3-21
WL_ 06.PM6.5 RH
Direct Operated Proportional DC Valve
Series WL*06*
Catalogue HY11-2500/UK
3
Technical Data
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Mounting position Optional
Environmental temperature [°C] -20 ... +60
Hydraulics
Pressure fluid Hydraulic oil as per DIN 51 524 ... 535, other fluids by request
Viscosity, recommended [mm²/s] 30 ... 80
max. admiss. [mm²/s] 20 ... 380
Pressure fluid temperature [°C] 0 ... +60
Filtration Permitted contamination class of to achieve with filter
pressure medium as per NAS 1638 β x = 75
class 7 - 9 X = 10
Mounting pattern DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Operating pressure [bar] Port P, A, B, max. 315 bar, Port T max. 210 bar
Nominal size DIN NG06
CETOP 03
Weight [kg] 2.2 (2.5 with LVDT)
Nominal flow at ∆p=5 bar
per metering edge [l/min] 3, 6, 12 and 20
Drain [l/min] see curves
Static / Dynamic Code "K" without spool position feedback Code "R" with spool position feedback
Hysteresis [%] ≤ 4 ≤ 0.3
Threshold [%] 0.5 0.2
Sensitivity [%] ≤ 0.3 ≤ 0.1
Response time t at 100% [ms] ≤ 30 ≤ 20
Solenoid
Type G09
Protection class DIN 40050 IP 65
Power consumption [VA] 17
Nominal resistance [Ohm] 2.2
Nominal current (100%ED) [A] 2.7
Voltage [V] 9
Electrical connection, solenoid EN 175301-803
Elec. connection, pos. indicator M12 / 4pin
EMV conformity, pos. indicator EN 50081-2
EN 50082-1
Note
Standard seal compound is NBR.
Wiring
Solenoid coil Feedback
1 = coil connection
2 = coil connection
PE = ground potential
1 = output, actual spool position
2 = supply (+24V)
3 = GND (0V)