Series PM1
AVENTICS™ Series PM1
Page 1
2022-03-08
Pressure Switches, Series PM1
R412010730
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
1 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412010730
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412010730
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412010730
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) Tightening torque MA = 12 + 1 Nm
AVENTICS
Pressure Switches, Series PM1
R412010730
Page 4
2022-03-08
differential switching pressure
characteristic curve (-0,9 – 1 bar)
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412010731
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412010731
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412010731
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412010731
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) Tightening torque MA = 12 + 1 Nm
AVENTICS
Pressure Switches, Series PM1
R412010731
Page 4
2022-03-08
differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412024680
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
1 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412024680
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.65 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412024680
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412024680
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) Tightening torque MA = 12 + 1 Nm
AVENTICS
Pressure Switches, Series PM1
R412024680
Page 4
2022-03-08
differential switching pressure
characteristic curve (-0,9 – 1 bar)
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412024681
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412024681
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.65 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412024681
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412024681
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) Tightening torque MA = 12 + 1 Nm
AVENTICS
Pressure Switches, Series PM1
R412024681
Page 4
2022-03-08
differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412010732
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412010732
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412010732
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412010732
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) O-ring Ø5x1,5 (included)
3) cylinder screw M5x30 (included in scope of delivery)
AVENTICS
Pressure Switches, Series PM1
R412010732
Page 4
2022-03-08
differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412024682
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412024682
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.65 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412024682
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412024682
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) O-ring Ø5x1,5 (included)
3) cylinder screw M5x30 (included in scope of delivery)
AVENTICS
Pressure Switches, Series PM1
R412024682
Page 4
2022-03-08
differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412024760
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
1 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412024760
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412024760
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412024760
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) O-ring Ø5x1,5 (included)
3) cylinder screw M5x30 (included in scope of delivery)
AVENTICS
Pressure Switches, Series PM1
R412024760
Page 4
2022-03-08
differential switching pressure
characteristic curve (-0,9 – 1 bar)
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-08
Pressure Switches, Series PM1
R412024761
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
1 bar
Protection against overpressure
60 bar
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
Hydraulic oil
Certificates
ATEX
AVENTICS
Pressure Switches, Series PM1
R412024761
Page 2
2022-03-08
Electrical connection 2, type
open cable ends
ATEX ID
Ex II 3G ec nC IIC T4 Gc
Ex II 3D tc IIIC T135° Dc
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.65 kg
Material
Housing material
Aluminum
Seal material
Nitrile butadiene rubber
Material electrical connection
Copper/brass
Part No.
R412024761
Technical information
PM1 series pressure switches are suitable for measuring the pressure or vacuum of air and
hydraulic oil.
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure range is set via the adjustment screw.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure Switches, Series PM1
R412024761
Page 3
2022-03-08
Dimensions in mm
1) Adjustment screw, self-holding
2) O-ring Ø5x1,5 (included)
3) cylinder screw M5x30 (included in scope of delivery)
AVENTICS
Pressure Switches, Series PM1
R412024761
Page 4
2022-03-08
differential switching pressure
characteristic curve (-0,9 – 1 bar)
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010711
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
0 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010711
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
With valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010711
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010711
Page 3
2022-03-29
Dimensions in mm
1) Valve plug connector
2) Mounting screw
3) sealing surface
4) Tightening torque MA = 12 + 1 Nm
5) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010711
Page 4
2022-03-29
Differential switching pressure
characteristic curve (-0,9 – 0 bar)
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Pressure sensor, Series PM1
R412010711
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1.2
60 5 0.8
125 5 0.4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412022752
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
3 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412022752
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
Without valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412022752
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412022752
Page 3
2022-03-29
Dimensions in mm
1) Valve plug connector
2) Mounting screw
3) sealing surface
4) Tightening torque MA = 12 + 1 Nm
5) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412022752
Page 4
2022-03-29
Differential switching pressure
characteristic curve (-0.9 – 3 bar)
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1,2
60 5 0,8
125 5 0,4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Pressure sensor, Series PM1
R412022752
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Page 1
2022-03-28
Pressure sensor, Series PM1
R412010712
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010712
Page 2
2022-03-28
Medium
Compressed air
Hydraulic oil
Valve plug connector
Without valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010712
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010712
Page 3
2022-03-28
Dimensions in mm
1) Mounting screw
2) sealing surface
3) Tightening torque MA = 12 + 1 Nm
4) adjustment screw
AVENTICS
Pressure sensor, Series PM1
R412010712
Page 4
2022-03-28
Differential switching pressure
characteristic curve (0,2 - 16 bar)
A) p1 (-), min.
B) p1 (-), max.
