Page 1 |
AVENTICS
Standard oil-mist lubricator, Series
MU1-LBS
- G 2
- Nominal flow Qn 25000 l/min
- suitable for ATEX
Type Oil-mist lubricator
Parts Standard oil-mist lubricator
Mounting orientation vertical
Certificates suitable for ATEX
Compressed air connection G 2
Working pressure min./max. 0,5 ... 16 bar
Ambient temperature min./max. -10 ... 60 °C
Medium temperature min./max. -10 ... 60 °C
Medium Compressed air Neutral gases
Lubricator reservoir volume 1700 cm³
Type of filling Manual oil filling
Weight 3,37 kg
Technical data
Part No. Port Nominal flow Qn Material Reservoir Protective guard
R412006581 G 2 25000 l/min Polycarbonate Steel
Suitable for use in Ex zones 1, 2, 21, 22., Nominal flow with secondary pressure 6.3 bar at Δp = 1 bar
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .
Mounting via 2 through-holes in housing
Manual oil filling possible during operation.
Suitable for use in Ex zones 1, 2, 21, 22.
Oil dosing at 1000 l/min 1-2 drops
Technical information
Technical information
Material
Housing Die-cast aluminum
Seals Acrylonitrile butadiene rubber
Reservoir Polycarbonate
Protective guard Steel
Page 2 |
AVENTICS
Dimensions
Dimensions
Dimensions
A1 A2 B ±7 D ±7 E ±7 H I J1 J3 T2 V ±5 W ±7
G 2 G 2 150 383 436 120 10.5 130 50 24 41 459
PDF creation date: 01.12.2020
Page 3 |
AVENTICS
Diagrams
Flow rate characteristic
p1 = working pressure
qn = nominal flow
PDF creation date: 01.12.2020
Page 4 |
AVENTICS
Diagrams
minimum flow rate curve (flow rate necessary for the correct functioning of the lubricator)
p1 = working pressure
qn = nominal flow
PDF creation date: 01.12.2020
Efficient pneumatic solutions, our program:
cylinders and drives, valves and valve systems,
air supply management
Visit us: Emerson.com/Aventics
Your local contact: Emerson.com/contactus
Emerson.com
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/Emerson-Automation-Solutions
Twitter.com/EMR_Automation
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. This
Document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS GmbH. It may not be
reproduced or given to third parties without its consent. Only use the AVENTICS products shown in industrial applications. Read the product
documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When
integrating the product into applications, note the system manufacturer's specifications for safe use of the product. The data specified only serve to
describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information.
The information given does not release the user from the obligation of own judgement and verification. It must be remembered that the products are
subject to a natural process of wear and aging.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand logotype are registered trademarks of one
of the Emerson family of companies. All other marks are the property of their respective owners. © 2020 Emerson Electric Co.
All rights reserved.
2020-12