Subject to change – 2013/11
6
Internet: www.festo.com/catalogue/...
Flow control/silencers VFFK
Technical data
Functi on
-M- Flow rate
0 … 420 l/min
-Q- Temperature range
0…+60°C
-L- Operating pressure
0…10bar
General technical data
Valve function Flow control/silencer function
Pneumatic connection 1 M5 M7 Rx R¼
Adjusting element Knurled screw
Type of mounti ng Screw-in
Mounting position Any
Type of seal on threaded plug Sealing ring Coating
Nominal tightening torque [Nm] 1.4 _20% 3.8 _20% –
Operating and environmental conditions
Operating pressure [bar] 0…10
Operating medium Compressed air according to ISO 8573-1:2010 [7:4:4]
Note about the operating/pilot medium Lubricated operation possible
Ambient temperature [°C] 0…+60
Temperature of medium [°C] 0…+60
Storage temperature [°C] 0…+60
Materials
Type VFFK-C-K-M…-P VFFK-C-K-R…-P
Silencer insert PE
Threaded plug Nickel-plated brass
Regulating screw Nickel-plated brass
Knurled nut Aluminium
Seals NBR –
Note on materials RoHS-compliant
Standard flow rate qn [l/min] as a function of turns of the adjusting screw n
VFFK-C-K-M5-P VFFK-C-K-M7-P
max
max
P1 = 1 bar
P1 = 3 bar
P1 = 5 bar
P1 = 7 bar
P1 = 9 bar
Flow rate tolerance: _20%
-V- New