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8
bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1.2
60 5 0.8
125 5 0.4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Pressure sensor, Series PM1
R412010712
Page 5
2022-03-28
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010713
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010713
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
With valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010713
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010713
Page 3
2022-03-29
Dimensions in mm
1) Valve plug connector
2) Mounting screw
3) sealing surface
4) Tightening torque MA = 12 + 1 Nm
5) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010713
Page 4
2022-03-29
Differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Pressure sensor, Series PM1
R412010713
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1,2
60 5 0,8
125 5 0,4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010714
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
0 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010714
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
With valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.13 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010714
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010714
Page 3
2022-03-29
Dimensions in mm
1) Valve plug connector
2) Mounting screw
3) cylinder screw M5x30 (included in scope of delivery)
4) O-ring Ø5x1,5 (included)
5) O-ring countersink
6) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010714
Page 4
2022-03-29
Differential switching pressure
characteristic curve (-0,9 – 0 bar)
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1.2
60 5 0.8
125 5 0.4
250 5
tablefooter
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Pressure sensor, Series PM1
R412010714
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
tablefooter
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010715
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010715
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
Without valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010715
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010715
Page 3
2022-03-29
Dimensions in mm
1) Mounting screw
2) cylinder screw M5x30 (included in scope of delivery)
3) O-ring Ø5x1,5 (included)
4) O-ring countersink
5) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010715
Page 4
2022-03-29
Differential switching pressure
characteristic curve (0,2 - 16 bar)
A) p1 (-), min.
B) p1 (-), max.
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8
bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1.2
60 5 0.8
125 5 0.4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Pressure sensor, Series PM1
R412010715
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010718
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010718
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Valve plug connector
With valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.13 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010718
Technical information
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010718
Page 3
2022-03-29
Dimensions in mm
1) Valve plug connector
2) Mounting screw
3) cylinder screw M5x30 (included in scope of delivery)
4) O-ring Ø5x1,5 (included)
5) O-ring countersink
6) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010718
Page 4
2022-03-29
Differential switching pressure
characteristic curve (0,2 - 16 bar)
A) p1 (-), min.
B) p1 (-), max.
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8
bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.05
250 3
tablefooter
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Pressure sensor, Series PM1
R412010718
Page 5
2022-03-29
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1.2
60 5 0.8
125 5 0.4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-28
Pressure sensor, Series PM1
R412010716
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
0 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010716
Page 2
2022-03-28
Medium
Compressed air
Hydraulic oil
Electrical connection 2, type
Plug
Electrical connection 2, thread size
M12x1
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP67
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010716
Technical information
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010716
Page 3
2022-03-28
Dimensions in mm
1) M12 connection rotatable by 90° and 30° with detent
2) sealing surface
3) Mounting screw
4) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010716
Page 4
2022-03-28
Differential switching pressure
characteristic curve (-0,9 – 0 bar)
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Pin assignments
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 No function
4 NO (make contact)
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 4 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-28
Pressure sensor, Series PM1
R412010717
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Internal thread
Compressed air connection
G 1/4
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010717
Page 2
2022-03-28
Medium
Compressed air
Hydraulic oil
Electrical connection 2, type
Plug
Electrical connection 2, thread size
M12x1
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP67
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010717
Technical information
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010717
Page 3
2022-03-28
Dimensions in mm
1) M12 connection rotatable by 90° and 30° with detent
2) sealing surface
3) Tightening torque MA = 12 + 1 Nm
4) adjustment screw
AVENTICS
Pressure sensor, Series PM1
R412010717
Page 4
2022-03-28
Differential switching pressure
characteristic curve (0,2 - 16 bar)
A) p1 (-), min.
B) p1 (-), max.
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8
bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar
Pin assignments
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 No function
4 NO (make contact)
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30-250 3 -
30 / 48 / 60 / 125 - 2 / 0,55 / 0,4 / 0,05
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30-250 3 -
30 / 48 / 60 / 125 - 3 / 1,2 / 0,8 / 0,4
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010719
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
-0.9 bar
Operating pressure max
0 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010719
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Electrical connection 2, type
Plug
Electrical connection 2, thread size
M12x1
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP67
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010719
Technical information
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010719
Page 3
2022-03-29
Dimensions in mm
1) M12 connection rotatable by 90° and 30° with detent
2) cylinder screw M5x30 (included in scope of delivery)
3) O-ring Ø5x1,5 (included)
4) O-ring countersink
5) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010719
Page 4
2022-03-29
Differential switching pressure
characteristic curve (-0,9 – 0 bar)
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Pin assignments
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 No function
4 NO (make contact)
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 4 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-29
Pressure sensor, Series PM1
R412010720
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection type
Flange with O-ring
Compressed air connection
Ø 5x1,5
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
AVENTICS
Pressure sensor, Series PM1
R412010720
Page 2
2022-03-29
Medium
Compressed air
Hydraulic oil
Electrical connection 2, type
Plug
Electrical connection 2, thread size
M12x1
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP67
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010720
Technical information
Switching function increasing pressure: contact switches from 1-2 to 1-3. Switching function
decreasing pressure: contact switches from 1-3 to 1-2.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010720
Page 3
2022-03-29
Dimensions in mm
1) M12 connection rotatable by 90° and 30° with detent
2) cylinder screw M5x30 (included in scope of delivery)
3) O-ring Ø5x1,5 (included)
4) O-ring countersink
5) adjustment screw
AVENTICS
Pressure sensor, Series PM1
R412010720
Page 4
2022-03-29
Differential switching pressure
characteristic curve (0,2 - 16 bar)
A) p1 (-), min.
