Page 1 |
AVENTICS
Pressure regulator, Series MU1-RGS
- G 2
- Qn = 50000 l/min
- Standard pressure regulator
- Activation pneumatically
- suitable for ATEX
Parts Pressure regulator
Mounting orientation Any
Certificates suitable for ATEX
Working pressure min./max. 0,5 ... 25 bar
Control pressure min./max. 16 bar
Ambient temperature min./max. -10 ... 80 °C
Medium temperature min./max. -10 ... 80 °C
Medium Compressed air Neutral gases
Regulator type Diaphragm-type pressure regulator
Regulator function withrelieving air exhaust
Adjustment range min./max. 0,5 ... 16 bar
Pressure supply single
Activation pneumatically
Weight 4,68 kg
Technical data
Part No. Port
Flow
Qn
R412006578 G 2 50000 l/min
Nominal flow Qn with secondary pressure p2 = 6 bar at Δp = 1 bar, Suitable for use in Ex zones 1, 2, 21, 22.
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .
Mounting type: for installing in piping
Suitable for use in Ex zones 1, 2, 21, 22.
Technical information
Technical information
Material
Housing Die-cast aluminum
Seals Acrylonitrile butadiene rubber
Page 2 |
AVENTICS
Dimensions
Dimensions
1) Pilot connection
2) Pressure gauge connection P1
3) Pressure gauge connection P2
Dimensions
A1 A2 A4 B ±5 C ±5 D ±5 E ±7 J ±5 L T1 T2 T4
G 2 G2 G 1/4 160 90 107 197 160 G 1/4 30 30 9.5
PDF creation date: 01.12.2020
Page 3 |
AVENTICS
Diagrams
Pressure characteristics curve
p1 = working pressure
p2 = secondary pressure
q = flow rate
* starting point
PDF creation date: 01.12.2020
Page 4 |
AVENTICS
Diagrams
Flow rate characteristic (secondary range p2: 0.5 - 10 bar)
p1 = Working pressure
p2 = Secondary pressure
qn = Nominal flow
PDF creation date: 01.12.2020
Page 5 |
AVENTICS
Circuit diagram
Application example
1) precision pressure regulator
2) pressure regulator valve, pneumatically operated
PDF creation date: 01.12.2020
Efficient pneumatic solutions, our program:
cylinders and drives, valves and valve systems,
air supply management
Visit us: Emerson.com/Aventics
Your local contact: Emerson.com/contactus
Emerson.com
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/Emerson-Automation-Solutions
Twitter.com/EMR_Automation
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. This
Document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS GmbH. It may not be
reproduced or given to third parties without its consent. Only use the AVENTICS products shown in industrial applications. Read the product
documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When
integrating the product into applications, note the system manufacturer's specifications for safe use of the product. The data specified only serve to
describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information.
The information given does not release the user from the obligation of own judgement and verification. It must be remembered that the products are
subject to a natural process of wear and aging.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand logotype are registered trademarks of one
of the Emerson family of companies. All other marks are the property of their respective owners. © 2020 Emerson Electric Co.
All rights reserved.
2020-12