1
Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent ► double solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
00134144
Version Spool valve, zero overlap
Sealing principle Soft sealing
Mounting on manifold strip P-strip, PRS strip
Working pressure min./max. See table below
Control pressure
min./max.
2 bar / 10 bar
Ambient temperature min./max. -25°C / +50°C
Medium temperature min./max. -25°C / +50°C
Medium Compressed air
Max. particle size 50 µm
Oil content of compressed air 0 mg/m³ - 1 mg/m³
Compressed air connection according to ISO 228-1
with directional pilot air exhaust
Connector standard EN 175301-803:2006
Degree of protectionWith connection See table below
Protected against polarity reversal
Compatibility index 13, 14
Duty cycle 100 %
Weight See table below
Materials:
Housing Die cast zinc; Polyamide, fiber-glass reinforced
Seals Acrylonitrile Butadiene Rubber
Technical Remarks
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter „Technical information“.
ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coils catalog page.
Operating voltage Voltage
tolerance
Power
consumption
Switch-on
power
Holding power
DC AC 50 Hz AC 60 Hz DC AC 50 Hz AC 60 Hz DC AC 50
Hz
AC 60
Hz
AC 50
Hz
AC 60
Hz
W VA VA VA VA
24 V - - -10% / +10% - - 2.1 - - - -
24 V - - -20% / +30% - - 4.5 - - - -
- 110 V 110 V - -20% / +10% -10% / +20% - 6.8 5.7 4.3 3.3
- 230 V 230 V - -20% / +10% -10% / +20% - 6.9 5.8 4.8 4.1
- 24 V 24 V - -20% / +10% -10% / +20% - 6.9 5.6 4.3 3.2
MO Compressed air connection Operating voltage Holding
power
Part No.
Input Output Exhaust Pilot
connec-
tion
Pilot
control
exhaust
DC AC 50
Hz
AC 60
Hz
AC 50
Hz
[VA]
G 1/4 G 1/4 G 1/4 - M5
24 V - - -
5776270220
24 V - - -
5776272220
- 110 V 110 V 4.3
5776275270
- 230 V 230 V 4.8
5776275280
- 24 V 24 V 4.3
5776275220
2
Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent ► double solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
MO Compressed air connection Operating voltage Holding
power
Part No.
Input Output Exhaust Pilot
connec-
tion
Pilot
control
exhaust
DC AC 50
Hz
AC 60
Hz
AC 50
Hz
[VA]
G 1/4 G 1/4 G 1/4 - M5 - - - -
5776275302
G 1/4 G 1/4 G 1/4 G 1/8 M5
24 V - - -
5776280220
- 110 V 110 V 4.3
5776285270
- 230 V 230 V 4.8
5776285280
G 1/4 G 1/4 G 1/4 G 1/8 M5 - - - -
5776285302
Part No. Hold-
ing
power
Switch-
on
power
Switch-
on
power
Power
con-
sumption
Flow rate value Working
pressure
min./max.
Switch-on
time
Switch-off
time
Pro-
tection
class
AC 60
Hz
AC 50 Hz AC 60 Hz 24 V DC Qn Qn
1▶2
Qn
2▶3
t
F
t
E
[VA] [VA] [VA] [W] [l/min] [bar] [ms] [ms]
5776270220
- - - 2.1
1200 1200 1200 2 / 10 21 21 IP 65
5776272220
- - - 4.5
5776275270
3.3 6.8 5.7 -
5776275280
4.1 6.9 5.8 -
5776275220
3.2 6.9 5.6 -
5776275302
- - - - 1200 1200 1200 2 / 10 - - -
5776280220
- - - 2.1
1200 1200 1200 -0.95 / 10 21 21 IP 65
5776285270
3.3 6.8 5.7 -
5776285280
4.1 6.9 5.8 -
5776285302
- - - - 1200 1200 1200 -0.95 / 10 - - -
Part No. Weight Note
[kg]
5776270220
0.75
1)
5776272220
1); 4)
5776275270
1)
5776275280
1)
5776275220
1)
5776275302
- 1); 3); 5)
5776280220
0.75 2)
5776285270
5776285280
5776285302
- 2); 3); 5)
HHB = Manual override
1) Pilot: internal
2) Pilot: External
3) Basic valve without coil
4) Higher power consumption
5) ATEX optional
Nominal flow Qn at 6 bar and Δp = 1 bar
3
Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent ► double solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
Dimensions
D577_628
1) only with separate pilot control G 1/8 2) after removal of cap M 5 internal thread M5 3) el. connector can
4) coil can be plugged at 45° intervals 5) manual override