Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T1
Section T
www.parker.com/pneu/lv
T
“LV” & “EZ” Series
Lockout Valves,
3-Way, 3-Port, 2-Position
LV” Series
Basic Features ......................................................T2
Applications ........................................................... T2
Mounting ............................................................... T2
Dimensions ........................................................... T2
“LV” Series Technical Information
Operation .............................................................. T3
Specifications ........................................................T3
Ordering Information .............................................T3
“EZ” Series
Basic Features ......................................................T4
Applications ........................................................... T4
Mounting
............................................................... T4
Dimensions ........................................................... T4
“EZ” Series Technical Information
Operation .............................................................. T5
Specifications ........................................................T5
Ordering Information .............................................T5
Flow & Safety Standards ...........................................T6
BOLD ITEMS ARE MOST POPULAR.
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T2
T
“LV” Series Valves
Applications & Dimensions
Catalog 0600P-10/USA
Basic Features
LV Series, 3/4" Exhaust Port Inches (mm)
A
7.67
(195)
B
5.49
(139)
C
5.92
(150)
D
1.25
(32)
E
1.22
(31)
F
3.08
(78)
G
4.22
(107)
H
2.25
(57)
J
1.44
(37)
K
0.74
(19)
L
2.00
(51)
Dimensions
J
L
D
B
F
C
E
G
A
K
H
Inlet
Outlet
Exhaust
.34 Dia. Thru
2 Places
1 2
3
Features
Used in systems for compliance with
OSHA Standard 29 CFR Part 1910
3/8 inch to 1-1/4 inch Pipe Sizes
Cv’s from 6.0 to 14
3/4 and 1-1/4 inch Exhaust Ports available
Rugged Cast Aluminum Alloy Body
Inline or Surface Mountable
Safety Yellow and Red for High Visibility
Detented Spool
Exhaust Port Threaded for Installation of
Silencer or Line for Remote Exhausting
Applications
Lockout valves are installed in pneumatic drop legs, or
individual pneumatic control lines (see Figure 1).
In accordance with OSHA procedures, lockout valves
are used during maintenance and service procedures
of pneumatically (air) operated equipment. Prior to
servicing, the red handle is pressed inward, blocking
pressure and relieving all downstream air pressure.
A padlock is installed through the locking hasp,
Preventing accidental actuation during the maintenance
procedure. Following maintenance, the padlock
is removed and the red handle is pulled outward,
returning air pressure to the system.
(For complete Lockout / Tagout procedures, consult
OSHA Standard 29 CFR Part 1910 in U.S. Federal
Register/Vol. 54 No. 169, Friday, September 1, 1989 /
Page 36644.)
Mounting
Valves can be inline mounted or surface mounted
using the two 11/32" mounting holes provided in the
valve body. Mount valves in plain view with the handle
oriented for accessibility.
“LV” Series
LV Series Valve shown with optional ES Series Silencer. For more
information refer to Flow Controls & Accessories Section.
10
12
1
3
2
LV Series, 1-1/4" Exhaust Port Inches (mm)
A
10.06
(256)
B
6.64
(169)
C
8.32
(211)
D
1.50
(38)
E
1.33
(34)
F
3.92
(100)
G
5.36
(136)
H
2.88
(73)
J
1.80
(46)
K
0.99
(25)
L
2.27
(58)
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T3
T
“LV” Series Valves
Operation, Specifications & Ordering
Catalog 0600P-10/USA
Technical Information
LV Series Model Number Index
Operation
Normal Machine Operation – Valve Open
With the handle pulled outward. Inlet Port 1 is open to
outlet Port 2. Exhaust Port 3 is blocked.
Specifications
Operating Pressure Range:
0 to 250 PSIG (0 to 1725 kPa)
Operating Temperature Range (Ambient):
32°F to 160°F (0°C to 71°C)
Lubrication:
For best results and service life, use clean, moisture
free, lubricated air.
Recommended Lubricant:
F442 Oil
Lockout Operation – Valve Closed
With the handle pushed inward. Inlet Port 1 is blocked.
Outlet Port 2 is open to Exhaust Port 3.