B) p1 (-), max.
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8
bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar
Pin assignments
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 No function
4 NO (make contact)
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 4 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Page 1
2022-03-28
Pressure sensor, Series PM1
R412010721
General series information
Series PM1
The AVENTICS Series PM1 is a compact
pressure switch for measuring compressed
air and hydraulic oil. The Series PM1 allows
users to select between different pressure
ranges from -0.9 to 16 bar.
Technical information
Industry
Industrial
Type
Mechanical
Type
Diaphragm, spring loaded, adjustable
Mounting orientation
Any
Operating pressure min
0.2 bar
Operating pressure max
16 bar
Protection against overpressure
80 bar
Operational voltage
24 V DC
24 V DC
Shock resistance max.
15 g IEC 60068 - 2-64
Vibration resistance
10 g (60 - 500 Hz) IEC 60068 - 2-6
Precision (% of full scale value)
± 2 %
Hysteresis
max. switching pressure difference
Measurement
Relative pressure
Compressed air connection
CNOMO
Min. medium temperature
-10 °C
Max. medium temperature
80 °C
Medium
Compressed air
AVENTICS
Pressure sensor, Series PM1
R412010721
Page 2
2022-03-28
Hydraulic oil
Valve plug connector
Without valve plug connector
Electrical connection 2, type
Plug
Electrical connection 2, thread size
EN 175301-803, form A
Min. ambient temperature
-20 °C
Max. ambient temperature
80 °C
Switching element
microswitch (input/output)
Max. switching frequency
100/min.
Switching point
adjustable
Protection class
IP65
Mounting types
via through holes
Weight
0.37 kg
Material
Housing material
Aluminum
Seal material
Acrylonitrile butadiene rubber
Material electrical connection
Brass
Part No.
R412010721
Technical information
Switching function in case of rising underpressure: contact switches from 1-3 to 1-2. Switching
function in case of falling underpressure: contact switches from 1-2 to 1-3.
Set to 1,5 bar operating pressure. Adjustment screw secured and covered by an adhesive label.
Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped
with appropriate spark-quenching!
The microswitch has silver-plated contacts.
Please observe the pin assignment when selecting plug connectors.
Min. switching pressure range 0.2 bar falling/0.5 bar rising
The pressure dew point must be at least 15 °C under ambient and medium temperature and may
not exceed 3 °C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the “Technical
information” document (available in https://www.emerson.com/en-us/support).
AVENTICS
Pressure sensor, Series PM1
R412010721
Page 3
2022-03-28
Dimensions in mm
1) Mounting screw
2) Adjustment screw, self-holding
AVENTICS
Pressure sensor, Series PM1
R412010721
Page 4
2022-03-28
Differential switching pressure
characteristic curve (0,2 - 16 bar)
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
1) Rising
2) Falling
PIN assignment for valve plug
connectors
Pin assignments
Pin Allocation
1 +UB
2 break contact
3 NO (make contact)
4 GND
Max. permissible continuous current I
max. [A] with ohmic load
U [V] I [A] 1) I [A] 2)
30 5 3
48 5 1,2
60 5 0,8
125 5 0,4
250 5
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
AVENTICS
Pressure sensor, Series PM1
R412010721
Page 5
2022-03-28
Max. permissible continuous current I
max. [A] with inductive load
U [V] I [A] 1) 3) I [A] 2) 4)
30 3 2
48 3 0.55
60 3 0.4
125 3 0.15
250 3
reference cycle: 30/min., reference temperature: +30 °C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
AVENTICS
Efficient pneumatic solutions, our program:
cylinders and drives, valves and valve systems,
air supply management
Visit us: Emerson.com/Aventics
Your local contact: Emerson.com/contactus
Emerson.com
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/Emerson-Automation-Solutions
Twitter.com/EMR_Automation
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. This
Document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS GmbH. It may not be
reproduced or given to third parties without its consent. Only use the AVENTICS products shown in industrial applications. Read the product
documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When
integrating the product into applications, note the system manufacturer’s specifications for safe use of the product. The data specified only serve
todescribe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information.
The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are
subject to a natural process of wear and aging.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand logotype are registered trademarks of one
of the Emerson family of companies. All other marks are the property of their respective owners. © 2017 Emerson Electric Co.
All rights reserved.
2019-03