Refer to Service Kits
L6456610453 Refer to Service Kits
L6456610453 Refer to Service Kits
L6456610461 Refer to Service Kits
L6456710253 L6456810253
L6456810453 Refer to Service Kits
L6456810453 Refer to Service Kits
L6456910353 Refer to Service Kits
L6456910353 Refer to Service Kits
L6456910453 Refer to Service Kits
L6456910453 Refer to Service Kits
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
94
Speed King SK-200 & Valvair II Series
Valvair II – 1"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
Valvair II 1" Replacement
Suggested
Valvair II 1" Replacement
Suggested
Valvair II 1" Replacement
L6558110257 L6558310257
L6558210249 L6558310249
L6558210253 L6558310253
L6558210257 L6558310257
L6558210259 Refer to Service Kits
L6558210459 Refer to Service Kits
L6558310242 Refer to Service Kits
L6558310243 Refer to Service Kits
L6558310251 Refer to Service Kits
L6558310259 Refer to Service Kits
L6558310451 Refer to Service Kits
L6558710253 L6558710253
L6658121153 L6658321153
L6658122157 L6658322157
L6658221149 L6658321149
L6658221153 L6658321153
L6658221157 L6658321157
L6658221159 Refer to Service Kits
L6658221549 L6658321549
L6658321551 Refer to Service Kits
L6658722153 L6658822153
L6658923153 Refer to Service Kits
L6758W10249 L6758Z10249
L6758110249 L6758310249
L6758110253 L6758310253
L6758210249 L6758310249
L6758210253 L6758310253
L6758210257 L6758310257
L6758210259 Refer to Service Kits
L6758210453 L6758310453
L6758310241 Refer to Service Kits
L6758310242 Refer to Service Kits
L6758310259 Refer to Service Kits
L6758310440 Refer to Service Kits
L6758310451 Refer to Service Kits
L6758710253 L6758810253
L68471102 L68481102
L68491102 L68481102
L6857210253 L6858310253
L6857210257 L6858310257
L6857210253 L6858310253
L6857210257 L6858310257
L6857280453 L6858380453
L6857280457 Refer to Service Kits
L6857310240 Refer to Service Kits
L6857310253 L6858310253
L6857310349 L6858310349
L6857310359 Refer to Service Kits
L6857360253 L6858360253
L6857380249 Refer to Service Kits
L6857380253 L6858380253
L6857380257 Refer to Service Kits
L6857380453 L6858380453
L6857410249 L6858610249
L6857510253 L6858610253
L6857610253 L6858610253
L6857610261 Refer to Service Kits
L6857610353 L6858610353
L6857610457 L6858610457
L6857810253 L6858810253
L6857810453 L6858810453
L6857910249 L6858910249
L6857910253 L6858910253
L6857910353 L6858910353
L6858180353 L6858280353
L6858180361 Refer to Service Kits
L6858210253 L6858310253
L6858380461 Refer to Service Kits
L6858410257 L6858610257
L6858410353 L6858610353
L6858410361 Refer to Service Kits
L6858410453 L6858610453
L6858410461 Refer to Service Kits
L6858510249 L6858610249
L6859210253 L6858310253
L6859310253 L6858310253
L6859310257 L6858310257
L6859310261 Refer to Service Kits
L6859360253 L6858390653
L6859410257 L6858610257
L6859610245 L6858610245
L6859610249 L6858610249
L6859610253 L6858610253
L6859610261 Refer to Service Kits
L6859810253 L6858810253
L6859910249 L6858910249
L6859910253 L6858910253
L69471211 L69481211
L69471221 L69481221
L69471231 Refer to Service Kits
L69491211 L69481211
L6957121145L L6958321145
L6957221153 L6958321153
L6957221553 L6958321553
L6957291553 L6958391553
L6957321149 L6958321149
L6957321153 L6958321153
L6957321157 L6958321157
L6957322149 L6958322149
L6957322153 L6958322153
L6957371153 L6958371153
L6957391153 L6958391153
L6957391549 L6958391549
L6957392153 L6958392153
L6957621149 L6958621149
L6957621153 L6958621153
L6957621157 L6958621153
L6957622153 L6958622153
L6957623153 Refer to Service Kits
L6957921149 L6958921149
L6957921153 L6958921153
L6957921553 L6958921553
L6957922153 L6958922153
L6957923153 Refer to Service Kits
L6958121153 L6958321153
L6958272153 L6958372153
L6958422157 L6958622157
L6958521153 L6958621153
L6958722153 L69588822153
L6958923153 Refer to Service Kits
L6959271153 L6958371153
L6959272153 L6958372153
L6959291153 L6958391153
L6959422157 L6958622157
L6959523153 Refer to Service Kits
L6959623157 Refer to Service Kits
L6959923153 Refer to Service Kits
L70471102 L70481102
L70491102 L70481102
L7057Z10253 L7058Z10253
L7057210253 L7058310253
L7057260453 L7058360453
L7057280453 L7058380453
L7057310245 L7058310245
L7057310249 L7058310249
L7057310253 L7058310253
L7057310257 L7058310257
L7057310261 Refer to Service Kits
L7057310453 L7058310453
L7057360249 L7058360249
L7057360253 L7058360253
L7057360449 L7058360449
L7057360453 L7058360453
L7057380249 Refer to Service Kits
L7057380253 L7058380253
L7057410253 L7058610253
L7057510253 L7058610253
L7057610245 L7058610245
L7057610249 L7058610249
L7057610253 L7058610253
L7057610257 L7058610257
L7057610449 L7058610449
L7057610457 L7058610457
L7057810253 L7058810253
L7057910249 L7058910249
L7057910253 L7058910253
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
95
Speed King SK-200 & Valvair II Series
Valvair II – 1"
Catalog VAL-SK-E/USA
Standard Product Crossover Information
Suggested
Valvair II 1" Replacement
Suggested
Valvair II 1" Replacement
Suggested
Valvair II 1" Replacement
L7057910353 L7058910353
L7057910453 L7058910453
L7058W80453 L7058Z80453
L7058Y10253 L7058Z10253
L7058Y10445 L7058Z10445
L7058210253 L7058310253
L7058260453 L7058360453
L7058280253 L7058380253
L7058280453 L7058380453
L7058380253L L7058380253
L7058380453L L7058380453
L7058610243 Refer to Service Kits
L7058610461 Refer to Service Kits
L7059Z10253 L7058Z10253
L7059110253 L7058310253
L7059210253 L7058310253
L7059210257 L7058310257
L7059280453 L7058380453
L7059310249 L7058310249
L7059310253 L7058310253
L7059310257 L7058310257
L7059360249 L7058360249
L7059360253 L7058360253
L7059380253 L7058380253
L7059410253 L7058610253
L7059610249 L7058610249
L7059610253 L7058610253
L7059610257 L7058610257
L7059610261 Refer to Service Kits
L7059810253 L7058810253
L7059810453 L7058810453
L7059910249 L7058910249
L7059910253 L7058910253
