2014/10 – Subject to change
9
è Internet: www.festo.com/catalogue/...
Non-return valves HGL, piloted
Technical data – Push-in connector QS
Function
-M- Flow rate
130 … 1,400 l/min
-Q- Temperature range
–10 … +60 °C
-L- Operating pressure
0.5 … 10 bar
The piloted non-return valve is suit
able for short-duration positioning
and braking functions in pneumatic
drives.
Compressed air flows to and from the
drive as long as a pilot signal is
applied to pneumatic connection 21.
If no pilot signal is applied, the valve
shuts off the exhaust air from the drive
in flow direction 2 } 1 and the
movement of the drive is stopped.
Proven component suitable for use
in safety-related systems
Swivel connection can be swivelled
after mounting
Manual exhausting of air trapped in
the cylinder with manual override
HAB è 15 as an accessory
General technical data
Pneumatic connection 2 M5 Gx G¼ Gy G½
Pneumatic connection 1 QS-4 QS-4, QS-6 QS-8, QS-10 QS-8, QS-10 QS-12
Pilot air connection 21 QS-4 M5 Gx G¼ Gy
Valve function Piloted non-return function
Actuation type Pneumatic
Type of mounting Screw-in, via male thread
Mounting position Any
Nominal tightening torque [Nm] 1.25 ±10% 3.5 ±10% 11 ±10% 12.5 ±10% 14 ±10%
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
Operating and environmental conditions
Pneumatic connection 2 M5 Gx G¼ Gy G½
Operating pressure complete
temperature range
[bar] 0.5 … 10
Pilot pressure [bar] 2 … 10 1 … 10
Operating/pilot medium Compressed air in accordance with ISO 85731:2010 [7:4:4]
Note on operating/pilot medium Operation with lubricated medium possible (in which case lubricated operation will always be required)
Ambient temperature [°C] –10 … +60
Temperature of medium [°C] –10 … +60
Storage temperature [°C] –10 … +60
Corrosion resistance class CRC
1)
2
1) Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo
sphere typical for industrial applications.
-H- Note
Additional measures are required for
use in safety-related applications; in
Europe, for example, the standards
listed under the EC Machinery
Directive must be observed.
Without additional measures in
accordance with statutory minimum
requirements, the product is not suit
able for use in safety-related sections
of control systems.