Materials of Construction
Body ............................................ Cast Aluminum Alloy
Handle ..........3/4" Exhaust Port - Cast Aluminum Alloy
1-1/4" Exhaust Port - Plastic
Spool ............................................................ Aluminum
Seals ..............................................Carboxylated Nitrile
Detent Spring ........................................Stainless Steel
Grease ....................................................Magnalube G
Trademark Magnalube
Port Size (Inlet & Outlet Ports 1 & 2)
3/8"* 3
1/2"* 4
3/4"*
6
1"
8
1-1/4"
A
* Available with 3/4" Exhaust Port.
Available with 1-1/4" Exhaust Port.
LV 6 N A B
Design Level
B Current
Port Size (Exhaust Port 3)
6 3/4"
A 1-1/4"
Thread Type (Ports 1, 2 & 3)
NPT N
BSPP (G) B
Open Closed
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T4
T
“EZ” Series Valves
Applications & Dimensions
Catalog 0600P-10/USA
Basic Features
Features
Combines Lockout and Soft-Start
Functions in a Single Unit
Used in systems for compliance with
OSHA Standard 29 CFR Part 1910
3/8 inch to 1-1/4 inch Pipe Sizes
Cv’s from 3.7 to 13.7
3/4 and 1-1/4 inch: Exhaust Ports available
Rugged Cast Aluminum Alloy Body
Exhaust Port Threaded for Installation of
Silencer or Line for Remote Exhausting
Inline or Surface Mountable
Applications
EZ valves are installed in pneumatic drop legs, or
individual pneumatic control lines (see Figure 1). In
accordance with OSHA procedures, EZ valves are
used during maintenance and service procedures
of pneumatically (air) operated equipment. Prior to
servicing, the blue handle is pressed inward, blocking
pressure and relieving all downstream air pressure.
A padlock is installed through the locking hasp,
preventing accidental actuation during the
maintenance procedure. Following maintenance,
the padlock is removed and the blue handle is pulled
outward, gradually returning air pressure to the
system. (For complete Lockout / Tagout procedures,
consult OSHA Standard 29 CFR Part 1910 in U.S.
Federal Register/Vol. 54 No. 169, Friday, September 1,
1989 / Page 36644.)
Mounting
Valves can be inline mounted or surface mounted
using the two 11/32" mounting holes provided in the
valve body. Mount valves in plain view with the handle
oriented for accessibility.
“EZ Series
L
K
J
G
H
D
F
E
Inlet
Outlet
Exhaust
B
C
A
.34 Dia. Thru
2 Places
1 2
3
Dimensions
EZ Series Valve shown with optional ES Series Silencer. For more
information refer to Flow Controls & Accessories Section.
10
12
1
3
2
EZ Series, 3/4" Exhaust Port Inches (mm)
A
6.26
(159)
B
5.78
(147)
C
6.25
(159)
D
2.20
(56)
E
1.10
(28)
F
2.97
(75)
G
4.36
(111)
H
1.32
(34)
J
1.44
(37)
K
0.80
(20)
L
2.02
(51)
EZ Series, 1-1/4" Exhaust Port Inches (mm)
A
7.32
(186)
B
6.63
(168)
C
7.63
(194)
D
2.74
(70)
E
1.37
(35)
F
3.95
(100)
G
5.50
(140)
H
1.74
(44)
J
1.92
(49)
K
1.00
(25)
L
2.26
(57)
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T5
T
Catalog 0600P-10/USA
Technical Information
“EZ” Series Valves
Operation, Specifications & Ordering
EZ Combination EEZ-On Series Model Number Index
Operation
Normal Machine Operation – Valve Open
When the blue handle is pulled outward, the adjustable
needle valve (accessed through the top of the handle)
setting determines the rate of pressure buildup. When
downstream pressure reaches the full flow described
in the specifications below, Inlet Port 1 is open to outlet
Port 2. Exhaust Port 3 is blocked.
Lockout Operation – Valve Closed
When the blue handle is pushed inward, the Inlet Port
1 is blocked. Downstream air is exhausted through
Exhaust Port 3.