L7059910453 L7058910453
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
96
Speed King SK-200 & Valvair II Series
SK-200 – 1/4"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 1/4"
Specials Description Repair Kit Closest Replacement
L38053001 Single Solenoid, less base, with fluorocarbon seals N/A L38539104 + voltage
L38054001 Single Solenoid, less base, less pilot valve K352088 L3854 X 102 + voltage
L41052001 Plug-In Speed King Valve with lubrication for dry service K352151 L41529102 + voltage
L41052002 Plug-In Speed King Valve with indicator light for 230 / 50Hz K352151 L4152310257
L41052003 Plug-In Speed King Valve with Lockwire and “VH” O-rings K352151 L41529102 + voltage
L41052004 Plug-In Valve one remote cap and one remote time delay and K352151 L41421102 + Time Delay
less electrical plug
L41052005 Less subbase with remote caps and less electrical plug K352357 L41421102
L41052006 Plug-In Valve with Lockwire on end caps and Lockwired to subbase K352151 L41529102 + voltage
L41052007 Plug-In Valve less O-rings K352151 L41529102 + voltage
L41052008 Less subbase Plug-In Speed King with Lockwire and special pilot K352151 L4152910253
L41052009 Plug-In Valve with poly N/A N/A
L41052010 Plug-In Valve less Buna N O-rings with polyurethane O-rings N/A L41529104 + voltage
L41052011 Double Solenoid with special sealing agent on electrical plug K352151 L4152910253
L41052012 Double Solenoid with stainless steel spool K352151 N/A
L41052013 Double Solenoid with fluorocarbon seals N/A N/A
L42052001 Double Solenoid with speed controllers K352151 L42529231** + 003381101
L42052002 Double Solenoid with speed controllers K352151 L42529211** + 003381101
L42052003 Double Solenoid, for dry service lubrication K352151 L42529211 + voltage
L42052004 Double Solenoid, with special O-rings N/A L42529211 + voltage
L42052005 Double Solenoid, with urethane O-rings N/A N/A
L42052006 Double Solenoid, with Normally Open and Normally Closed pilots K352151 L42529211 + voltage
L42052007 Double Solenoid, ABP, with stainless steel spool K352151 N/A
L42052008 Double Solenoid, CE, with stainless steel spool K352151 N/A
L42052009 Double Solenoid, PC, with stainless steel spool K352151 N/A
L44052001 Single Solenoid, for non-lube service K352150 L44529102 + voltage
L44052002 Single Solenoid, lubricated with Lubri-Plate N/A N/A
L44052003 Single Solenoid, for non-lube service K352150 L44529102 + voltage
L44052004 Single Solenoid, with lighted 230 / 50Hz lighted coil K352150 L4452310257
L44052005 Single Solenoid, with high temperature seals N/A N/A
L44052006 Single Solenoid, with remote operators K352363 L44421102
L44052007 Single Solenoid, with high temperature seals N/A N/A
L44052008 Single Solenoid, with special end caps and pilot valve K352150 N/A
L44052009 Single Solenoid, with VH O-rings N/A N/A
L44052010 Single Solenoid, with sealing agent on electrical plug K352150 L44523102 + voltage
L44052011 Single Solenoid, with special piston for external pilot thru pilot inlet K352150 N/A
L44052012 Single Solenoid, with polyurethane O-rings N/A N/A
L44052013 Single Solenoid, with polyurethane O-rings and 200 PSI pilot N/A N/A
L44052014 Single Solenoid, with solid state controls K352150 N/A
L44052015 Single Solenoid, with sealing agent on electrical plug K352150 L44529102 + voltage
L44052016 Single Solenoid, with stainless steel spool K352150 N/A
L44052017 Single Solenoid, lubricated with Lubri-Plate N/A N/A
L44052018 Single Solenoid, with fluorocarbon seals and high temperature coil N/A N/A
L44052019 Single Solenoid, with fluorocarbon seals and high temperature coil N/A N/A
L46042001 Double Remote Pilot, with time delay K352357 L46421102 + time delay module
L46042002 Double Remote Pilot, with internal pilot supply K352357 N/A
L46042003 Double Remote Pilot, with cylinder operators K352357 N/A
L46042004 Double Remote Pilot, with time delay K352357 L46421102 + time delay module
L46042005 Double Remote Pilot, with fluorocarbon O-rings N/A N/A
L46043001 Double Remote Pilot, with adapters for air bleed assemblies K352357 N/A
L46052001 Double Solenoid, with special coil K352151 N/A
L46052002 Double Solenoid, with special coil K352151 N/A
L46052003 Double Solenoid, with external pilot supply K352151 L4652410**
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
97
Speed King SK-200 & Valvair II Series
SK-200 – 1/4"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 1/4"
Specials Description Repair Kit Closest Replacement
L46052004 Double Solenoid, with special lubricant N/A N/A
L46052005 Double Solenoid, with high temperature - Nema 4 coil, 125VDC K352151 N/A
L46052006 Double Solenoid, with special pilot K352151 N/A
L46052007 Double Solenoid, less pilot valve K352151 L4652 * 102 **
L46052008 Double Solenoid, with BSPT threads K352151 N/A
L46053001 Double Solenoid, with high temperature coil K352151 N/A
L46053002 Double Solenoid, with special pilot orientation K352151 L46533602**
L46053003 Double Solenoid, with suppressors K352151 N/A
L46053004 Double Solenoid, with 250VDC coils K352151 N/A
L46053005 Double Solenoid, with special 125VDC coil K352151 N/A
L47042001 Double Remote Pilot, with special remote adapters K352357 N/A
L47043001 Double Remote Pilot, with special stem K352357 N/A
L47052001 Double Solenoid, with 1 - NO pilot and 1 - NC pilot K352151 N/A
L47052002 Double Solenoid, with 1 - NO pilot and 1 - NC pilot K352151 N/A
L47052003 Double Solenoid, with 1 - NO pilot and 1 - NC pilot K352151 N/A
L47053001 Double Solenoid, with 1 - NO pilot and 1 - NC pilot K352151 N/A
L47053002 Double Solenoid, with 1 - NO pilot and 1 - NC pilot K352151 N/A
L47053003 Double Solenoid, with special stem K352151 N/A
L47053004 Double Solenoid, with speed controls K352151 L47533211 + voltage and flow controls
