Subject to change – 2013/04
6
Internet: www.festo.com/catalogue/...
Proportional directional control valves MPYE
Technical data
Electrical data
Pneumatic connection M5 Gx G¼ Gy
Low flow High flow
Power supply [V DC] 17 … 30
Max. current consumption in mid-position [mA] 100
at full stroke [mA] 1 100
Setpoint value Voltage type [V DC] 0…10
Current type [mA] 4…20
Max. hysteresis
1)
[%] 0.4
Valve mid-position Voltage type [V DC] 5(±0.1)
Current type [mA] 12 (±0.16)
Duty cycle
2)
[%] 100
Critical frequency
3)
[Hz] 125 100 100 90 65
Safety setting Active mid-position in the event of setpoint value cable break
Protection against polarity
reversal
Voltage type For all electrical connections
Current type For setpoint value
Protection class IP65
Electrical connection 4-pin plug socket, round design, M12x1
1) Referred to the maximum stroke of the piston spool.
2) The proportional direction control valve automatically switches off if it overheats (goes to mid-position) and switches back on once it cools down.
3) C orresponds to the 3dB frequency at the maximum movement stroke of the piston spool.
Operating and environmental c onditions
Operating pressure [bar] 0…10
Operating medium Compressed air in accordance with ISO 8573-1:2010 [6:4:4]
Note on operating/pilot medium Operation with lubricated medium not possible
Ambient temperature [°C] 0…50
Vibration resistance
1)
ToDIN/IEC68Parts2-6,severitylevel2
Continuous shock resistance
1)
ToDIN/IEC68Parts2-27,severitylevel2
CE symbol To 89/336/EEC (EMC regulation)
Temperature of medium [°C] 5 … 40, condensation not permitted
*
1) If the proportional directional control valve is in motion during operation, it must be mounted at right angles to the direction of movement.
Materials
Sectional view
1 2 3
1 Housing Anodised aluminium
2 Valve spool Tempered aluminium
3 Housing for electronics Galvanised acrylic butadiene styrene
– Seals Nitrile rubber