Specifications
Operating Pressure Range:
30 to 150 PSIG (2 to 10 bar)
Open to Full Flow: Inlet Pressure - 25 PSIG (1.7 bar)
Operating Temperature Range (Ambient):
40°F to 175°F (4°C to 80°C)
Lubrication:
For best results and service life, use clean, moisture
free, lubricated air.
Recommended Lubricant:
F442 Oil
Materials of Construction
Body ............................................ Cast Aluminum Alloy
Handle ................................................................Plastic
Spool ............................................................ Aluminum
Seals ..............................................Carboxylated Nitrile
Detent Spring ........................................Stainless Steel
Grease ....................................................Magnalube G
Trademark Magnalube
Port Size (Inlet & Outlet Ports 1 & 2)
3/8"* 03
1/2"* 04
3/4"*
06
1"
08
1-1/4"
0A
* Available with 3/4" Exhaust Port.
Available with 1-1/4" Exhaust Port.
EZ 03 N B A
Design Level
B Current
Port Size (Exhaust Port 3)
6 3/4"
A 1-1/4"
Thread Type (Ports 1, 2 & 3)
NPT N
BSPP (G) B
BSPT (R) R
Open Open
Pressure Building Up Full Flow
Closed
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
T6
T
“LV” & “EZ” Series Valves
Flow & Safety Standards
Catalog 0600P-10/USA
Technical Information
FRL
Main Air
Pressure
To
Requirement
To
Requirement
10
12
1
3
2
10
12
1
3
2
Figure 1
Lockout Valves Shown In The
Passing Condition
Friday, September 1, 1989 the Occupational Safety
and Health Administration (OSHA) passed a standard,
29CFR Part 1910, requiring certain lockout and /
or tagout procedures for the control of a hazardous
energy source. This standard addresses practices and
procedures that are necessary to disable the release
of potentially hazardous energy while maintenance and
servicing activities are being performed. Tagout refers
to the use of tags to warn workers when equipment
using potentially hazardous energy is being serviced.
Lockout is the procedure which ensures that all power
to a piece of equipment is isolated, locked or blocked
and dissipated using a method that cannot be readily
removed to bypassed. Dissipation means stored energy
at the equipment is brought to a neutral state. This
standard is expected to save 120 lives and prevent
60,000 accidents a year. This OSHA Standard became
effective October 31, 1989.
Flow
Model 1 to 2 Cv 2 to 3 Cv
LV3N6B
6.00 8.00
LV4N6B
7.10 8.30
LV6N6B
8.60 9.50
LV6NAB
13.00 12.00
LV8NAB
13.00 14.00
LVANAB
20.00 14.00
Schematic
Model
1 to 2 Cv 2 to 3 Cv
EZ03NB6
3.79 3.78
EZ04NB6
5.31 3.77
EZ06NBA
6.01 9.25
EZ08NBA
11.18 8.13
EZ0ANBA
13.74 8.03
A typical application (Figure 1) shows a main lockout
valve mounted in the main drop leg, before the split to
machine functions. Additional lockout valves can be
used to isolate individual control lines. Before servicing,
the valve can be actuated and locked to isolate
downstream from pressure, and exhaust downstream
to atmosphere thus making equipment safe for
maintenance.
To reference this standard see the U.S. Federal
Register / Vol. 54, No. 169 / Friday, September 1, 1989
/ Page 36644. For copies of this standard, contact U.S.
Department of Labor, Occupational Safety and Health
Administration, Office of Publication, Room N3101,
Washington, DC 20210, (202) 523-9667.
1
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN
OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze all
aspects of your application including consequences of any failure, and review the information concerning the product or system
in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its autho-
rized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document
entitled “Offer of Sale”.
© Copyright 2007-1997, Parker Hannifin Corpor
ation. All Rights Reserved.
Global
Pneumatics
This icon can be found next to products that are widely
supported by Parker Pneumatics’ worldwide manufacturing
and sales network. When you see this icon, you can be
confident that this product is manufactured and / or stocked*
worldwide for rapid delivery. In addition to local manufacturing
or inventory, our sales network has been specifically trained on
these products to provide our customers with the best possible
service.
Products not showing this icon are still sold and distributed
worldwide. However, The Global Pneumatics icon represents
products that customers can expect the best level of support.