L48042001 Single Remote Pilot, inline valve, with special remote cap K352363 N/A
L48042003 Single Remote Pilot, inline valve, with fluorocarbon O-rings N/A N/A
L48043001 Single Remote Pilot, inline valve, with special pilot cap K352363 L48431102
L48052001 Single Solenoid, inline valve, with high temperature seals N/A N/A
L48052002 Single Solenoid, inline valve, with special lubrication N/A N/A
L48052003 Single Solenoid, inline valve, with high temperature seals N/A N/A
L48052004 Single Solenoid, inline valve, with Class “H coil, 115V / 60Hz, K352150 N/A
continuous duty
L48052005 Single Solenoid, inline valve, with Class “H” coil, 125VDC, K352150 N/A
hazardous location
L48052006 Single Solenoid, inline valve, less coil K352150 L48529102 **
L48052007 Single Solenoid, inline valve, with special pilot, less coil K352150 N/A
L48052008 Single Solenoid, inline valve, with special NC pilot valve K352150 N/A
L48052009 Single Solenoid, inline valve, with polyurethane O-rings K352150 N/A
L48052010 Single Solenoid, inline valve, with special lubrication N/A N/A
L48052011 Single Solenoid, inline valve, with 6 foot leads on coils K352150 L48523102 + voltage
L48052012 Single Solenoid, inline valve, with suppressors K352150 L48529102 + voltage
L48052013 Single Solenoid, inline valve, with special override and 36 inch leads K352150 L48529102 + voltage
L48052014 Single Solenoid, inline valve, with 36 inch leads K352150 L4852310253
L48052015 Single Solenoid, inline valve, less coil K352150 L48523604 + voltage
L48053001 Single Solenoid, inline valve, with Class “H” coil, Nema 4, 115V / 60Hz K352150 N/A
L48053002 Single Solenoid, inline valve, with Class “H” coil, hazardous and K352150 N/A
continuous duty
L48053003 Single Solenoid, inline valve, with special non-locking override K352150 L48536102 + voltage
L48053004 Single Solenoid, inline valve, with Class “H” coil, Nema 4 K352150 N/A
L48053005 Single Solenoid, inline valve, with Class “H” coil, Nema 4 125VDC K352150 N/A
L48053006 Single Solenoid, inline valve, with fluorocarbon seals N/A N/A
L48053007 Single Solenoid, inline valve, with special non-locking override K352150 L4853610253
L48053008 Single Solenoid, inline valve, with special 125VDC coil K352150 N/A
L48053009 Single Solenoid, inline valve, with 55V / 60Hz rating K352150 N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
98
Speed King SK-200 & Valvair II Series
SK-200 – 3/8"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 3/8"
Specials Description Repair Kit Closest Replacement
L6504C001 Double Remote Pilot, with subbase, with fluorocarbon N/A N/A
L65053001 Double Solenoid, less base, with drilled pilot exhaust K352126 L65533102 + voltage
L65053002 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553910253
L65053003 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553810253
L65053004 Double Solenoid, less base, with drilled pilot exhaust K352126 L65532102 + voltage
L65053005 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553210261
L65053006 Double Solenoid, less base, with fluorocarbon O-rings N/A N/A
L65053007 Double Solenoid, less base, with blank pilot spacer K352126 N/A
L65053008 Double Solenoid, less base, with one NC and one NO solenoid K352126 N/A
L65053009 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053010 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053011 Double Solenoid, less base, with class “H” coil and 10 foot leads K352126 N/A
L65053012 Double Solenoid, less base, with special spool K352126 N/A
L65053013 Double Solenoid, less base, with drilled pilot exhaust K352126 N/A
L65053014 Double Solenoid, less base, with blocked inlet port K352126 N/A
L65053015 Double Solenoid, less base, with blocked inlet port K352126 N/A
L65053016 Double Solenoid, less base, with blocked exhaust ports K352126 N/A
L65053017 Double Solenoid, less base, with gasket plate K352126 L65539102 + voltage
L65053018 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053019 Double Solenoid, less base, with special spring return override K352126 L6553910253
L65053020 Double Solenoid, less base, with low-temperature lube and N/A N/A
stainless steel spool
L65053021 Double Solenoid, less base, with blocked inlet port K352126 N/A
L66043001 Double Remote Pilot, with special drilling K352355 N/A
L66043002 Double Remote Pilot, with special drilling K352355 N/A
L66043003 Double Remote Pilot, with locking overrides K352355 L66431221
L66053001 Double Solenoid, less base, with one NO and one NC solenoid K352126 N/A
L66053003 Double Solenoid, less base, with plugged override on “B” solenoid K352126 L66532231
L66053004 Double Solenoid, less base, with blank exhaust spacers K352126 N/A
L66053005 Double Solenoid, less base, with one continuous duty solenoid and K352126 N/A
special pistons
L66053006 Double Solenoid, less base, with blank exhaust spacers K352126 N/A
L66053007 Double Solenoid, less base, with 75VDC coil K352126 N/A
L66053008 Double Solenoid, less base, with 125VDC coil K352126 L6653221161
L66053009 Double Solenoid, with base, with grounding screw in base K352126 L66539211 + voltage
L66053011 Double Solenoid, less base, with one NO and one NC solenoid K352126 N/A
L66053012 Double Solenoid, less base, with 32VDC coil K352126 N/A
L66053014 Double Solenoid, less base, with remote adapters K352126 N/A
L66053015 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053016 Double Solenoid, less base, with one NO and one NC solenoid K352126 N/A
L66053018 Double Solenoid, less base, with special override K352126 L6653923153
L66053019 Double Solenoid, less base, with conduit type operators K352126 N/A
L66053020 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053021 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053022 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053024 Double Solenoid, less base, with 37VDC coil K352126 N/A
