Exhaust air flow control valves
Subject to change 2013/11
2
Internet: www.festo.com/catalogue/...
Exhaust air flow control valves
Produ ct range overview
Function
Exhaust air flow control valves are
screwed into the exhaust controls of
control valves or drives. They enable
the piston speed of cylinders or rotary
drives to be controlled by restricting
the air exhaust. This is done using the
adjusting element. The air is
exhausted via an integrated silencer
which reduces the noise level.
Design Valve function Design Type Pneumatic connection 1 qn
1)
Adjusting element Page/
Internet
[l/min]
Exhaust air
flow control
valve
Sintered metal
Flow control/
silencer function
GRE GÁ,G¼,Gy,G½ 0 3,600 Slottedheadscrew 3
Flow control/
silencer
Plastic
Flow control/
silencer function
VFFK M5, M7, Rx,R¼ 0…420 Knurled screw 5
GRU GÁ,G¼,Gy,G½,G¾ 0 8,000 Slottedheadscrew 8
1) Standard flow rate
2013/11 Subject to change
3
Internet: www.festo.com/catalogue/...
Exhaust air flow control valves GRE
Technical data
Function
-M- Flow rate
0 3,600 l/min
-Q- Temperature range
10…+7C
-L- Operating pressure
0…10bar
General technical data
Valve function Flow control/silencer function
Pneumatic connection 1 Gx G¼ Gy G½
Adjustment component Slottedheadscrew
Type of mounti ng Screw-in
Mounting position Any
Max. tightening torque [Nm] 15
Operating and environmental conditions
Pneumatic connection 1 Gx G¼ Gy G½
Operating pressure [bar] 0…10
Operating medium Compressed air in
accordance with
ISO 8573-1:2010 [7:–:–]
Compressed air in
accordance with
ISO 8573-1:2010 [7:–:–]
Compressed air in
accordance with
ISO 8573-1:2010 [7:4:4]
Compressed air in
accordance with
ISO 8573-1:2010 [7:–:–]
Note on operating/pilot medium Operation with lubricated medium possible (in which case lubricated operation will always be required)
Ambient temperature [°C] –10 +70
Temperature of medium [°C] –10 +70
Standard flow rate qn at 6 bar > 0 bar as a function of spindle rotations n
n
qn [l/min]
Subject to change 2013/11
4
Internet: www.festo.com/catalogue/...
Exhaust air flow control valves GRE
Technical data
Materials
Sectional view
Exhaust air flow control valve
1 Adjusting screw Brass
2 Threaded plug Wrought aluminium alloy
Seals NBR
Note on materials RoHS-compliant
Dimensions Download CAD data www.festo.com
Type Connection D1 L L1 ß
D
GRE-x Gx 15 28.5 6.5 14
GRE-¼ G¼ 18.2 34 8 17
GRE-y Gy 25 42 8 22
GRE-½ G½ 27 48 12 24
Ordering data
Pneumatic
connection 1
Standard nominal flow rate qnN
at 6 bar > 5bar
in direction of flow control
Standard flow rate qn
at 6 bar > 0bar
in direction of flow control
Weight Part No. Type
[l/min] [l/min] [g]
Gx 520 0…520 15 10351 GRE-x
G¼ 996 0…996 25 10352 GRE-¼
Gy 2,000 3 2,000 50 35310 GRE-y
G½ 3,600 0 3,600 75 10353 GRE-½
2
1
2013/11 Subject to change
5
Internet: www.festo.com/catalogue/...
Flow control/silencers VFFK
Type codes
VFFK
C K M7 P
Type
VFFK Flow control/silencer
Design
C Inline
Adjusting element
K Knurled screw
Pneumatic connection 1
M5 Thread M5
M7 Thread M7
R18 Thread Rx
R14 Thread R¼
Additional feature
P Polymer silencer
-V- New
Subject to change 2013/11
6
Internet: www.festo.com/catalogue/...
Flow control/silencers VFFK
Technical data
Functi on
-M- Flow rate
0 420 l/min
-Q- Temperature range
0…+6C
-L- Operating pressure
0…10bar
General technical data
Valve function Flow control/silencer function
Pneumatic connection 1 M5 M7 Rx R¼
Adjusting element Knurled screw
Type of mounti ng Screw-in
Mounting position Any
Type of seal on threaded plug Sealing ring Coating
Nominal tightening torque [Nm] 1.4 _20% 3.8 _20%
Operating and environmental conditions
Operating pressure [bar] 0…10
Operating medium Compressed air according to ISO 8573-1:2010 [7:4:4]
Note about the operating/pilot medium Lubricated operation possible
Ambient temperature [°C] 0…+60
Temperature of medium [°C] 0…+60
Storage temperature [°C] 0…+60
Materials
Type VFFK-C-K-M…-P VFFK-C-K-R…-P
Silencer insert PE
Threaded plug Nickel-plated brass
Regulating screw Nickel-plated brass
Knurled nut Aluminium
Seals NBR
Note on materials RoHS-compliant
Standard flow rate qn [l/min] as a function of turns of the adjusting screw n
VFFK-C-K-M5-P VFFK-C-K-M7-P
max
max
P1 = 1 bar
P1 = 3 bar
P1 = 5 bar
P1 = 7 bar
P1 = 9 bar
Flow rate tolerance: _20%
-V- New
2013/11 Subject to change
7
Internet: www.festo.com/catalogue/...