If you are a multi-national company, seek global sourcing or
ship globally, depend on Parker Pneumatic for PREMIER
CUSTOMER SERVICE.
* Stocking levels vary by country
Pneumatic Products
Catalog 0600P-10/USA
Global Pneumatics, Warning, Offer of Sale
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
Y10
Y
Safety Guide For Selecting And Using Pneumatic Division
Products And Related Accessories
WARNING:
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEMBLIES OR
RELATED ITEMS (“PRODUCTS”) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAMAGE. POSSIBLE
CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS INCLUDE
BUT ARE NOT LIMITED TO:
• Unintended or mistimed cycling or motion of machine members or failure to cycle
Work pieces or component parts being thrown off at high speeds.
• Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device.
• Explosion
• Suddenly moving or falling objects.
• Release of toxic or otherwise injurious liquids or gasses.
Before selecting or using any of these Products, it is important that you read and follow the instructions below.
!
Pneumatic Products
Warnings
Catalog 0600P-10/USA
Safety Guide
1. GENERAL INSTRUCTIONS
1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division
Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components.
1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all
systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons
or property.
1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see:
ISO 4414:1998, Pneumatic Fluid Power – General Rules Relating to Systems. See www.iso.org for ordering information.
1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs
or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this
safety guide as well as the specific Parker publications for the products considered or selected.
1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker
and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use
system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through
its own analysis and testing, is solely responsible for:
Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory.
Assuring that all user’s performance, endurance, maintenance, safety, and warning requirements are met and that the application
presents no health or safety hazards.
Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which
the valves, FRLs or Vacuum products are used; and,
Assuring compliance with all applicable government and industry standards.
1.6. Safety Devices: Safety devices should not be removed, or defeated.
1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured.
1.8. Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional
information. See the Parker publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com,
for telephone numbers of the appropriate technical service department.
2. PRODUCT SELECTION INSTRUCTIONS
2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system.
System components need to be able to provide adequate flow and pressure for the desired application.
2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the
instruction sheets supplied for maximum pressure ratings.
2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product
and result in complete product failure.
2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic
Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual
circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to
premature failure of a product.
2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of
synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the
factory or product literature for materials of construction.
2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures:
Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or
temperatures outside of the rated range.
Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols.
Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as
phosphate ester and di-ester lubricants.
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
Y11
Y
2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins
Tec-3, Tec-4, and Tec-5
2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage.
Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders.
Do not exceed the maximum primary pressure rating of any pressure regulator or any system component.
Consult product labeling or product literature for pressure rating limitations.
3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS
3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be
performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any
signs of nonconformance.
3.2. Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and
vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at
www.parker.com.
3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient
temperature can drop below freezing
4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS
4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced
without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience
with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or
replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must
be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10.
4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate
Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and
Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing
the Parker web site at www.parker.com.
4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more
information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout)
4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged
components:
Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an
indication of worn or damaged components.
Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation.
Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior.
Any observed improper system or component function: Immediately shut down the system and correct malfunction.
Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations.
Caution: Leak detection solutions should be rinsed off after use.
4.5. Routine Maintenance Issues:
Remove excessive dirt, grime and clutter from work areas.
Make sure all required guards and shields are in place.
4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate
properly and safely.
4.7. Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum
products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly
accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals
need to be established based on:
Previous performance experiences.
Government and / or industrial standards.
When failures could result in unacceptable down time, equipment damage or personal injury risk.
4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal
injury and property damage:
Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout
Tagout procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout).
Disconnect electrical supply (when necessary) before installation, servicing, or conversion.
Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service,
or conversion.
Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested
for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or
system into use.
Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local
representative for replacement labels.
4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions
supplied with the valve FRL or vacuum component to insure proper function of the system.
Pneumatic Products
Warnings
Catalog 0600P-10/USA
Safety Guide
Pneumatic Products
Catalog 0600P-10/USA
Offer of Sale
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
Y12
Y
The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries
and its authorized distributors, are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries
and its authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms
and Conditions. Buyer’s order for any such item, when communicated to Parker Hannifin Corporation, its subsidiaries or an authorized
distributor (“Seller”) verbally or in writing, shall constitute acceptance of this offer.