L67043001 Single Remote Pilot, Valve only, with timing sequence delay K352362 L67431102 + K7051003
L67043002 Single Remote Pilot, Valve only, with timing sequence delay K352362 L67431102 + K7051002
L67053001 Single Solenoid, Valve only, with fluorocarbon O-rings, 115VAC / 60Hz N/A N/A
L67053002 Single Solenoid, Valve only, with spring return K352124 L67539102 + voltage
L67053005 Single Solenoid, Valve only, with NC pilot using adapters K352124 N/A
L67053007 Single Solenoid, Valve only, with blank end spacers K352124 N/A
L67053008 Single Solenoid, Valve only, with blank end spacers K352124 N/A
L67053009 Single Solenoid, Valve only, with blank end spacers, 120VAC K352124 N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
99
Speed King SK-200 & Valvair II Series
SK-200 – 3/8"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 3/8"
Specials Description Repair Kit Closest Replacement
L67053010 Single Solenoid, Valve only, with stainless steel spool K352124 N/A
L67053011 Single Solenoid, Valve only, with 3-pin Brad Harrison connector K352124 L67539102 + voltage
L67053012 Single Solenoid, Valve only, with 3-pin Brad Harrison connector K352124 L67539102 + voltage
L67053013 Single Solenoid, Valve only, with high temperature seal and coil N/A N/A
less shockpad
L67053014 Single Solenoid, Valve only, with fluorocarbon O-rings N/A N/A
L67053015 Single Solenoid, Valve only, with internal exhaust drilling K352124 N/A
L67053016 Single Solenoid, Valve only, with blank spacer at inlet K352124 N/A
L67053017 Single Solenoid, Valve only, with gasket plate K352124 L6753910453
L67053018 Single Solenoid, Valve only, with 75VDC coil K352124 N/A
L67053019 Single Solenoid, Valve only, with 125VDC coil K352124 L6753210261
L67053020 Single Solenoid, Valve only, with 32VDC coil K352124 N/A
L67053021 Single Solenoid, Valve only, with special spring return override K352124 L6753910253
L67053023 Single Solenoid, valve only, with fluorocarbon O-rings N/A N/A
L67053024 Single Solenoid, valve only, with JIC pilot valve K352124 N/A
L67053025 Single Solenoid, valve only, with high temperature seal and coil, N/A N/A
external pilot
L67053027 Single Solenoid, valve only, with blank spacer at inlet, 24VDC K352124 N/A
L67053028 Single Solenoid, valve only, with blank end spacers, 24VDC K352124 N/A
L67053029
Single Solenoid, valve with base, with high temperature seal and coil, 24VDC
N/A N/A
L67053030
Single Solenoid, valve with base, with high temperature seal and coil, 120VAC
N/A N/A
L68044001 Double Remote Pilot, inline valve, with special air bleed remote adapters K352355 N/A
L68054001 Double Solenoid, inline valve, with high temperature seals and coil, N/A N/A
NEMA 4, 120VAC
L68054002 Double Solenoid, inline valve, with stainless steel spool, 120VAC K352126 N/A
L68054003 Double Solenoid, inline valve, with stainless steel spool, 24VDC K352126 N/A
L68054004 Double Solenoid, inline valve, with stainless steel spool, 120VAC K352126 N/A
L68054005 Double Solenoid, inline valve, with high temperature seals N/A N/A
L68054006 Double Solenoid, inline valve, with high temperature seals and coil, N/A N/A
NEMA 4, 120VAC
L69043001 Double Remote Pilot, inline valve, with special drilling in body K352355 N/A
L69044001 Double Remote Pilot, inline valve, with special drilling in body K352355 N/A
L69053001 Double Solenoid, inline valve, with stainless steel spool K352126 N/A
L69054001 Double Solenoid, inline valve, with class “H” coil, 120VAC K352126 N/A
L69054002 Double Solenoid, inline valve, with hazardous duty solenoid K352126 L69543721 + voltage
L69054003 Double Solenoid, inline valve, with two NC solenoids and adapter K352126 N/A
L69054004 Double Solenoid, inline valve, with speed controls K352126 L6954321553 + flow controls
L70044001 Single Remote Pilot, inline valve, with fluorocarbon O-rings N/A N/A
L70044002 Single Remote Pilot, inline valve, with offset spring K352362 L70441102
L70053001 Single Solenoid, inline valve, with stainless steel spool K352124 N/A
L70053003 Single Solenoid, inline valve, with suppressors K352124 L70539102 + voltage
L70053004 Single Solenoid, inline valve, with 32VDC coil, and special service gasket K352124 N/A
L70053005 Single Solenoid, inline valve, with 250VDC coil K352124 N/A
L70053006 Single Solenoid, inline valve, with special grease and hydraulic gasket N/A N/A
L70054001 Single Solenoid, inline valve, with 48VDC coil, class “H” coil, N/A N/A
fluorocarbon O-rings
L70054002 Single Solenoid, inline valve, with 48VDC coil, class “H” coil, N/A N/A
fluorocarbon O-rings
L70054003 Single Solenoid, inline valve, with class “H” coil, fluorocarbon O-rings N/A N/A
L70054004 Single Solenoid, inline valve, with suppressors K352124 L70549102 + voltage
L70054005 Single Solenoid, inline valve, with stainless steel spool K352124 N/A
L70054006 Single Solenoid, inline valve, with class “H” coil, and special name tag K352124 N/A
L70054007 Single Solenoid, inline valve, with 48 inch leads K352124 L7054610257
L70054008 Single Solenoid, inline valve, with fluorocarbon O-rings and 48VDC coil N/A N/A
L70054009 Single Solenoid, inline valve, with fluorocarbon O-rings N/A N/A
L70054010 Single Solenoid, inline valve, Nema 4 solenoid with 24VDC class “B” coil N/A N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
100
Speed King SK-200 & Valvair II Series
SK-200 – 1/2"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 1/2"
Specials Description Repair Kit Closest Replacement
L51045001 Double Remote Pilot, less base, with sequence timer K352358 L51451102 + timer
L51045002 Double Remote Pilot, less base, with air bleed K352358 N/A
L51055001 Double Solenoid, less base, with special lubrication N/A N/A
L51055002 Double Solenoid, less base, with blocked exhaust ports K352153 N/A
