4-8
VB_UK.INDD CM
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Direct Operated Pressure Relief Valve
Series VB
4
Technical Data
Technical data
General
Design Direct operated sequence valve, spool type
Nominal size
NG 06 (CETOP 03 / NFPA D03) NG 10 (CETOP 05 / NFPA D05)
Interface Subplate mounting according to ISO 5781
Mounting position unrestricted
Ambient temperature [°C] -20...+80
Weight [kg] 1.3 3.7
Hydraulic
Max. operating pressure [bar] Port P and A 350
Port T depressurized
Port A and B 315
Port Y depressurized
Pressure stages [bar] 25, 64, 160, 210, 350 64, 125, 210
Nominal flow [l/min] 25 60
Fluid Hydraulic oil according to DIN 51524...525
Fluid temperature [°C] -20...+70
Viscosity recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30...50
20...380
Filtration ISO 4406 (1999) 18/16/13