1. Terms and Conditions of Sale: All descriptions, quotations,
proposals, offers, acknowledgments, acceptances and sales of Seller’s
products are subject to and shall be governed exclusively by the terms
and conditions stated herein. Buyer’s acceptance of any offer to sell
is limited to these terms and conditions. Any terms or conditions in
addition to, or inconsistent with those stated herein, proposed by
Buyer in any acceptance of an offer by Seller, are hereby objected
to. No such additional, different or inconsistent terms and conditions
shall become part of the contract between Buyer and Seller unless
expressly accepted in writing by Seller. Seller’s acceptance of any offer
to purchase by Buyer is expressly conditional upon Buyer’s assent to all
the terms and conditions stated herein, including any terms in addition
to, or inconsistent with those contained in Buyer’s offer. Acceptance of
Seller’s products shall in all events constitute such assent.
2. Payment: Payment shall be made by Buyer net 30 days from the date
of delivery of the items purchased hereunder. Amounts not timely paid
shall bear interest at the maximum rate permitted by law for each month
or portion thereof that the Buyer is late in making payment. Any claims
by Buyer for omissions or shortages in a shipment shall be waived
unless Seller receives notice thereof within 30 days after Buyer’s receipt
of the shipment.
3. Delivery: Unless otherwise provided on the face hereof, delivery shall
be made F.O.B. Seller’s plant. Regardless of the method of delivery,
however, risk of loss shall pass to Buyer upon Seller’s delivery to a
carrier. Any delivery dates shown are approximate only and Seller shall
have no liability for any delays in delivery.
4. Warranty: Seller warrants that the items sold hereunder shall be free
from defects in material or workmanship for a period of 18 months from
date of shipment from Parker Hannifin Corporation. THIS WARRANTY
COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING
TO ITEMS PROVIDED HEREUNDER. SELLER MAKES NO OTHER
WARRANTY, GUARANTEE, OR REPRESENTATION OF ANY KIND
WHATSOEVER. ALL OTHER WARRANTIES, INCLUDING BUT NOT
LIMITED TO, MERCHANTABILITY AND FITNESS FOR PURPOSE,
WHETHER EXPRESS, IMPLIED, OR ARISING BY OPERATION OF
LAW, TRADE USAGE, OR COURSE OF DEALING ARE HEREBY
DISCLAIMED.
NOTWITHSTANDING THE FOREGOING, THERE ARE NO WARRANTIES
WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR
PARTIALLY, TO BUYER’S DESIGN OR SPECIFICATIONS.
5. Limitation of Remedy: SELLER’S LIABILITY ARISING FROM
OR IN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS
CONTRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR
REPLACEMENT OF THE ITEMS SOLD OR REFUND OF THE
PURCHASE PRICE PAID BY BUYER, AT SELLER’S SOLE OPTION.
IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND OR
NATURE WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOST
PROFITS ARISING FROM OR IN ANY WAY CONNECTED WITH THIS
AGREEMENT OR ITEMS SOLD HEREUNDER, WHETHER ALLEGED
TO ARISE FROM BREACH OF CONTRACT, EXPRESS OR IMPLIED
WARRANTY, OR IN TORT, INCLUDING WITHOUT LIMITATION,
NEGLIGENCE, FAILURE TO WARN OR STRICT LIABILITY.
6. Changes, Reschedules and Cancellations: Buyer may request to
modify the designs or specifications for the items sold hereunder as well
as the quantities and delivery dates thereof, or may request to cancel
all or part of this order, however, no such requested modification or
cancellation shall become part of the contract between Buyer and Seller
unless accepted by Seller in a written amendment to this Agreement.
Acceptance of any such requested modification or cancellation shall be
at Seller’s discretion, and shall be upon such terms and conditions as
Seller may require.