L51055003 Double Solenoid, less base, with aluminum spool K352153 N/A
L51055004 Double Solenoid, less base, with light 240VAC K352153 L5155310257
L51055005 Double Solenoid, less base, with remote pilot adapter K352153 N/A
L51055006 Double Solenoid, less base, with one remote pilot adapter K352153 N/A
L51055007 Double Solenoid, less base, with drilled internal pilot supply K352153 N/A
L51055009 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L51055010 Double Solenoid, less base, with stainless steel spool K352153 N/A
L51055011 Double Solenoid, less base, less pilot K352153 L51451102
L51055012 Double Solenoid, less base, with special override K352153 L5155910253
L51055013 Double Solenoid, less base, with special plate to raise pilot K352153 N/A
L52055001 Double Solenoid, less base, lubricated for non-lube service N/A N/A
L52055002 Double Solenoid, less base, with remote adapter K352153 N/A
L52055004 Double Solenoid, less base, with lead sealing agent K352153 L52553221 + voltage
L52055005 Double Solenoid, less base, with 230VDC coil K352153 N/A
L52055006 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L52055007 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L52055008 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L52055009 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L52055010 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055011 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055012 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055013 Double Solenoid, with base, with 5-pin connector in base K352153 L5255921153
L52055014 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L54055001 Single Solenoid, less base, lubricated with special grease N/A N/A
L54055002 Single Solenoid, less base, with special coated spool K352152 N/A
L54055004 Single Solenoid, less base, with light for 240VAC K352152 L5455310257
L54055005 Single Solenoid, less base, with remote pilot adapter K352152 N/A
L54055006 Single Solenoid, less base, with shock pads K352152 L54558102 + voltage
L54055007 Single Solenoid, less base, with lead sealing agent K352152 L54553102 + voltage
L54055008 Single Solenoid, less base, with non-plug in pilot valve K352152 N/A
L54055009 Single Solenoid, less base, with NEMA 4 pilot K352152 N/A
L54055010
Single Solenoid, less base, with internal / external pilot supply convertibility
K352152 L54554102 + voltage
L54055011 Single Solenoid, less base, with conduit connection and K352152 N/A
Brad Harrison connector
L54055014 Single Solenoid, less base, with conduit connection K352152 N/A
L54055015 Single Solenoid, less base, with stainless steel spool K352152 N/A
L54055016 Single Solenoid, less base, less pilot K352152 N/A
L54055017 Single Solenoid, less base, with raised electrical connection K352152 N/A
L61055001 Double Solenoid, inline, with drilled internal pilot exhaust K352153 N/A
L61055002 Double Solenoid, inline, with 50VAC / 50Hz coil K352153 N/A
L61056001 Double Solenoid, inline, with class “H” coil, 120VAC / 60Hz K352153 N/A
L62045001 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62046001 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62046002 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62056001 Double Solenoid, inline, with 75VDC coil K352153 N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
101
Speed King SK-200 & Valvair II Series
SK-200 – 1/2"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
SK200 1/2"
Specials Description Repair Kit Closest Replacement
L62056002 Double Solenoid, inline, with 48VAC / 50Hz coil K352153 N/A
L62056003 Double Solenoid, inline, with 75VDC coil K352153 N/A
L62056004 Double Solenoid, inline, with 37VDC coil K352153 N/A
L64046001 Single Remote Pilot, inline, with fluorocarbon seals N/A N/A
L64055001 Single Solenoid, inline, with special override K352151 L6455510253
L64056001 Single Solenoid, inline, with “VH” O-rings N/A N/A
L64056002 Single Solenoid, inline, with special service pilot and class “H” coil K352151 N/A
L64056003 Single Solenoid, inline, with class “H” coil, 115VAC / 60Hz K352151 N/A
L64056004 Single Solenoid, inline, with class “H” coil, 115VAC / 60Hz K352151 N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
102
Speed King SK-200 & Valvair II Series
Valvair II – 1"
Catalog VAL-SK-E/USA
Specials History & Crossover Information
Valvair II 1"
Specials Description Repair Kit Closest Replacement
L65058001 Double Solenoid, less base, with NC pilot K352130 N/A
L65058002 Double Solenoid, less base, with NC pilot and light K352130 N/A
L65058003 Double Solenoid, less base, with NC pilot K352130 N/A
L65058004 Double Solenoid, less base, with NC pilot K352130 N/A
L65058005 Double Solenoid, less base, with conduit operator connection K352130 N/A
L65058006 Double Solenoid, with base, with Brad Harrison connection in base K352130 L6558810253
L65058007 Double Solenoid, less base, with Brad Harrison connection in pilot K352130 N/A
L65058008 Double Solenoid, less base, less pilot K352130 L6558910253
L66058001 Double Solenoid, less base, with blank spacers at exhaust K352130 N/A
L66058002 Double Solenoid, less base, with one continuous duty solenoid K352130 N/A
L66058003 Double Solenoid, less base, with 75VDC coil K352130 N/A
L66058004 Double Solenoid, less base, with one remote pilot operator K352130 N/A
L66058005 Double Solenoid, less base, with special pilot K352130 N/A
L67058001 Single Solenoid, less base, with 120VAC class “H” coil and 10 foot leads K352128 N/A
L67058002 Single Solenoid, less base, with 4-pin connector in pilot K352128 N/A
L67058003 Single Solenoid, less base, with NEMA 4 JIC pilot K352128 N/A
L67058004 Single Solenoid, less base, less pilot K352128 L6758910253
L69057001 Double Solenoid, inline, with spotfaces on ports K352130 N/A
L70057001 Single Solenoid, inline, with suppressors K352128 N/A
