3-27
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Characteristics
The WLL directional control valve series of the nominal
size NG10 (CETOP 5) provides variable flow rates.
These valves are available with/without spool position
feedback and electrically controlled by the external dig-
ital amplifier modules VRD350/355 or PWD00A-400.
Typical applications are:
Exact and repeatible adjustment of flow rates, applica-
tions with rapid / slow speed profile and the positioning
of hydraulic drives.
Technical features
• Spool / sleeve design
• High reproducibility from valve to valve
• Low hysteresis
• Progressive flow characteristics for sensitive adjust-
ment of flow rate
• Manual override
• Spool position feedback, optional
3-28
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Ordering Code
W
DC
valve
Spool
type
L
Design
Design
series
E
Seal
NBR
(different
seal
compound
by request)
Please order plug/s separately.
See accessories.
Code
Style
L43
F42
Code
G10P040
G10P060
Spool type
Flow [l/min]
at ∆p 5bar
per metering
edge
40
60
K10P060
60
G10A060
60 / 30
K10A060
60 / 30
Q
B
= Q
A
/2
Q
B
= Q
A
/2
Code
Spool position
feedback
without feedback
with feedback
(plug included)
K
R
3-29
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Technical Data
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Mounting position Optional
Environmental temp. [°C] -20 ... +60
Hydraulics
Pressure medium Hydraulic oil as per DIN 51 524 ... 535, other fluids by request
Viscosity, recommended [mm²/s] 30 ... 80
max. admiss. [mm²/s] 20 ... 380
Oil temperature [°C] 0 ... 60
Filtration Permitted contamination class of to achieve with filter
pressure medium as per NAS 1638 β x = 75
class 7 - 9 X = 10
Mounting pattern DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Operating pressure [bar] Port P, A, B, max. 315 bar, Port T max. 210 bar
Nominal size DIN NG10
CETOP 05
Weight [kg] 6.5
Nominal flow at ∆p=5 bar
per metering edge [l/min] 40 and 60
Static / Dynamic Code K" without spool position feedback Code "R" with spool position feedback
Hysteresis [%] ≤
6 ≤ 0.3
Threshold [%] 0.8 0.3
Sensitivity [%] ≤ 0.4 ≤ 0.2
Response time t for 100% [ms] ≤ 40 ≤ 33
Solenoid
Type G09
Protection class DIN 40050 IP 65
Power consumption [VA] 31.5
Nominal resistance [Ohm] 1.8
Nominal current (100%ED) [A] 3.4
Voltage [V] 9
Electrical connection solenoid EN 175301-803
Wiring
Solenoid coil
1 = coil connection
2 = coil connection
PE = ground potential
3-30
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Characteristic Curves
Dynamic response (WLL43G10* with power amplifier VRD350)
measured at: ±25% amplitude, offset 50%
Flow characteristics
at ∆p = 5bar per metering edge
Spool code G06P* / K06P*
Spool code G06A* / K06A*
3-31
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Characteristic Curves
Operation limits Q = f (
∆∆
∆∆
∆p)
WL*P060*
Step response
Code "K" without spool position feedback
WL*P040*
Code "R" with spool position feedback
3-32
WL_10.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*10*
Catalogue HY11-2500/UK
3
Dimensions
WLF42*
WLL43*
NBR
BK385 4x M6x40 13.6 Nm SK-WLL10FE
DIN 912 12.9
Surface finish