7. Special Tooling: A tooling charge may be imposed for any special
tooling, including without limitations, dies, fixtures, molds and patterns,
acquired to manufacture items sold pursuant to this contract. Such special
tooling shall be and remain Seller’s property notwithstanding payment
of any charges by Buyer. In no event will Buyer acquire any interest in
apparatus belonging to Seller which is utilized in the manufacture of
the items sold hereunder, even if such apparatus has been specially
converted or adapted for such manufacture and notwithstanding any
charges paid by Buyer. Unless otherwise agreed, Seller shall have the
right to alter, discard or otherwise dispose of any special tooling or other
property in its sole discretion at any time.
8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,
confidential information or equipment furnished by Buyer, or any other
items which become Buyer’s property, may be considered obsolete and
may be destroyed by Seller after two (2) consecutive years have elapsed
without Buyer placing an order for the items which are manufactured
using such property. Seller shall not be responsible for any loss or
damage to such property while it is in Seller’s possession or control.
9.
Taxes: Unless otherwise indicated on the face hereof, all prices and
charges are exclusive of excise, sales, use, property, occupational or like
taxes which may be imposed by any taxing authority upon the manufacture,
sale or delivery of the items sold hereunder. If any such taxes must be paid
by Seller or if Seller is liable for the collection of such tax, the amount
thereof shall be in addition to the amounts for the items sold. Buyer agrees
to pay all such taxes or to reimburse Seller therefore upon receipt of
its invoice. If Buyer claims exemption from any sales, use or other tax
imposed by any taxing authority, Buyer shall save Seller harmless from
and against any such tax, together with any interest or penalties thereon
which may be assessed if the items are held to be taxable.
10. Indemnity For Infringement of Intellectual Property Rights:
Seller shall have no liability for infringement of any patents, trademarks,
copyrights, trade dress, trade secrets or similar rights except as provided
in this Part 10. Seller will defend and indemnify Buyer against allegations
of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress
and trade secrets (hereinafter “Intellectual Property Rights”). Seller will
defend at its expense and will pay the cost of any settlement or damages
awarded in an action brought against Buyer based on an allegation that
an item sold pursuant to this contract infringes the Intellectual Property
Rights of a third party. Seller’s obligation to defend and indemnify Buyer
is contingent on Buyer notifying Seller within ten (10) days after Buyer
becomes aware of such allegations of infringement, and Seller having
sole control over the defense of any allegations or actions including all
negotiations for settlement or compromise. If an item sold hereunder is
subject to a claim that it infringes the Intellectual Property Rights of a
third party, Seller may, at its sole expense and option, procure for Buyer
the right to continue using said item, replace or modify said item so
as to make it noninfringing, or offer to accept return of said item and
return the purchase price less a reasonable allowance for depreciation.
Notwithstanding the foregoing, Seller shall have no liability for claims of
infringement based on information provided by Buyer, or directed to items
delivered hereunder for which the designs are specified in whole or part
by Buyer, or infringements resulting from the modification, combination
or use in a system of any item sold hereunder. The foregoing provisions
of this Part 10 shall constitute Seller’s sole and exclusive liability and
Buyer’s sole and exclusive remedy for infringement of Intellectual
Property Rights.
If a claim is based on information provided by Buyer or if the design for an
item delivered hereunder is specified in whole or in part by Buyer, Buyer
shall defend and indemnify Seller for all costs, expenses or judgements
resulting from any claim that such item infringes any patent, trademark,
copyright, trade dress, trade secret or any similar right.
11. Force Majeure: Seller does not assume the risk of and shall not be
liable for delay or failure to perform any of Seller’s obligations by reason
of circumstances beyond the reasonable control of Seller (hereinafter
“Events of Force Majeure”). Events of Force Majeure shall include without
limitation, accidents, acts of God, strikes or labor disputes, acts, laws,
rules or regulations of any government or government agency, fires,
floods, delays or failures in delivery of carriers or suppliers, shortages of
materials and any other cause beyond Seller’s control.
12. Entire Agreement/Governing Law: The terms and conditions set
forth herein, together with any amendments, modifications and any
different terms or conditions expressly accepted by Seller in writing,
shall constitute the entire Agreement concerning the items sold, and
there are no oral or other representations or agreements which pertain
thereto. This Agreement shall be governed in all respects by the law
of the State of Ohio. No actions arising out of sale of the items sold
hereunder or this Agreement may be brought by either party more than
two (2) years after the cause of action accrues.