L70058001 Single Solenoid, inline, with class “H” coil, 48VDC K352128 N/A
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
103
Speed King SK-200 & Valvair II Series
A4, A5 Series Specials
Catalog VAL-SK-E/USA
Parker Specials Crossover Information
A4 or A5
Specials Description Repair Kit Closest Replacement
A4C1A43Y001 Single Solenoid, inline valve, with fluorocarbon seals and K35020050 + K352366 L7054380453 - with Buna N seal
class H coil
A4C1A43Y002 Single Solenoid, inline valve, with fluorocarbon seals and K35020050 + K352366 L7054380453 - with Buna N seal
external pilot
A431A43Y001 Single Solenoid, with special non-locking override K352124 L7054510253
A431531Y001 Single Solenoid, with base, with 60VAC / 60Hz coil and K352124 N/A
BSPP ports
A431533Y001 Single Solenoid, with base, with 3-pin connector in base K352124 L6753910253 + K022090
A431543Y001 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910253 + K022091
external pilot
A431543Y002 Single Solenoid, with base, with special non-locking override K352124 L6753810253 + K022091
A431553Y001 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910253 + K022101
external pilot
A431553Y002 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910249 + K022101
external pilot
A441VXXY001 Double Solenoid, less base, with anodized body K352126 L6553210257
A441533Y001 Double Solenoid, with base, with 3-pin connector in base K352126 L6553910253 + K022090
A471553Y001 Single Remote Pilot, with base, with special pilot adapter K352362 L67431102 + K022101
A531A53Y001 Single Solenoid, inline valve, with 200 PSI pilot K352152 L6453210353
A531553Y001 Single Solenoid, with base, with 200 PSI pilot K352152 L5455210353 + K022093
Pneumatic
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
104
Catalog VAL-SK-E/USA
Notes
05/17
PARKER-HANNIFIN CORPORATION
OFFER OF SALE
1. Definitions. As used herein, the following terms have the meanings indicated.
Buyer: means any customer receiving a Quote for Products from Seller.
Goods: means any tangible part, system or component to be supplied by
the Seller.
Products: means the Goods, Services and/or Software as described in a
Quote provided by the Seller.
Quote: means the offer or proposal made by Seller to Buyer for the supply
of Products.
Seller: means Parker-Hannifin Corporation, including all divisions and
businesses thereof.
Services: means any services to be supplied by the Seller.
Software: means any software related to the Products, whether embedded
or separately downloaded.
Terms: means the terms and conditions of this Offer of Sale or any newer
version of the same as published by Seller electronically at
www.parker.com/saleterms.
2. Terms. All sales of Products by Seller are contingent upon, and will be governed by, these Terms
and, these Terms are incorporated into any Quote provided by Seller to any Buyer. Buyer’s order for
any Products whether communicated to Seller verbally, in writing, by electronic date interface or other
electronic commerce, shall constitute acceptance of these Terms. Seller objects to any contrary or
additional terms or conditions of Buyer. Reference in Seller's order acknowledgement to Buyer's
purchase order or purchase order number shall in no way constitute an acceptance of any of Buyer's
terms of purchase. No modification to these Terms will be binding on Seller unless agreed to in
writing and signed by an authorized representative of Seller.
3. Price; Payment. The Products set forth in Seller's Quote are offered for sale at the prices
indicated in Seller’s Quote. Unless otherwise specifically stated in Seller’s Quote, prices are valid for
thirty (30) days and do not include any sales, use, or other taxes or duties. Seller reserves the right
to modify prices at any time to adjust for any raw material price fluctuations. Unless otherwise
specified by Seller, all prices are F.C.A. Seller's facility (INCOTERMS 2010). All sales are contingent
upon credit approval and payment for all purchases is due thirty (30) days from the date of invoice
(or such date as may be specified in the Quote). Unpaid invoices beyond the specified payment date
incur interest at the rate of 1.5% per month or the maximum allowable rate under applicable law.
4. Shipment; Delivery; Title and Risk of Loss. All delivery dates are approximate. Seller is not
responsible for damages resulting from any delay. Regardless of the manner of shipment, delivery
occurs and title and risk of loss or damage pass to Buyer, upon placement of the Products with the
shipment carrier at Seller's facility. Unless otherwise agreed, Seller may exercise its judgment in
choosing the carrier and means of delivery. No deferment of shipment at Buyers' request beyond the
respective indicated shipping date will be made except on terms that will indemnify, defend and hold
Seller harmless against all loss and additional expense. Buyer shall be responsible for any additional
shipping charges incurred by Seller due to Buyer’s acts or omissions.
5. Warranty. The warranty related to the Products is as follows: (i) Goods are warranted against
defects in material or workmanship for a period of twelve (12) months from the date of delivery or
2,000 hours of use, whichever occurs first; (ii) Services shall be performed in accordance with
generally accepted practices and using the degree of care and skill that is ordinarily exercised and
customary in the field to which the Services pertain and are warranted for a period of six (6) months
from the completion of the Services by Seller; and (iii) Software is only warranted to perform in
accordance with applicable specifications provided by Seller to Buyer for ninety (90) days from the
date of delivery or, when downloaded by a Buyer or end-user, from the date of the initial download.
