Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent, without ► single solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
00134143
Version Spool valve, zero overlap
Sealing principle Soft sealing
Mounting on manifold strip P-strip, PRS strip
Working pressure min./max. See table below
Control pressure
min./max.
3 bar / 10 bar
Ambient temperature min./max. See table below
Medium temperature min./max. See table below
Medium Compressed air
Max. particle size 50 µm
Oil content of compressed air 0 mg/m³ - 1 mg/m³
Compressed air connection according to ISO 228-1
with directional pilot air exhaust
Connector standard EN 175301-803:2006
Degree of protectionWith connection See table below
Protected against polarity reversal
Compatibility index See table below
Duty cycle 100 %
Weight See table below
Materials:
Housing Die cast zinc; Polyamide, fiber-glass reinforced
Seals Acrylonitrile Butadiene Rubber
Technical Remarks
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter „Technical information“.
ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coils catalog page.
Operating voltage Voltage
tolerance
Power
consumption
Switch-on
power
Holding power
DC AC 50 Hz AC 60 Hz DC AC 50 Hz AC 60 Hz DC AC 50
Hz
AC 60
Hz
AC 50
Hz
AC 60
Hz
W VA VA VA VA
24 V - - -10% / +15% - - 2.1 - - - -
- 230 V 230 V - -20% / +10% -10% / +20% - 6.9 5.8 4.8 4.1
24 V - - -10% / +10% - - 2.1 - - - -
96 V - - -30% / +30% - - 5.8 - - - -
- 110 V 110 V - -20% / +10% -10% / +20% - 6.8 5.7 4.3 3.3
MO Compressed air connection Operating voltage Holding
power
Part No.
Input Output Exhaust Pilot
connec-
tion
Pilot
control
exhaust
DC AC 50
Hz
AC 60
Hz
AC 50
Hz
[VA]
G 1/4 G 1/4 G 1/4 - M5
24 V - - -
5776070220
- 230 V 230 V 4.8
5776075280
G 1/4 G 1/4 G 1/4 G 1/8 M5
24 V - - -
5776080220
- 230 V 230 V 4.8
5776085280
2
Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent, without ► single solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
MO Compressed air connection Operating voltage Holding
power
Part No.
Input Output Exhaust Pilot
connec-
tion
Pilot
control
exhaust
DC AC 50
Hz
AC 60
Hz
AC 50
Hz
[VA]
G 1/4 G 1/4 G 1/4 - M5 - - - -
5776075302
G 1/4 G 1/4 G 1/4 G 1/8 M5 - - - -
5776085302
G 1/4 G 1/4 G 1/4 - M5
24 V
- - -
R412004093
96 V
5776070360
G 1/4 G 1/4 G 1/4 G 1/8 M5 - 110 V 110 V 4.3
5776085270
G 1/4 G 1/4 G 1/4 - M5 24 V - - -
5776970220
- G 1/4 G 1/4 G 1/4 - M5 24 V - - -
5776980220
Part No. Holding
power
Switch-on
power
Switch-on
power
Power
consump-
tion
Flow rate value Working
pressure
min./max.
Ambient
temperature
min./max.
Medium
temperature
min./max.
AC 60
Hz
AC 50 Hz AC 60 Hz 24 V DC Qn Qn
1▶2
Qn
2▶3
[VA] [VA] [VA] [W] [l/min] [bar] [°C] [°C]
5776070220
- - - 2.1
1200 1200 1200 3 / 10 -25°C / +50°C -25°C / +50°C
5776075280
4.1 6.9 5.8 -
5776080220
- - - 2.1
1200 1200 1200 -0.95 / 10 -25°C / +50°C -25°C / +50°C
5776085280
4.1 6.9 5.8 -
5776075302
- - - - 1200 1200 1200 3 / 10 -25°C / +50°C -25°C / +50°C
5776085302
- - - - 1200 1200 1200 -0.95 / 10 -25°C / +50°C -25°C / +50°C
R412004093
- - -
2.1
1200 1200 1200 3 / 10
-10°C / +50°C -10°C / +50°C
5776070360
5.8 -25°C / +50°C -25°C / +50°C
5776085270
3.3 6.8 5.7 - 1200 1200 1200 -0.95 / 10 -25°C / +50°C -25°C / +50°C
5776970220
- - - 2.1 1200 1200 1200 3 / 10 -25°C / +50°C -25°C / +50°C
5776980220
- - - 2.1 1200 1200 1200 3 / 10 -25°C / +50°C -25°C / +50°C
Part No. Switch-on time Switch-off time Compatibility index Protection
class
Weight Note
t
F
t
E
[ms] [ms] [kg]
5776070220
25 45 13, 14 IP 65 0.57 2)
5776075280
5776080220
25 45 13, 14 IP 65 0.57 3)
5776085280
5776075302
- - 13, 14 - - 2); 4); 5)
5776085302
- - 13, 14 - - 3); 4); 5)
HHB = Manual override
1) Nickel-plated armature guide (only suitable for DC variant), i.e. the base must not be equipped with AC coils.
2) Pilot: internal
3) Pilot: External
4) Basic valve without coil
5) ATEX optional
6) ATEX certified
Nominal flow Qn at 6 bar and Δp = 1 bar
3
Directional valves ► Electrically operated
5/2-directional valve, Series CD07
► Qn = 1200 l/min ► Pilot valve width: 30 mm ► pipe connection ► compressed air connection output: G 1/4
► Electr. connection: Plug, EN 175301-803, form A ► Manual override: with detent, without ► single solenoid
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informa-
tion
Pneumatics catalog, online PDF, as of 2014-06-10, ©AVENTICS S.a.r.l., subject to change
Part No. Switch-on time Switch-off time Compatibility index Protection
class
Weight Note
t
F
t
E
[ms] [ms] [kg]
R412004093
25 45
13, 14
IP 65 0.57
2); 6)
5776070360
14 2)
5776085270
25 45 14 IP 65 0.57 3)
5776970220
25 45 14, 14 IP 65 0.57 1); 2)
5776980220
25 45 14 IP 65 0.57 2)
HHB = Manual override
1) Nickel-plated armature guide (only suitable for DC variant), i.e. the base must not be equipped with AC coils.
2) Pilot: internal
3) Pilot: External
4) Basic valve without coil
5) ATEX optional
6) ATEX certified
Nominal flow Qn at 6 bar and Δp = 1 bar
Dimensions
D577_608
1) only with separate pilot control G 1/8 2) after removal of cap M 5 internal thread M5 3) el. connector can
4) coil can be plugged at 45° intervals 5) manual override