Flow control/silencers VFFK
Technical data
Standard flow rate qn [l/min] as a function of turns of the adjusting screw n
VFFK-C-K-R18-P VFFK-C-K-R14-P
max
max
P1 = 1 bar
P1 = 3 bar
P1 = 5 bar
P1 = 7 bar
P1 = 9 bar
Flow rate tolerance: _20%
Dimensions Download CAD data www.festo.com
VFFK-C-K-M…-P VFFK-C-K-R…-P
Type Connection D2 L1 L2 L3 ß 1
D1 min. max. min. max.
VFFK-C-K-M5-P M5x0.8 10 22.2 25.8 2.9 19.3 22.9 8
VFFK-C-K-M7-P M7x1 10 25 28.3 5.5 19.2 22.8 8
VFFK-C-K-R18-P Rx 14 29.1 35.8 8 25.1 31.8 10
VFFK-C-K-R14-P R¼ 18 31.1 37 10.8 25.1 31 14
Ordering data
Pneumatic
connection 1
Standard flow rate qn at 6 bar } 0bar Weight Part No. Type
[l/min] [g]
M5 0…80 4.5 133140 VFFK-C-K-M5-P
M7 0 100 6.1 133141 VFFK-C-K-M7-P
Rx 0 270 13.5 133142 VFFK-C-K-R18-P
R¼ 0 420 25 133143 VFFK-C-K-R14-P
-V- New
Subject to change 2013/11
8
Internet: www.festo.com/catalogue/...
Flow control/silencers GRU
Type codes
GRU
¼ B
Type
GRU Flow control/silencer
Pneumatic connection 1
x Thread Gx
¼ Thread G¼
Å Thread GÅ
½ Thread G½
¾ Thread G¾
Generation
B Bseries
2013/11 Subject to change
9
Internet: www.festo.com/catalogue/...
Flow control/silencers GRU
Technical data
Functi on
-M- Flow rate
0 8,000 l/min
-Q- Temperature range
10…+7C
-L- Operating pressure
0…10bar
General technical data
Valve function Flow control/silencer function
Pneumatic connection 1 Gx G¼ Gy G½ G¾
Adjustment component Slottedheadscrew
Type of mounti ng Screw-in
Mounting position Any
Operating and environmental conditions
Operating pressure [bar] 0…10
Operating medium Compressed air in accordance with ISO 8573-1:2010 [7:–:–]
Note on operating/pilot medium Operation with lubricated medium possible (in which case lubricated operation will always be required)
Ambient temperature [°C] –10 +70
Temperature of medium [°C] –10 +70
Standard flow rate qn at 6 bar > 0 bar as a function of spindle rotations n
qn [l/min]
n
Materials
Sectional view
Flow control/silencer
1 Adjusting screw PA
2 Housing, threaded plug Die-cast aluminium
Note on materials RoHS-compliant (GRU-y/GRU-¾ only)
2
1
Subject to change 2013/11
10
Internet: www.festo.com/catalogue/...
Flow control/silencers GRU
Technical data
Dimensions Download CAD data www.festo.com
1 Adjusting screw
Type Connection D1 L L1 ß
D
GRU-x Gx 16 46 5.4 14
GRU-¼ G¼ 19.5 63.3 6.4 17
GRU-y Gy 25 95.3 7.5 19
GRU-½ G½ 28 130 14 24
GRU-¾ G¾ 38 157 16 32
Ordering data
Pneumatic con-
nection 1
Standard nominal flow rate qnN
at 6 bar > 5bar
in direction of flow control
Standard flow rate qn
at 6 bar > 0bar
in direction of flow control
Weight Part No. Type
[l/min] [l/min] [g]
Gx 1,000 0 1,000 10 9516 GRU-x-B
G¼ 1,500 0 1,500 25 9517 GRU-¼-B
Gy 1,700 0 1,700 55 9518 GRU-y-B
G½ 4,000 0 4,000 100 9519 GRU-½-B
G¾ 8,000 0 8,000 170 9520 GRU-¾-B