All prices are based upon the exclusive limited warranty stated above, and upon the following
disclaimer:
DISCLAIMER OF WARRANTY: THIS WARRANTY IS THE SOLE AND ENTIRE WARRANTY
PERTAINING TO PRODUCTS. SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
AND IMPLIED, INCLUDING DESIGN, NONINFRINGEMENT, MERCHANTABILITY, AND FITNESS
FOR A PARTICULAR PURPOSE. SELLER DOES NOT WARRANT THAT THE SOFTWARE IS
ERROR-FREE OR FAULT-TOLERANT, OR THAT BUYER’S USE THEREOF WILL BE SECURE
OR UNINTERRUPTED. BUYER AGREES AND ACKNOWLEDGES THAT UNLESS OTHERWISE
AUTHORIZED IN WRITING BY SELLER THE SOFTWARE SHALL NOT BE USED IN
CONNECTION WITH HAZARDOUS OR HIGH RISK ACTIVITIES OR ENVIRONMENTS. EXCEPT
AS EXPRESSLY STATED HEREIN, ALL PRODUCTS ARE PROVIDED “AS IS”.
6. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon receipt.
No claims for shortages will be allowed unless reported to the Seller within ten (10) days of delivery.
Buyer shall notify Seller of any alleged breach of warranty within thirty (30) days after the date the
non-conformance is or should have been discovered by Buyer. Any claim or action against Seller
based upon breach of contract or any other theory, including tort, negligence, or otherwise must be
commenced within twelve (12) months from the date of the alleged breach or other alleged event,
without regard to the date of discovery.
7. LIMITATION OF LIABILITY. IN THE EVENT OF A BREACH OF WARRANTY, SELLER WILL,
AT ITS OPTION, REPAIR OR REPLACE THE NON-CONFORMING PRODUCT, RE-PERFORM
THE SERVICES, OR REFUND THE PURCHASE PRICE PAID WITHIN A REASONABLE PERIOD
OF TIME. IN NO EVENT IS SELLER LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT OF, THE SALE,
DELIVERY, NON-DELIVERY, SERVICING, NON-COMPLETION OF SERVICES, USE, LOSS OF
USE OF, OR INABILITY TO USE THE PRODUCTS OR ANY PART THEREOF, LOSS OF DATA,
IDENTITY, PRIVACY, OR CONFIDENTIALITY, OR FOR ANY CHARGES OR EXPENSES OF ANY
NATURE INCURRED WITHOUT SELLER'S WRITTEN CONSENT, WHETHER BASED IN
CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER'S LIABILITY
UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE PAID FOR THE
PRODUCTS.
8. Loss to Buyer's Property. Any designs, tools, patterns, materials, drawings, confidential
information or equipment furnished by Buyer or any other items which are or become Buyer's
property, will be considered obsolete and may be destroyed by Seller after two (2) consecutive years
have elapsed without Buyer ordering the Products manufactured using such property. Seller shall not
be responsible for any loss or damage to such property while it is in Seller's possession or control.
9. Special Tooling. Special Tooling includes but is not limited to tooling, jigs, fixtures and associated
manufacturing equipment acquired or necessary to manufacture Products. A tooling charge may be
imposed for any Special Tooling. Such Special Tooling shall be and remain Seller's property
notwithstanding payment of any charges by Buyer. In no event will Buyer acquire any interest in
Special Tooling belonging to Seller that is utilized in the manufacture of the Products, even if such
Special Tooling has been specially converted or adapted for such manufacture and notwithstanding
any charges paid by Buyer. Unless otherwise agreed, Seller has the right to alter, discard or otherwise
dispose of any Special Tooling or other property in its sole discretion at any time.
10. Security Interest. To secure payment of all sums due, Seller retains a security interest in all
Products delivered to Buyer and, Buyer’s acceptance of these Terms is deemed to be a Security
Agreement under the Uniform Commercial Code. Buyer authorizes Seller as its attorney to execute
and file on Buyer's behalf all documents Seller deems necessary to perfect its security interest.
11. User Responsibility. The Buyer through its own analysis and testing, is solely responsible for
making the final selection of the Products and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application of the Products are met. The Buyer
must analyze all aspects of the application and follow applicable industry standards, specifications,
and other technical information provided with the Product. If Seller provides Product options based
upon data or specifications provided by the Buyer, the Buyer is responsible for determining that such
data and specifications are suitable and sufficient for all applications and reasonably foreseeable
uses of the Products. In the event the Buyer is not the end-user, Buyer will ensure such end-user
complies with this paragraph.
12. Use of Products, Indemnity by Buyer. Buyer shall comply with all instructions, guides and
specifications provided by Seller with the Products. Unauthorized Uses. If Buyer uses or resells the
Products for any uses prohibited in Seller’s instructions, guides or specifications, or Buyer otherwise
fails to comply with Seller’s instructions, guides and specifications, Buyer acknowledges that any
such use, resale, or non-compliance is at Buyer's sole risk. Buyer shall indemnify, defend, and hold
Seller harmless from any losses, claims, liabilities, damages, lawsuits, judgments and costs
(including attorney fees and defense costs), whether for personal injury, property damage, intellectual
property infringement or any other claim, brought by or incurred by Buyer, Buyer’s employees, or any
other person, arising out of: (a) improper selection, application, design, specification or other misuse
of Products provided by Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s
use of patterns, tooling, equipment, plans, drawings, designs or specifications or other information or
things furnished by Buyer; (d) damage to the Products from an external cause, repair or attempted
repair by anyone other than Seller, failure to follow instructions, guides and specifications provided
by Seller, use with goods not provided by Seller, or opening, modifying, deconstructing or tampering
with the Products for any reason; or (e) Buyer’s failure to comply with these Terms. Seller shall not
indemnify Buyer under any circumstance except as otherwise provided in these Terms.
13. Cancellations and Changes. Buyer may not cancel or modify any order for any reason, except
with Seller's written consent and upon terms that will indemnify, defend and hold Seller harmless
against all direct, incidental and consequential loss or damage. Seller, at any time, may change
Product features, specifications, designs and availability.
14. Limitation on Assignment. Buyer may not assign its rights or obligations without the prior
written consent of Seller.
15. Force Majeure. Seller does not assume the risk and is not liable for delay or failure to perform
any of Seller’s obligations by reason of events or circumstances beyond its reasonable control
(“Events of Force Majeure”). Events of Force Majeure shall include without limitation: accidents,
strikes or labor disputes, acts of any government or government agency, acts of nature, delays or
failures in delivery from carriers or suppliers, shortages of materials, or any other cause beyond
Seller’s reasonable control.
16. Waiver and Severability. Failure to enforce any provision of these Terms will not invalidate that
provision; nor will any such failure prejudice Seller’s right to enforce that provision in the future.
Invalidation of any provision of these Terms by legislation or other rule of law shall not invalidate any
other provision herein and, the remaining provisions will remain in full force and effect.
17. Termination. Seller may terminate any agreement governed by or arising from these Terms for
any reason and at any time by giving Buyer thirty (30) days prior written notice. Seller may
immediately terminate, in writing, if Buyer: (a) breaches any provision of these Terms (b) appoints a
trustee, receiver or custodian for all or any part of Buyer’s property (c) files a petition for relief in
bankruptcy on its own behalf, or one if filed by a third party (d) makes an assignment for the benefit
of creditors; or (e) dissolves its business or liquidates all or a majority of its assets.
18. Ownership of Software. Seller retains ownership of all Software supplied to Buyer hereunder.
In no event shall Buyer obtain any greater right in and to the Software than a right in the nature of a
license limited to the use thereof and subject to compliance with any other terms provided with the
Software.
19. Indemnity for Infringement of Intellectual Property Rights. Seller is not liable for
infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar rights
(“Intellectual Property Rights”) except as provided in this Section. Seller will defend at its expense
and will pay the cost of any settlement or damages awarded in an action brought against Buyer based
on a third party claim that one or more of the Products sold hereunder infringes the Intellectual
Property Rights of a third party in the country of delivery of the Products by the Seller to the Buyer.
Seller's obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten
(10) days after Buyer becomes aware of any such claim, and Seller having sole control over the
defense of the claim including all negotiations for settlement or compromise. If one or more Products
sold hereunder is subject to such a claim, Seller may, at its sole expense and option, procure for
Buyer the right to continue using the Products, replace or modify the Products so as to render them
non-infringing, or offer to accept return of the Products and refund the purchase price less a
reasonable allowance for depreciation. Seller has no obligation or liability for any claim of
infringement: (i) arising from information provided by Buyer; or (ii) directed to any Products provided
hereunder for which the designs are specified in whole or part by Buyer; or (iii) resulting from the
modification, combination or use in a system of any Products provided hereunder. The foregoing
provisions of this Section constitute Seller's sole and exclusive liability and Buyer's sole and exclusive
remedy for such claims of infringement of Intellectual Property Rights.
20. Governing Law. These Terms and the sale and delivery of all Products are deemed to have
taken place in, and shall be governed and construed in accordance with, the laws of the State of
Ohio, as applicable to contracts executed and wholly performed therein and without regard to conflicts
of laws principles. Buyer irrevocably agrees and consents to the exclusive jurisdiction and venue of
the courts of Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising out of
or relating to the sale and delivery of the Products.
21. Entire Agreement. These Terms, along with the terms set forth in the main body of any Quote,
forms the entire agreement between the Buyer and Seller and constitutes the final, complete and
exclusive expression of the terms of sale. In the event of a conflict between any term set forth in the
main body of a Quote and these Terms, the terms set forth in the main body of the Quote shall prevail.
All prior or contemporaneous written or oral agreements or negotiations with respect to the subject
matter shall have no effect. These Terms may not be modified unless in writing and signed by an
authorized representative of Seller.
22. Compliance with Laws. Buyer agrees to comply with all applicable laws, regulations, and
industry and professional standards, including those of the United States of America, and the country
or countries in which Buyer may operate, including without limitation the U.S. Foreign Corrupt
Practices Act (“FCPA”), the U.S. Anti-Kickback Act (“Anti-Kickback Act”), U.S. and E.U. export control
and sanctions laws (“Export Laws”), the U.S. Food Drug and Cosmetic Act (“FDCA”), and the rules
and regulations promulgated by the U.S. Food and Drug Administration (“FDA”), each as currently
amended. Buyer agrees to indemnify, defend, and hold harmless Seller from the consequences of
any violation of such laws, regulations and standards by Buyer, its employees or agents. Buyer
acknowledges that it is familiar with all applicable provisions of the FCPA, the Anti-Kickback Act,
Export Laws, the FDCA and the FDA and certifies that Buyer will adhere to the requirements thereof
and not take any action that would make Seller violate such requirements. Buyer represents and
agrees that Buyer will not make any payment or give anything of value, directly or indirectly, to any
governmental official, foreign political party or official thereof, candidate for foreign political office, or
commercial entity or person, for any improper purpose, including the purpose of influencing such
person to purchase Products or otherwise benefit the business of Seller. Buyer further represents
and agrees that it will not receive, use, service, transfer or ship any Product from Seller in a manner
or for a purpose that violates Export Laws or would cause Seller to be in violation of Export Laws.
Parker Hannifin Corporation
Pneumatic Division
8676 E. M89
P.O. Box 901
Richland, MI 49083 USA
Tel: (269) 629-5000
Fax: (269) 629-5385
Customer/Technical Service
Tel: (269) 629-5575
Fax: (269) 629-5385
Web site: www.schraderbellows.com
E-mail: PDNMKTG@parker.com
Catalog VAL-SK-E/USA 4/04 IGS Printed in U.S.A.